Skip to main content

Measurement of Angular Variation of Cosmic Ray Intensity with Plastic Scintillator Detector

  • Conference paper
  • First Online:
Advanced Detectors for Nuclear, High Energy and Astroparticle Physics

Part of the book series: Springer Proceedings in Physics ((SPPHY,volume 201))

  • 866 Accesses

Abstract

A new and simple technique has been developed using plastic scintillator detectors for the study of angular variation of cosmic ray intensity near the sea level. A systematic study of the characteristics of the plastic scintillator paddle detector has been carried out. The yield uniformity of the detector has also been studied. The details of the measurement and the experimental result are presented in this article.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. A.N. Dmitrieva et al., 29th International Cosmic Ray Conference Pune, vol. 6, 73–76, (2005). [arXiv:hep-ex/0611051v1]

  2. Alexander Mishev, [arXiv: physics/0602120v.2]

  3. S. Cecchini., M. Spurio, Geosci. Instrum. Method. Data Syst. 1, 185–196, (2012). [arXiv:1208.1171v1]

  4. M. Bektasoglu, H. Arslan, Pramana J. Phys. 5, 837–846 (2013)

    Article  ADS  Google Scholar 

  5. ROOT, A Data Analysis Framework, CERN, website: http://www.root.cern.ch

Download references

Acknowledgements

We would like to thank Prof. Sibaji Raha, Prof. Sanjay K. Ghosh, Dr. Rajarshi Ray and Dr. Sidharth K. Prasad for their valuable suggestion and discussions during the course of the study. We would also like to thank Mr. Aritra Mondal of Department of Physics, University of Calcutta, for his help in the study. We are thankful to Bose Institute workshop for all the mechanical work to build the light guide and coupler for light guide. Finally, we are thankful to GSI detector laboratory, Germany, for providing the optical glue, grease, etc., used to build the detector. R. P. Adak acknowledge the support UGC order no—20-12/2009 (ii) EU-IV. S. Biswas acknowledges the support of his Ramanujan Fellowship. This work is also partially supported by the research grant SR/MF/PS-01/2014-BI from Department of Science and Technology, Government of India.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Roy .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Roy, S. et al. (2018). Measurement of Angular Variation of Cosmic Ray Intensity with Plastic Scintillator Detector. In: Biswas, S., Das, S., Ghosh, S. (eds) Advanced Detectors for Nuclear, High Energy and Astroparticle Physics. Springer Proceedings in Physics, vol 201. Springer, Singapore. https://doi.org/10.1007/978-981-10-7665-7_20

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-7665-7_20

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-7664-0

  • Online ISBN: 978-981-10-7665-7

  • eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)

Publish with us

Policies and ethics