Skip to main content

3X-Knee: A Novel Technology for 3D Preoperative Planning and Postoperative Evaluation of TKA Based on 2D X-Rays

  • Chapter
  • First Online:

Part of the book series: Advances in Experimental Medicine and Biology ((AEMB,volume 1093))

Abstract

This chapter introduces a solution called ”3X-knee” that can robustly derive 3D models of the lower extremity from 2D long leg standing X-ray radiographs for preoperative planning and postoperative treatment evaluation of total knee arthroplasty (TKA). There are three core components in 3X-knee technology: (1) a knee joint immobilization apparatus, (2) an X-ray image calibration phantom, and (3) a statistical shape model-based 2D-3D reconstruction algorithm. These three components are integrated in a systematic way in 3X-knee to derive 3D models of the complete lower extremity from 2D long leg standing X-ray radiographs acquired in weight-bearing position. More specifically, the knee joint immobilization apparatus will be used to rigidly fix the X-ray calibration phantom with respect to the underlying anatomy during the image acquisition. The calibration phantom then serves two purposes. For one side, the phantom will allow one to calibrate the projection parameters of any acquired X-ray image. For the other side, the phantom also allows

one to track positions of multiple X-ray images of the underlying anatomy without using any additional positional tracker, which is a prerequisite condition for the third component to compute patient-specific 3D models from 2D X-ray images and the associated statistical shape models. Validation studies conducted on both simulated X-ray images and on patients’ X-ray data demonstrate the efficacy of the present solution.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   99.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   129.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Rodricks D, Patil S, Pulido P, Colwell C (2007) Press-fit condylar design total knee arthroplasty. fourteen to seventeen-year follow-up. J Bone Joint Surg Am 89:89–95

    Article  PubMed  Google Scholar 

  2. Vessely M, Whaley A, Harmsen W, Schleck C, Berry D (2006) The Chitranjan Ranawat award: long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties. Clin Orthop Relat Res 452:28–34

    Article  PubMed  Google Scholar 

  3. Kim Y, Park J, Kim J, Park S (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Ortho 38:379–385

    Article  Google Scholar 

  4. Hirschmann M, Konala P, Amsler F, Iranpour F, Friederich N, Cobb J (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 93:629–633

    Article  CAS  PubMed  Google Scholar 

  5. Kobayashi A, Ishii Y, Takeda M, Noguchi H, Higuchi H, Toyabe S (2012) Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty. Comput Aided Surg 17:96–101

    Article  PubMed  Google Scholar 

  6. Trickett R, Hodgson P, Forster M, Robertson A (2009) The reliability and accuracy of digital templating in total knee replacement. J Bone Joint Surg Br 91(8):903–906

    Article  CAS  PubMed  Google Scholar 

  7. Ettinger M, Claassen L, Paes P, Calliess T (2016) 2D versus 3D templating in total knee arthroplasty. Knee 23:149–151

    Article  PubMed  Google Scholar 

  8. Okamoto S, Mizu-uchi H, Okazaki K, Hamai S, Tashiro Y, Nakahara H, Iwamoto Y (2016) Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:229–235

    Article  PubMed  Google Scholar 

  9. De Valk E, Noorduyn J, Mutsaerts E (2016) How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review. Knee Surg Sports Traumatol Arthrosc 24:3517–3528

    Article  PubMed  Google Scholar 

  10. Bäthis H, Perlick L, Tingart M, Lü ring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty: a comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687

    Article  Google Scholar 

  11. Henckel J, Richards R, Lozhkin K, Harris S, Rodriguez y Baena F, Barrett A, Cobb J (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg Br 88:1513–1518

    Article  Google Scholar 

  12. Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243

    Article  PubMed  Google Scholar 

  13. Novosad J, Cheriet F, Petit Y, Labelle H (2004) Three-dimensional 3-D reconstruction of the spine from a single x-ray image and prior vertebra models. IEEE Trans Biomed Eng 51(9):1628–1639

    Article  PubMed  Google Scholar 

  14. Zheng G (2000) Statistically deformable 2D/3D registration for estimating post-operative cup orientation from a single standard AP X-ray radiograph. Ann Biomed Eng 38(9):2910–2927

    Article  Google Scholar 

  15. Yaniv Z, Joskowicz L, Simkin A, Garza-Jinich M, Milgrom C (1998) Fluoroscopic image processing for computer-aided orthopaedic surgery. In: Proceedings of the MICCAI 1998, pp 325–334

    Google Scholar 

  16. Hofstetter R, Slomczykowski M, Sati M, Nolte LP (1999) Fluoroscopy as an imaging means for computer-assisted surgical navigation. Comput Aided Surg 4(2):65–76

    Article  CAS  PubMed  Google Scholar 

  17. Livyatan H, YanivL Z, Joskowicz L (2002) Robust automatic C-Arm calibration for fluoroscopy-based navigation: a practical approach. In: Proceedings of the MICCAI 2002, pp 60–68

    Google Scholar 

  18. Jain A, Fichtinger G (2006) C-arm tracking and reconstruction without an external tracker. In: Proceedings of the MICCAI 2006, pp 494–502

    Google Scholar 

  19. Cheriet F, Laporte C, Kadoury S, Labelle H, Dansereau J (2007) A novel system for the 3-D reconstruction of the human spine and rib cage from biplanar X-ray images. IEEE Trans Biomed Eng 54(7):1356–1358

    Article  CAS  PubMed  Google Scholar 

  20. Schumann S, Dong X, Puls M, Nolte LP, Zheng G (2012) Calibration of C-arm for orthopedic interventions via statistical model-based distortion correction and robust phantom detection. In: Proceedings of the ISBI 2012, pp 1204–1207

    Google Scholar 

  21. Carter CR, Hicken GJ (2005) Device for immobilizing a patient and compressing a patient’s skeleton, joints and spine during diagnostic procedures using an MRI unit, CT scan unit or x-ray unit. US Patent 6,860,272

    Google Scholar 

  22. Schmit BP, Keeton M, Babusis B (2005) Restraining apparatus and method for use in imaging procedures. US Patent 6,882,878

    Google Scholar 

  23. Mitton D, Landry C, Véron S, Skalli W, Lavaste F, De Guise JA (2000) 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes. Med Biol Eng Comput 38(2):133–139

    Article  CAS  PubMed  Google Scholar 

  24. Yu W, Zheng G (2014) Personalized x-ray reconstruction of the proximal femur via a new control point-based 2D-3D registration and residual complexity minimization. VCBM 2014:155–162

    Google Scholar 

  25. Sadowsky O, Chintalapani G, Taylor RH (2007) Deformable 2D-3D registration of the pelvis with a limited field of view, using shape statistics. In: Proceedings of the MICCAI’07, pp 519–526

    Google Scholar 

  26. Ahmad O, Ramamurthi K, Wilson KE, Engelke K, Prince RL, Taylor RH (2010) Volumetric DXA (VXA) – a new method to extract 3D information from multiple in vivo DXA images. J Bone Miner Res 25:2468–2475

    Article  Google Scholar 

  27. Baka N, Kaptein BL, de Bruijne M, van Walsum T, Giphart JE, Niessen WJ, Lelieveldt BP (2011) 2D-3D reconstruction of the distal femur from stereo X-ray imaging using statistical shape models. Med Image Anal 15:840–850

    Article  CAS  PubMed  Google Scholar 

  28. Zheng G (2011) Personalized X-ray reconstruction of the proximal femur via intensity-based non-rigid 2D-3D registration. MICCAI 2011, Part II. LNCS, vol 6982, pp 598–606

    Google Scholar 

  29. Zheng G, Gollmer S, Schumann S, Dong X, Feilkas T, González Ballester MA (2009) A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images. Med Image Anal 13:883–899

    Article  PubMed  Google Scholar 

  30. Hartley R, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge

    Book  Google Scholar 

  31. Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89: 236–243

    PubMed  Google Scholar 

  32. Ettinger M, Claassen L, Paes P, Calliess T (2016) 2D versus 3D templating in total knee arthroplasty. Knee 23:149–151

    Article  PubMed  Google Scholar 

  33. Wybier M, Bossard P (2013) Musculoskeletal imaging in progress: the EOS imaging system. Joint Bone Spine 80(3):238–243

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

This chapter was modified from the paper published by our group in the 7th International conference on Medical Imaging and Augmented Reality (MIAR 2016) (Zheng et al., MIAR2016: 404–414). The related contents were reused with the permission.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guoyan Zheng .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Zheng, G., Alcoltekin, A., Thelen, B., Nolte, LP. (2018). 3X-Knee: A Novel Technology for 3D Preoperative Planning and Postoperative Evaluation of TKA Based on 2D X-Rays. In: Zheng, G., Tian, W., Zhuang, X. (eds) Intelligent Orthopaedics. Advances in Experimental Medicine and Biology, vol 1093. Springer, Singapore. https://doi.org/10.1007/978-981-13-1396-7_8

Download citation

Publish with us

Policies and ethics