Skip to main content

Evaluation of Metal Artifacts from Stainless Steel and Titanium Alloy Orthopedic Screw in Computed Tomography Imaging

  • Conference paper
  • First Online:
  • 313 Accesses

Part of the book series: Lecture Notes in Bioengineering ((LNBE))

Abstract

Artifacts arising from metallic implant had been a concern for Computed Tomography (CT) imaging in obtaining optimal image quality. The main aim of this study was to evaluate the metal artifacts severity from two different types of orthopedics screw and to optimise CT imaging parameters for metallic implants. A water-based abdomen phantom of diameter 32 cm (adult body size) was fabricated using polymethyl methacrylate (PMMA) materials. The fabricated phantom was scanned with dual-energy CT at 80 and 140 kV, and single-energy CT at 120 kV. Two types of orthopedic screws; titanium alloy (grade 5) and stainless steel (grade 316L) was used in this study. A phantom with orthopedics metal screw was scanned at various pitch (0.35, 0.60, 1.20) and slice thickness of 1.0, 3.0, 5.0 mm. The tube current was applied automatically using tube current modulation. In this phantom study, the severity of stainless steel and titanium alloy was analysed. Results showed that the signal-to-noise ratio (SNR) of titanium alloy was higher than the SNR of stainless steel. The optimal image quality of metallic implant was obtained at imaging parameters of pitch at 0.60 and 5.0 mm slice thickness. The use of optimum CT imaging parameters for orthopedic screw resulted in an improved CT image, as the SNR increases. This finding proves that optimum CT imaging parameters are able to reduce the metal artifacts severity on CT images. Therefore, it has potential for improving diagnostic performance in patients with severe metallic artifacts.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   89.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Bamberg F, Dierks A, Nikolaou K, Reiser MF, Becker CR, Johnson TRC (2011) Metal artifacts reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol 21:1424–1429

    Article  Google Scholar 

  2. Meinel FG, Bischoff B, Zhang Q, Bamberg F, Reiser MF, Johnson TR (2012) Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol. Invest Radiol 47:406–414

    Article  Google Scholar 

  3. Johnson TR, Krauss B, Sedlmair M (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517

    Article  Google Scholar 

  4. Yu L, Li H, Mueller J, Kofler JM, Liu X, Primak AN, Fletcher JG, Guimaraes LS, Macedo T, McCollough CH (2009) Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results. Invest Radiol 44:691–696

    Article  Google Scholar 

  5. Zhang X, Wang J, Xing L (2011) Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. Med Phys 38:701–711

    Article  Google Scholar 

  6. Robert M, Michael G, David H (2004) Artifact analysis and reconstruction improvement in helical cardiac cone beam CT. IEEE Trans Med Imaging 23(9):1150–1164

    Article  Google Scholar 

  7. Lee MJ, Kim S, Lee SA, Song HT, Huh YM, Kim DH, Han SH, Suh J (2007) Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. Radiographics 27:791–803

    Article  Google Scholar 

  8. Murakami Y, Kakeda S, Kamada K, Ohnari N, Nishimura J, Ogawa M, Otsubo K, Morishita Y, Korogi Y (2010) Patient safety 64-section multidetector 3D CT angiography: evaluation with a vascular phantom with superimposed bone skull structures. AJNR Am J Neuroradiol 31(4):620–625

    Article  Google Scholar 

  9. Exhibit E, Zhang C, Nicolaou S (2016) Dual-energy computed tomography (DECT): review of key principles and utility in common clinical settings Electronic Presentation Online Syst ECR2016/C-1624

    Google Scholar 

  10. Yusob D, Zukhi J, Tajuddin AA, Zainon R (2017) Evaluation of efficacy of metal artefact reduction technique using contrast media in computed tomography. J Phys Conf Ser 851:012009

    Google Scholar 

  11. Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691

    Article  Google Scholar 

  12. Primak AN, Mccollough CH, Michael R, Zhang RTRJ, Fletcher JG (2006) Relationship between noise, dose, and pitch in cardiac multi-detector row CT 1. Radiographics 26(6):1785–1795

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Zainon .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Yusob, D., Zukhi, J., Tajuddin, A.A., Zainon, R. (2018). Evaluation of Metal Artifacts from Stainless Steel and Titanium Alloy Orthopedic Screw in Computed Tomography Imaging. In: Zainon, R. (eds) 3rd International Conference on Radiation Safety & Security in Healthcare Services. Lecture Notes in Bioengineering. Springer, Singapore. https://doi.org/10.1007/978-981-10-7859-0_5

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-7859-0_5

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-7858-3

  • Online ISBN: 978-981-10-7859-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics