Abstract
Radiology is one kind of diagnostic imaging technology for early diagnosis and prevention of disease that employs X-ray ionizing radiation for imaging of anatomical structure inside the body. The X-ray beam passing through the body gets attenuated by a varying degree depending upon the bone density, soft tissue content, muscle, water content, etc., inside the body and the transmitted X-ray beam is used to form an image of anatomical structure inside the body. At present, around 90,000 X-ray machines are in operation in India. In order to ensure safety of personnel involved in operation of different types of diagnostic radiology equipment as well as safety of the members of public, Atomic Energy Regulatory Board (AERB) exercises the powers conferred by the Atomic Energy Act, 1962 in India. The Mission of AERB is to ensure that safe use of ionizing radiation and nuclear energy in India does not cause any undue risk to the health of people and the environment. AERB issues different types of consents like registration, license for operation of diagnostic radiology facility. Before issue of consent, detailed reviews are carried out, and consent is issued for a specific period of time. Regular, special or surprise inspections are also carried out for verification of radiological safety status in diagnostic radiology facilities. Chairman, AERB, is the competent authority under the Atomic Energy (Radiation Protection) Rules, 2004 and issues time to time directives and notifications prescribing dose limits, radiation warning symbol, etc. AERB publishes several safety related documents like codes, guides, and standards for effective regulation of stakeholders like manufacturers, suppliers, service agencies, and users of diagnostic radiology equipment in the country. It is mandatory to obtain license/registration from AERB for operation of diagnostic radiology equipment. In order to strengthen and streamline the process, AERB has launched a web-based application named e-Licensing of Radiation Applications (e-LORA) for automation of regulatory process. With the increasing number of diagnostic radiology facilities in today’s scenario, effective regulatory control is a challenging task. This paper brings out different modalities of effective and efficient regulation of diagnostic radiology facilities of the country, detailing on the varied experiences acquired in the process, as well as preparedness of the regulatory body in meeting up with the challenges in future.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
- 1.
Memorandum of Understanding between AERB and Department of Health and Family Welfare, covering the terms and conditions agreed upon to participate in regulatory inspections of DR facilities.
- 2.
AERB Safety Manual on “Regulatory Inspection and Enforcement in Radiation Facilities” (No. AERB/RF/SM/G-3).
References
AERB Directive No. 01/2011 vide ref no. CH/AERB/ITSD/125/2011/1507 dated April 27, 2011.
AERB notification on “Prescribed qualifications and experience for personnel in medical X-ray installations”, vide ref no. AERB/RSD/MDX/Sp-order/2012/14316 dated November 26, 2012.
AERB Safety Code on “Regulation of Nuclear and Radiation Facilities” (No. AERB/SC/G) dated August, 2000.
AERB Safety Code on “Radiation Safety in Manufacture, Supply and Use of Medical Diagnostic X-ray Equipment”, No. AERB/RF-MED/SC-3 (Rev.2), 2015.
AERB Safety Guide on “Consenting Process for Radiation Facilities” (No. AERB/RF/SG/G-3 Vols. 1–4), March, 2011.
Atomic Energy Act, No. 33, issued September 15, 1962, amended no. 59 dated December 23, 1986 and vide no. 29 dated September 8, 1987.
Atomic Energy Radiation Protection Rules 1971, amended on September 11, 2004 (GSR 303).
IAEA Safety Fundamentals (IAEA Safety Standards Series No. SF-1), 2006.
NCRP report no. 147 on “Structural Shielding Design for Medical X-Ray Imaging Facilities” (2004).
Sample layout plans and QA formats available at Atomic Energy Regulatory Board official website http://www.aerb.gov.in/AERBPortal/pages/English/X-Ray/X-Ray.jsp. Accessed October 5, 2016.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Guin, A., Mukherjee, S., Pathak, M.K., Sonawane, A.U. (2018). Regulatory Mechanism for Diagnostic Radiology (DR) Facilities in India. In: Ray, P., Maiti, J. (eds) Healthcare Systems Management: Methodologies and Applications. Managing the Asian Century. Springer, Singapore. https://doi.org/10.1007/978-981-10-5631-4_4
Download citation
DOI: https://doi.org/10.1007/978-981-10-5631-4_4
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5630-7
Online ISBN: 978-981-10-5631-4
eBook Packages: Business and ManagementBusiness and Management (R0)