Skip to main content

Part of the book series: Springer Proceedings in Physics ((SPPHY,volume 213))

  • 962 Accesses

Abstract

Because of the photocathode has direct influence on the performance of the PMTs, it is important to test the uniformity of the photocathode in the PMTs. In this manuscript, a photocathode uniformity scanning test system of 20 in. large PMTs was designed. This platform used multiple light sources system to test the photocathode uniformity quickly and efficiency. The consistency of the light source in test system is very good. After long time continuous test, the uniformity of light source in this system is less than 3% and the drift less than 0.8% in 1 h, 1.5% in 4 h and 2% in 10 h.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Matsuoka, K.: Development and production of the MCP-PMT for the Belle II TOP counter. Nucl. Instrum. Meth. Phys. Res. A 766, 148–151 (2014)

    Article  ADS  Google Scholar 

  2. Qian, S.: The 20 in. MCP-PMT R&D in China: report of the 16th international workshop on next generation nucleon decay and neutrino detectors (NNN16) (2016)

    Google Scholar 

  3. Wang, Y.: A new design of large area MCP-PMT for the next generation neutrino experiment. Nucl. Instrum. Meth. A 695, 113–117 (2012)

    Article  ADS  Google Scholar 

  4. Xia, J., Qian, S., et al.: A performance evaluation system for photomultiplier tubes. JINST 3023(10), 1–14 (2015)

    Google Scholar 

Download references

Acknowledgements

The MCP-PMT development project has been partially supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDA10010400) and the National Natural Science Foundation of China (Grant Nos. 11175198, 11475209, 11675205 and 11675196).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sen Qian .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ma, Y., Hong, X., Qian, S., Tao, Y., Shi, Y. (2018). Electronics Design for the QE Uniformity Test System. In: Liu, ZA. (eds) Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017. TIPP 2017. Springer Proceedings in Physics, vol 213. Springer, Singapore. https://doi.org/10.1007/978-981-13-1316-5_53

Download citation

Publish with us

Policies and ethics