Abstract

Since wrist pulse signals collected by the sensors are often corrupted by artifacts in real situations, many approaches on the wrist pulse preprocessing including pulse denoising and baseline drift removal are introduced for more accurate wrist pulse analysis. However, these scattered methods are incomplete with some limitations when used to preprocess our special pulse data for the clinical applications. This chapter presents a robust signal preprocessing framework for wrist pulse analysis. The cascade filter based on frequency-dependent analysis (FDA) is first introduced to remove the high-frequency noises and to select the significant intervals. Then the curve fitting method is developed to adjust the direction and the baseline drift with minimum signal distortion. Last, the period segmentation and normalization is applied for the feature extraction. The effectiveness of the proposed framework is validated through experiments on actual pulse records with biochemical markers. Both quantitative and qualitative results are given. The results show that the proposed pulse preprocessing framework is effective in extracting more accurate pulse features and practical for wrist pulse analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. S. Lukman, Y. He, and S.-C. Hui, “Computational methods for Traditional Chinese Medicine: A survey,” Computer Methods and Programs in Biomedicine, vol. 88, pp. 283–294, 12, 2007.

    Article  Google Scholar 

  2. L. Xu, K. Wang, D. Zhang, Y. Li, Z. Wan, and J. Wang, “Objectifying researches on traditional Chinese pulse diagnosis,” in Informatica Medica Slovenica, 2003, pp. 56–63.

    Google Scholar 

  3. H. Sorvoja, V. M. Kokko, R. Myllyla, and J. Miettinen, “Use of EMFi as a blood pressure pulse transducer,” Instrumentation and Measurement, IEEE Transactions on, vol. 54, pp. 2505–2512, 2005.

    Google Scholar 

  4. M. Nitzan, “Automatic noninvasive measurement of arterial blood pressure,” Instrumentation & Measurement Magazine, IEEE, vol. 14, pp. 32–37, 2011.

    Google Scholar 

  5. C.-H. Luo, Y.-F. Chung, C.-S. Hu, C.-C. Yeh, X.-C. Si, D.-H. Feng, Y.-C. Lee, S.-I. Huang, S.-M. Yeh, C.-H. Liang, “Possibility of quantifying TCM finger-reading sensations: I. Bi-Sensing Pulse Diagnosis Instrument," European Journal of Integrative Medicine, vol. 4, pp. e255-e262, 9, 2012.

    Google Scholar 

  6. P. Wang, W. Zuo, and D. Zhang, “A Compound Pressure Signal Acquisition System for Multichannel Wrist Pulse Signal Analysis,” Instrumentation and Measurement, IEEE Transactions on , vol.63, no.6, pp.1556,1565, June 2014

    Google Scholar 

  7. M. Aboy, J. McNames, T. Tran, D. Tsunami, M. S. Ellenby, and B. Goldstein, “An automatic beat detection algorithm for pressure signals,” Biomedical Engineering, IEEE Transactions on, vol. 52, pp. 1662–1670, 2005.

    Article  Google Scholar 

  8. H. M. Haqqani, J. B. Morton, and J. M. Kalman, “Using the 12-Lead ECG to Localize the Origin of Atrial and Ventricular Tachycardias: Part 2—Ventricular Tachycardia,” Journal of cardiovascular electrophysiology, vol. 20, pp. 825–832, 2009.

    Article  Google Scholar 

  9. D.-Y. Zhang, W.-M. Zuo, D. Zhang, H.-Z. Zhang, and N.-M. Li, “Wrist blood flow signal-based computerized pulse diagnosis using spatial and spectrum features,” Journal of Biomedical Science and Engineering, vol. 3, p. 361, 2010.

    Article  Google Scholar 

  10. C. T. Lee and L. Y. Wei, “Spectrum analysis of human pulse,” Biomedical Engineering, IEEE Transactions on, pp. 348–352, 1983.

    Article  Google Scholar 

  11. E. J. Ciaccio and G. M. Drzewiecki, “Tonometric Arterial Pulse Sensor with Noise Cancellation,” Biomedical Engineering, IEEE Transactions on, vol. 55, pp. 2388–2396, 2008.

    Google Scholar 

  12. C. Xia, Y. Li, J. Yan, Y. Wang, H. Yan, R. Guo, et al., “A practical approach to wrist pulse segmentation and single-period average waveform estimation,” in BioMedical Engineering and Informatics, 2008. BMEI 2008. International Conference on, 2008, pp. 334–338.

    Google Scholar 

  13. H.-T. Wu, C.-H. Lee, A.-B. Liu, W.-S. Chung, C.-J. Tang, C.-K. Sun, et al., “Arterial stiffness using radial arterial waveforms measured at the wrist as an indicator of diabetic control in the elderly,” Biomedical Engineering, IEEE Transactions on, vol. 58, pp. 243–252, 2011.

    Google Scholar 

  14. M. Blanco-Velasco, B. Weng, and K. E. Barner, “ECG signal denoising and baseline wander correction based on the empirical mode decomposition,” Computers in biology and medicine, vol. 38, pp. 1–13, 2008.

    Article  Google Scholar 

  15. M. Mneimneh, E. Yaz, M. Johnson, and R. Povinelli, “An adaptive Kalman filter for removing baseline wandering in ECG signals,” in Computers in Cardiology, 2006, 2006, pp. 253–256.

    Google Scholar 

  16. L. Xu, D. Zhang, and K. Wang, “Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms,” Biomedical Engineering, IEEE Transactions on, vol. 52, pp. 1973–1975, 2005.

    Article  Google Scholar 

  17. K. Wang, L. Xu, L. Wang, Z. Li, and Y. Li, “Pulse baseline wander removal using wavelet approximation,” in Computers in Cardiology, 2003, 2003, pp. 605–608.

    Google Scholar 

  18. D. Wang and D. Zhang, “Analysis of pulse waveforms preprocessing,” in Computerized Healthcare (ICCH), 2012 International Conference on, 2012, pp. 175–180.

    Google Scholar 

  19. L. Xu, D. Zhang, K. Wang, N. Li, and X. Wang, “Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter,” Computers in Biology and Medicine, vol. 37, pp. 716–731, 5, 2007.

    Article  Google Scholar 

  20. Y. Chen, L. Zhang, D. Zhang, and D. Zhang, “Wrist pulse signal diagnosis using modified Gaussian models and Fuzzy C-Means classification,” Medical engineering & physics, vol. 31, pp. 1283–1289, 2009.

    Article  Google Scholar 

  21. A. D. S. Ferreira, “Resonance phenomenon during wrist pulse-taking: A stochastic simulation, model-based study of the ‘pressing with one finger’ technique,” Biomedical Signal Processing and Control, vol. 8, pp. 229–236, 5, 2013.

    Article  Google Scholar 

  22. Y. Chen, L. Zhang, D. Zhang, and D. Zhang, “Computerized Wrist Pulse Signal Diagnosis Using Modified Auto-Regressive Models,” Journal of Medical Systems, vol. 35, pp. 321–328, 2011.

    Article  Google Scholar 

  23. D. Zhang, D. Zhang, and Y. Zheng, “Wavelet based analysis of Doppler ultrasonic wrist-pulse signals,” in BioMedical Engineering and Informatics, 2008. BMEI 2008. International Conference on, 2008, pp. 539–543.

    Google Scholar 

  24. L. Liu, W. Zuo, D. Zhang, N. Li, and H. Zhang, “Combination of heterogeneous features for wrist pulse blood flow signal diagnosis via multiple kernel learning,” Information Technology in Biomedicine, IEEE Transactions on, vol. 16, pp. 598–606, 2012.

    Google Scholar 

  25. R. J. Martis, U. R. Acharya, and L. C. Min, “ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform,” Biomedical Signal Processing and Control, vol. 8, pp. 437–448, 9, 2013.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Zhang, D., Zuo, W., Wang, P. (2018). Optimized Preprocessing Framework for Wrist Pulse Analysis. In: Computational Pulse Signal Analysis. Springer, Singapore. https://doi.org/10.1007/978-981-10-4044-3_6

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-4044-3_6

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-4043-6

  • Online ISBN: 978-981-10-4044-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics