Abstract
Presently, communication technology has become significantly important. The need for tall towers has been increasing with the requirements for effective communication, particularly for television, radio, GSM, and Internet traffic. Analysis and design of these dynamically sensitive towers are generally governed by the wind loads. Wind excitation induces fluctuating stresses in the members of the tower leading to fatigue damages of the members. In achieving safety with economy for construction, accurate determination of wind load is important. Design wind loads are calculated from the provisions given in the codes and standards. Communication towers subject to vibrations due to wind gusts, which are analyzed using the gust load factor method. This method gives an accurate estimation of wind response of the structure as it considers the resonant component of wind loads. In this paper, microwave lattice tower heights of 21, 30, and 50 m are considered and wind forces are determined using IS 875-1987, IS 875 (Draft), ASCE 7-2010, AS-NZS 1170.2-2011, and HK-2004 design codes and standards. These towers are analyzed for wind velocity of 39 m/s under terrain category-I, terrain category-II, and terrain category-III, and results are compared. It is observed that there is variation in the wind loads and this is primarily due to the difference in definition of wind field features in the compared codes and standards.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Venkateswarlu B, Harikrishna P, Rajan SS, Kumar MSR (1994) Stochastic gust response of microwave lattice towers. Comput Struct 52(5):1031–1041
Harikrishna P, Shanmugasundaram J, Gomathinayagam S, Lakshmanan N (1999) Analytical and experimental studies on the gust response of a 52 m tall steel lattice tower under wind loading. Comput Struct 70:149–160
IS 875 Part-3 (1987) Code of practice for design loads (other than earthquake loads) for buildings and structures
Krishna P, Kumar K, Bhandari NM (2002) IS: 875 (Part3): Wind loads on buildings and structures-proposed draft & commentary. Document No.: IITK-GSDMA-Wind (2002): 02-V5
ASCE 7 (2010) Minimum design loads for buildings and other structures
AS-NZS 1170: Part 2 (2011) structural design actions (wind actions)
HK (2004) code of practice for wind effects in Hong Kong
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Dhandar, N., Vyavahare, A.Y., Nikose, T. (2019). Along Wind Response of Communication Tower. In: Rao, A., Ramanjaneyulu, K. (eds) Recent Advances in Structural Engineering, Volume 2. Lecture Notes in Civil Engineering , vol 12. Springer, Singapore. https://doi.org/10.1007/978-981-13-0365-4_7
Download citation
DOI: https://doi.org/10.1007/978-981-13-0365-4_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-0364-7
Online ISBN: 978-981-13-0365-4
eBook Packages: EngineeringEngineering (R0)