Skip to main content

Analysis of CPU Redundant Configuration for the Safety DCS of NPP

  • Conference paper
  • First Online:
Book cover Nuclear Power Plants: Innovative Technologies for Instrumentation and Control Systems (SICPNPP 2016)

Abstract

Safety digital control system (DCS) has been used in nuclear power plant (NPP). DCS provides different control, monitoring and operating means for nuclear power plant (NPP). It is necessary to consider the redundant configuration for CPU, because CPU is one kind of the important equipment of safety DCS which need to accord with the single failure criterion and reliability requirement. Based on the project technical plan, the paper analyzes the different redundant configuration for CPU of safety DCS system and gives some thoughts on engineering practice. It will be benefit to the following project practice.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. General Administration of Quality Supervision Inspection and Quarantine of the People’s Republic of China, Standardization Administration of the People’s Republic of China (2008). Application of the single failure criterion to safety systems in nuclear power plant [S], GB/T 13626. Beijing

    Google Scholar 

  2. General Administration of Quality Supervision Inspection and Quarantine of the People’s Republic of China, Standardization Administration of the People’s Republic of China (2008). Applicable criteria for digital computers in safety systems of nuclear power plants [S], GB/T 13629. Beijing

    Google Scholar 

  3. International Electrotechnical Commission (2011) Nuclear power plants – Instrumentation and control for systems important to safety - General requirements for systems [S], IEC 61513

    Google Scholar 

  4. NSSS (2004) Safety of Nuclear Power Plants: Design [Z], HAF 102. Beijing

    Google Scholar 

  5. NSSS (2004) Nuclear power plant protection system and related facilities [Z], HAD 102/10. Beijing

    Google Scholar 

  6. NSSS (2004) Safety related instrumentation and control system for nuclear power plant [Z], HAD 102/14. Beijing

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to You-ran Li .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Li, Yr., Sun, W., Zhou, L., Zhang, Lq. (2017). Analysis of CPU Redundant Configuration for the Safety DCS of NPP. In: Xu, Y. (eds) Nuclear Power Plants: Innovative Technologies for Instrumentation and Control Systems. SICPNPP 2016. Lecture Notes in Electrical Engineering, vol 400. Springer, Singapore. https://doi.org/10.1007/978-981-10-3361-2_4

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-3361-2_4

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-3360-5

  • Online ISBN: 978-981-10-3361-2

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics