Abstract
Different fusion techniques are used to treat atlantoaxial instability, including posterior wiring, interlaminar clamps, C1–C2 TAS, the Harms technique, and crossing C2 ILS technique. However, variants of the VA is relatively common; therefore, there is an urgent need for personalized fixation combinations. Unilateral TAS and contralateral C2PS combined with bilateral C1 LMS and C2ILS and TAS combined with bilateral C1LH have been used as alternatives to traditional techniques. The biomechanics of these two fixation combinations have been confirmed. In addition, a combination of bilateral C1LH and C2ILS is considered a good choice in terms of biomechanics and VA safety.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Abbreviations
- C1LH:
-
C1 laminar hook
- C1LMS:
-
C1 lateral mass screw
- C2ILS:
-
C2 intralaminar screw
- C2PS:
-
C2 pedicle screw
- CVJ:
-
Craniovertebral junction
- CT:
-
Computed tomography
- ROM:
-
Range of motion
- TAS:
-
Transarticular screw
- VA:
-
Vertebral artery
References
White AA 3rd, Panjabi MM. The clinical biomechanics of the occipitoatlantoaxial complex. Orthop Clin North Am. 1978;9:867–78.
Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279–84.
McGraw RW, Rusch RM. Atlanto-axial arthrodesis. J Bone Joint Surg (Br). 1973;55:482–9.
Cybulski GR, Stone JL, Crowell RM, et al. Use of Halifax interlaminar clamps for posterior C1-C2 arthrodesis. Neurosurgery. 1988;22:429–31.
Moskovich R, Crockard HA. Atlantoaxial arthrodesis using interlaminar clamps. An improved technique. Spine (Phila Pa 1976). 1992;17:261–7.
Dickman CA, Sonntag VK. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery. 1998;43:275–80; discussion 80-1.
Solanki GA, Crockard HA. Peroperative determination of safe superior transarticular screw trajectory through the lateral mass. Spine (Phila Pa 1976). 1999;24:1477–82.
Richter M, Schmidt R, Claes L, et al. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976). 2002;27:1724–32.
Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26:2467–71.
Melcher RP, Puttlitz CM, Kleinstueck FS, et al. Biomechanical testing of posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976). 2002;27:2435–40.
Zhang P, Liu Q, Xu T, et al. Biomechanical study of 3 atlantoaxial proactive vertebral artery injury prevention fixation combinations. World Neurosurg. 2016;93:293–8.
Kuroki H, Rengachary SS, Goel VK, et al. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery. 2005;56:151–9; discussion 151-9.
Abou Madawi A, Solanki G, Casey AT, et al. Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg (Br). 1997;79:820–3.
Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech. 2004;17:158–62.
Claybrooks R, Kayanja M, Milks R, et al. Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques. Spine J. 2007;7:682–8.
Tan M, Wang H, Wang Y, et al. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine (Phila Pa 1976). 2003;28:888–95.
Huang MJ, Glaser JA. Complete arcuate foramen precluding C1 lateral mass screw fixation in a patient with rheumatoid arthritis: case report. Iowa Orthop J. 2003;23:96–9.
Yamazaki M, Okawa A, Aramomi MA, et al. Fenestration of vertebral artery at the craniovertebral junction in Down syndrome: a case report. Spine (Phila Pa 1976). 2004;29:E551–4.
Yamazaki M, Koda M, Yoneda M, et al. Anomalous vertebral artery at the craniovertebral junction in a patient with Down syndrome. Case report. J Neurosurg Spine. 2004;1:338–41.
Yamazaki M, Koda M, Aramomi MA, et al. Anomalous vertebral artery at the extraosseous and intraosseous regions of the craniovertebral junction: analysis by three-dimensional computed tomography angiography. Spine (Phila Pa 1976). 2005;30:2452–7.
Yamazaki M, Okawa A, Hashimoto M, et al. Abnormal course of the vertebral artery at the craniovertebral junction in patients with Down syndrome visualized by three-dimensional CT angiography. Neuroradiology. 2008;50:485–90.
Takahashi M, Kawanami H, Watanabe N, et al. Fenestration of the extra-cranial vertebral artery. Radiology. 1970;96:359–60.
Kowada M, Yamaguchi K, Takahashi H. Fenestration of the vertebral artery with a review of 23 cases in Japan. Radiology. 1972;103:343–6.
Carella A, Lamberti P, Federico F, et al. Double fenestration of the extracranial vertebral artery. Neuroradiology. 1978;15:193–4.
Krayenbuhl H, Yasargil MG. [The vascular diseases in the region of the basilar & vertebral arteries; an anatomopathological, clinical & neuroradiological study]. Fortschr Geb Rontgenstr Nuklearmed. 1957;87:1–170.
Kazui S, Kuriyama Y, Naritomi H, et al. Estimation of vertebral arterial asymmetry by computed tomography. Neuroradiology. 1989;31:237–9.
Bartels E, Fuchs HH, Flugel KA. Duplex ultrasonography of vertebral arteries: examination, technique, normal values, and clinical applications. Angiology. 1992;43:169–80.
Yuan RY, Yip PK, Liu HM, et al. The value of duplex and continuous wave Doppler sonography for evaluation of the extracranial vertebral arteries: a prospective comparison with angiography. Zhonghua Yi Xue Za Zhi. 1994;53:42–8.
Schoning M, Walter J, Scheel P. Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. Stroke. 1994;25:17–22.
Seidel E, Eicke BM, Tettenborn B, et al. Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults. Stroke. 1999;30:2692–6.
Yamazaki M, Okawa A, Furuya T, et al. Anomalous vertebral arteries in the extra- and intraosseous regions of the craniovertebral junction visualized by 3-dimensional computed tomographic angiography: analysis of 100 consecutive surgical cases and review of the literature. Spine (Phila Pa 1976). 2012;37:E1389–97.
Matsubara T, Mizutani J, Fukuoka M, et al. Safe atlantoaxial fixation using a laminar screw (intralaminar screw) in a patient with unilateral occlusion of vertebral artery: case report. Spine (Phila Pa 1976). 2007;32:E30–3.
D S, Ni B, Lu X, et al. Application of unilateral C2 translaminar screw in the treatment for atlantoaxial instability as an alternative or salvage of pedicle screw fixation. World Neurosurg. 2017;97:86.
Gorek J, Acaroglu E, Berven S, et al. Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine (Phila Pa 1976). 2005;30:1513–8.
Sugimoto Y, Tanaka M, Nakanishi K, et al. Safety of atlantoaxial fusion using laminar and transarticular screws combined with an atlas hook in a patient with unilateral vertebral artery occlusion (case report). Arch Orthop Trauma Surg. 2009;129:25–7.
Guo Q, Liu J, Ni B, et al. C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury. Arch Orthop Trauma Surg. 2011;131:1207–10.
Kamath S. Observations on the length and diameter of vessels forming the circle of Willis. J Anat. 1981;133:419–23.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd. and Shanghai Jiao Tong University Press
About this chapter
Cite this chapter
Zhang, P. (2018). Atlantoaxial Personalized Fixations Including Transarticular Screws + Atlas Hooks. In: Ni, B., Guo, X., Guo, Q. (eds) Atlantoaxial Fixation Techniques. Translational Medicine Research. Springer, Singapore. https://doi.org/10.1007/978-981-10-7889-7_10
Download citation
DOI: https://doi.org/10.1007/978-981-10-7889-7_10
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-7888-0
Online ISBN: 978-981-10-7889-7
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)