Abstract
Good accuracy of continuous glucose monitoring (CGM) technology is a prerequisite for its clinical utility to guide decisions on treatment regimens. This chapter mainly explains how to evaluate the accuracy of CGM technology and its monitoring results. This chapter first introduces the accuracy assessment methods commonly used in clinical practice; then describes the accuracy assessment method for CGM technology, including consensus error grid analysis and continuous error grid analysis; and introduces the criteria of “optimal accuracy” for evaluating CGM data. This chapter also presents the factors affecting the accuracy of CGM technology and puts forward specific approaches for addressing these challenges.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10:622–8.
Zhou J, Bao YQ, Ma XJ, Lu W, Hao YP, Zhou M, Mo YF, Hu C, Xiang KS, Jia WP. Accuracy assessment of continuous glucose monitoring by frequent venous blood collection in patients with type 2 diabetes mellitus. Chin J Diabetes Mellit. 2012;4:523–8. https://doi.org/10.3760/cma.j.issn.1674-5809.2012.09.004.
Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23:1143–8.
Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004;27:1922–8.
Zhou J, Lv X, Mu Y, Wang X, Li J, Zhang X, Wu J, Bao Y, Jia W. The accuracy and efficacy of real-time continuous glucose monitoring sensor in Chinese diabetes patients: a multicenter study. Diabetes Technol Ther. 2012;14:710–8. https://doi.org/10.1089/dia.2012.0014.
Lu W, Zhou J, Ma XJ, Pan JM, Zhu W, Lu FD, Bao YQ, Jia WP. Assessment of the accuracy of continuous glucose monitoring and its correlated factor. West China Med J. 2011;26:811–4.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd. and Shanghai Scientific and Technical Publishers
About this chapter
Cite this chapter
Zhou, J., Jia, W. (2018). Accuracy Assessment of Continuous Glucose Monitoring Technology. In: Jia, W. (eds) Continuous Glucose Monitoring. Springer, Singapore. https://doi.org/10.1007/978-981-10-7074-7_3
Download citation
DOI: https://doi.org/10.1007/978-981-10-7074-7_3
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-7073-0
Online ISBN: 978-981-10-7074-7
eBook Packages: MedicineMedicine (R0)