Abstract
The use of a medical device in cardiovascular medicine according to the instructions provides maximum quality and safety, which has been clinically tested and then clinically evaluated. When you use a medical device and do not follow the instructions for use, you use a medical device off-label. Off-label use of a medical device can be seen not as an extension of the clinical use of a medical device, but also as a way of expanding scientific knowledge. Some off-label uses of a medical device provide positive health effects, and some do not. Two examples of off-label use in cardiovascular medicine are presented. While the off-label use of drug-eluting stents is commonly accepted, the off-label use of continuous left ventricular assist devices as continuous flow total artificial hearts provide very poor clinical results. Medical doctors and their patients should know which off-label use method works and which does not.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Beohar N, Davidson CJ, Kip KE, Goodreau L, Vlachos HA, Meyers SN, Benzuly KH, Flaherty JD, Ricciardi MJ, Bennett CL, Williams DO. Outcomes and complications associated with off-label and untested use of drug-eluting stents. Jama 297(18), 1992–2000 (2007).
FDA. Summary from the Circulatory system Devices Panel Meeting – December 7 & 8, 2006. https://www.fda.gov/ohrms/dockets/ac/06/minutes/2006-4253m2-%20Final%201208summ.pdf, last assessed 2017/12/12.
Macku D. The Continuous Flow Total Artificial Heart in Clinical Practice. In: World Congress on Medical Physics and Biomedical Engineering, June 7–12, 2015, Toronto, Canada. Springer International Publishing, 2015. p. 318–321.
Shekar K, Gregory SD, Fraser JF. Mechanical circulatory support in the new era: an overview. Critical Care. 2016;20(1):66.
Cohn WE, Timms DL, Frazier OH. Total artificial hearts: past, present, and future. Nature Reviews Cardiology. 2015;12(10):609–617.
Cohn WE, Handy KM, Parnis SM, Conger JL, Winkler JA, Frazier OH. Eight-year experience with a continuous-flow total artificial heart in calves. ASAIO Journal. 2014;60(1):25–30.
Cohn WE, Winkler JA, Parnis S, Costas GG, Beathard S, Conger J, Frazier OH. Ninety-day survival of a calf implanted with a continuous-flow total artificial heart. ASAIO Journal. 2014;60(1):15–18.
Frazier OH, Cohn WE, Tuzun E, Winkler JA, Gregoric ID. Continuous-flow total artificial heart supports long-term survival of a calf. Texas Heart Institute Journal. 2009;36(6):568–574.
Karimov JH, Fukamachi K, Moazami N, Kobayashi M, Sale S, Mielke N, Sunagawa G, Horvath D, Gao S, Golding LA. In vivo evaluation of the Cleveland Clinic continuous-flow total artificial heart in calves. The Journal of Heart and Lung Transplantation. 2014;33(4):S165–S166.
Loebe M, Bruckner B, Reardon MJ, van Doorn E, Estep J, Gregoric, I, Masud F, Cohn W, Motomure T, Tore-Amione G, Frazier OH. Initial clinical experience of total cardiac replacement with Dual Heartmate-II® Axial Flow Pumps for severe biventricular heart failure. Methodist DeBakey cardiovascular journal. 2011;7(1):40–44.
Frazier OH, Cohn WE. Continuous-Flow Total Heart Replacement Device. Texas Heart Institute Journal. 2012; 39(4):542–546.
Pirk J, Maly J, Szarszoi O, Urban M, Kotulak T, Riha H, Neuzil P, Netuka I. Total artificial heart support with two continuous-flow ventricular assist devices in a patient with an infiltrating cardiac sarcoma. ASAIO Journal. 2013;59(2):178–180.
Czech man with no heart dies after six months. BBC news. BBC Homepage [online]. Retrieved 28.3.2017. From: http://www.bbc.com/news/world-europe-19977958.
Price MJ, Teirstein PS. The off‐versus on‐label use of medical devices in interventional cardiovascular medicine: Clarifying the ambiguity between regulatory labeling and clinical decision‐making, Part 1: PCI. Catheterization and Cardiovascular Interventions. 2008;72(4):500–504.
FDA. “Off-Label” and Investigational Use Of Marketed Drugs, Biologics, and Medical Devices - Information Sheet. https://www.fda.gov/RegulatoryInformation/Guidances/ucm126486.htm.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
The author declares that he has no conflict of interest.
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Macku, D. (2019). Off-label Use of Medical Devices in Cardiovascular Medicine—When the Final Decision About the Safety and Effectiveness Is Needed. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/2. Springer, Singapore. https://doi.org/10.1007/978-981-10-9038-7_1
Download citation
DOI: https://doi.org/10.1007/978-981-10-9038-7_1
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9037-0
Online ISBN: 978-981-10-9038-7
eBook Packages: EngineeringEngineering (R0)