Control Schemes for Permanent Magnet Synchronous Generator-Based Variable Speed Wind Turbine

  • Rupendra Pachauri
  • Pradeep Rana
  • Yogesh K. Chauhan
  • S. Choudhury
Conference paper
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 624)

Abstract

In this paper, two control schemes such as direct control scheme (DCS) and vector control scheme (VCS) are presented for permanent magnet synchronous generator (PMSG) based adjustable speed wind turbine (WT) system. In DCS, all parameters are obtained in the stator reference frame to invalidate the need of continuous position of rotor. Furthermore, it is analyzed that the DCS acquires numerous advantages over traditional indirect VCS such as torque, flux control lacking any rotor location. It is lesser parameters dependence and sensor less operation. In both the techniques, the DCS can operate underneath fixed and dynamic wind velocity conditions. Both of these control schemes are implemented in MATLAB/Simulink software, and the obtained characteristics are shown which results effective and satisfactory performance.

Keywords

Direct control scheme Vector control scheme Synchronous generator Adaptable speed wind turbine 

References

  1. 1.
    Pachauri, R. K., Chauhan, Y. K.: Assessment of Wind Energy Technology Potential in Indian Context. International Journal of Renewable Energy and Research, 2(2012) 773–780.Google Scholar
  2. 2.
    Muller, S., Deicke, M., Doncker, R. W. D. D.: Doubly Fed Induction Generator System for Wind Turbines. IEEE Transaction on Industrial Applications, 8(2002) 26–33.Google Scholar
  3. 3.
    Mohseni, M., Islam, M. S. M., Masoum, M. A.: Enhanced Hysteresis Based Current Regulators in Vector Control of DFIG Wind Turbine. IEEE Transaction on Power Electronics, 26(2011) 223–234.Google Scholar
  4. 4.
    Haque, M. E., Saw, Y. C., Chowdhury, M. M.: Advanced Control Scheme for an IPM Synchronous Generator Based Gearless Variable Speed Wind Turbine. IEEE Transaction on Sustainable Energy, 5(2014) 354–362.Google Scholar
  5. 5.
    Goodfellow, D., Smith, G. A.: Control Strategy for Variable Speed Wind Energy Recovery. Proc. 8th BWEA Conference Cambridge, 1986, 219–228.Google Scholar
  6. 6.
    Polinder, H., Van der Pijl, F. F. A., Vilder, G. J. D., Tavner, P. J., Comparison of Direct driven and Geared Generator Concepts for Wind Turbines. IEEE Transaction on Energy Conversion, 3(2006) 725–733.Google Scholar
  7. 7.
    Kumar, H., Gupta, A., Pachauri, R. K., Chauhan, Y. K.: PI/FL Based Blade Pitch Angle Control for Wind Turbine Used in Wind Energy Conversion System. in Proc. IEEE Conference on Recent Developments in Control, Automation and Power Engineering, (2015) 1–6.Google Scholar
  8. 8.
    Rao, Y. M., Rao, B. S.: Performance Evaluation of PWM Converter Control Strategy for PMSG Based Variable Speed Wind Turbine. Journal of Engineering Research and Applications, 3(2013) 1000–1006.Google Scholar
  9. 9.
    Pachauri, R. K., Chauhan, Y. K.: Mechanical Control Methods in Wind Turbine Operations for Power Generation. Journal of Automation and Control Engineering, 2(2013) 214–220.Google Scholar
  10. 10.
    Deghan, S. M., Mohamadin, M., Varjani, A. Y.: A New Variable Speed Wind Energy Conversion System Using Permanent Magnet Synchronous Generator and Z-Source Inverter. IEEE Transactions on Energy Conversion, 24(2009) 714–724.Google Scholar
  11. 11.
    Uehara, A., Pratap, A., Goya, T., Senjyu, T., Yona, A., Urasaki, N., Fnabashi, T.: A Coordinate Control Method to Smooth Wind Power Fluctuation of a PMSG Based WECS. IEEE Transaction on Energy Conversion, 26(2011) 550–558.Google Scholar
  12. 12.
    Pachauri, R. K., Kumar, H., Gupta, A., Chauhan, Y. K.: Pitch Angle Controlling of Wind Turbine System Using Proportional-Integral/Fuzzy Logic Controller. In: International Conference on Advanced Computing, Networking and Informatics, 43 (2015) 55–63.Google Scholar
  13. 13.
    Qiao, W., Qu, L., Harley, R. G.: Control of IPM Synchronous Generator for Maximum Wind Power Generation Consideration Magnetic Saturation. IEEE Transaction on Industrial Application, 45(2009) 1095–1105.Google Scholar
  14. 14.
    Pathak, D., Gupta, A., Pachari, R. K., Chauhan, Y. K.: Autonomous Operation of Wind-Battery Hybrid Power System with Intelligent Power Management Capability, International Conference on Intelligent Communication, Control and Devices, Advances in Intelligent. Systems and Computing 479(2016) 317–324.Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2018

Authors and Affiliations

  • Rupendra Pachauri
    • 1
  • Pradeep Rana
    • 2
  • Yogesh K. Chauhan
    • 2
  • S. Choudhury
    • 1
  1. 1.Electronics Instrumentation and Control Engineering Department, College of Engineering StudiesUniversity of Petroleum and Energy StudiesDehradunIndia
  2. 2.Electrical Engineering Department, School of EngineeringGautam Buddha UniversityGreater NoidaIndia

Personalised recommendations