Abstract
In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, miniature implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for electrical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin implants to be massively deployed in tissues. We have also shown that these devices can have bidirectional communication. The aim of this work is to demonstrate a circuit architecture for embedding EMG sensing capabilities in our galvanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant’s ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 µVrms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Pons, J.L. Rehabilitation Exoskeletal Robotics. IEEE Eng. Med. Biol. Mag 29(3), 57–63 (2010).
Weir, R.F., et al. Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording. IEEE Trans. Biomed. Eng. 56(1), 159–171 (2009).
Lowery, M.M., Weir, R.F., Kuiken, T.A. Simulation of Intramuscular EMG Signals Detected Using Implantable Myoelectric Sensors (IMES). IEEE Trans. Biomed. Eng. 53(10), 1926–1933 (2006).
Memberg, W.D., et al. Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia. Arch Phys Med Rehabil. 95(6), 1201–1211 (2014).
Ivorra, A. Remote Electrical Stimulation by Means of Implanted Rectifiers. PLoS One 6(8), e23456 (2011).
Becerra-Fajardo, L., Schmidbauer, M., Ivorra, A. Demonstration of 2-mm-Thick Microcontrolled Injectable Stimulators Based on Rectification of High Frequency Current Bursts. IEEE Trans Neural Syst Rehabil Eng. 25(8), 1343–1352 (2016).
Becerra-Fajardo, L., Ivorra, A.: Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents. In: 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), pp. 545–548. IEEE (2015).
Gabriel, S., Lau, R.W., Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues, Phys. Med. Biol., 41(11), 2271–2293 (1996).
Acknowledgements
This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
The authors declare no conflict of interest.
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Becerra-Fajardo, L., Ivorra, A. (2019). First Steps Towards an Implantable Electromyography (EMG) Sensor Powered and Controlled by Galvanic Coupling. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/3. Springer, Singapore. https://doi.org/10.1007/978-981-10-9023-3_4
Download citation
DOI: https://doi.org/10.1007/978-981-10-9023-3_4
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9022-6
Online ISBN: 978-981-10-9023-3
eBook Packages: EngineeringEngineering (R0)