As digital technology is more and more used in nuclear power plants, the electromagnetic compatibility issues between new digital device and the plant environment are increasingly prominent. This paper is aiming at the dither of control valve in pressurized water reactor project, which is causing by the electromagnetic compatibility issues. And this paper mainly describes the experience of working process and the solving program of failure eliminating. First it introduces the installation condition and operating principle of the valve, then it analyzes the possible causes by using fault tree and find the root cause by site investigation. The root cause of the malfunction is that the feedback signal of valve position is disturbed by an interferential signal about 32 kHz. At last, this paper provides two kinds of program to solve the problem, one is grounding directly and another is grounding with capacitance.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Zhou Hongyan (2001) Research on intelligent electric valve positioner. Sichuan University.
Zhang Lei (2001) Research on intelligent valve positioner. Luoyang Institute of Technology.
Chen Dedao (2015) An huping Numerical Control Machine Fault Diagnosis Based on Fuzzy Fault Tree. J Machine Tool & Hydraulics 177–178.
Pan Bo, Jiang Tongmin (2012) The structure of the corrosion damage of aircraft Fuzzy comprehensive evaluation based on fault tree. J Beijing University of Aeronautics and Astronautic 38–42.
Wu Weizhi, Cheng Shengchang, Yuan Wenzhong (2012) Power Plant Unit 4 DCS system analog signal processing analysis of wide fluctuations. J Thermal Power Generation.
Wang Qinghai (2012) PLC control system grounding jamming technology. J Automation, 173–174.
Machang (2009) Talking about the PLC control system grounding jamming technology. J Dragons Technology and Management.
Wang Qingliang (2012) Single-phase ground fault analysis and line selection. M China Electric Power Press.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Xi, Ch., Zhang, Lq., Tian, Y. (2017). Analyzing and Processing the Malfunction of Control Valve Dithering in PWR Nuclear Power Plant. In: Xu, Y. (eds) Nuclear Power Plants: Innovative Technologies for Instrumentation and Control Systems. SICPNPP 2016. Lecture Notes in Electrical Engineering, vol 400. Springer, Singapore. https://doi.org/10.1007/978-981-10-3361-2_7
Download citation
DOI: https://doi.org/10.1007/978-981-10-3361-2_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-3360-5
Online ISBN: 978-981-10-3361-2
eBook Packages: EnergyEnergy (R0)