Advertisement

Refrigeration, Ventilation, and Air Conditioning

  • David R. Storm

Abstract

Probably more than any other aspect of winemaking, the maintenance of product temperature from fermentation through final warehouse storage is the most important process parameter in the vinification of high-quality wines. The rather restrictive ideal temperature regime of 55–65°F (13–18°C) can be achieved through a combination of means. What follows is an overview of the planning, design, and operation of the heating, ventilating, air conditioning, and refrigeration (HVAC&R) systems as seen from a winery perspective. Heating of winery spaces has been reduced in scope in this chapter because, except for administrative and laboratory spaces, heating is routinely handled by the mechanical designers and/or air-conditioning professionals. Heating is referred to incidentally in sections which discuss winery solar orientation and the Carnot refrigeration cycle operating as a heat pump. Insofar as possible, related topics that are or will produce a significant technical change or economic impact on HVAC&R systems now or in the near future will be highlighted. A selected list of references is given at the end of this chapter, including an excellent treatment of winery refrigeration technology, as practiced in Australia (42).

Keywords

Heat Pump Ventilation System Refrigeration System Sparkling Wine Pipe Size 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 42.
    White, R., Adamson, B., and Rankine, B. 1989 Refrigeration for Winemakers. Adelaide, S. Australia: Hyde Park Press.Google Scholar
  2. 43.
    Johnson, H. 1980 World Atlas of Wine. London: Mitchell Beazley Publ.Google Scholar
  3. 44.
    Boulton, R.B., Singleton, V.L., Bisson, L., Kunkee, R.E. 1996 Principles and Practices of Winemaking. New York: Chapman & Hall.CrossRefGoogle Scholar
  4. 45.
    Duffy, G. 1992. Thermal storage emphasis shifts to saving energy. Engineered Systems, July–Aug.Google Scholar
  5. 46.
    — 1991. Cold air distribution with ice storage. 1991. Proceedings of the Electrical Power Research Institute, No. 2038.Google Scholar
  6. 47.
    McQuiston, F.C. and Parker, J.D. 1977 Heating, Ventilating and Air Conditioning Analysis and Design. New York: John Wiley and Sons.Google Scholar
  7. 48.
    Bukowski, J. 1993. The many faces of industrial refrigeration. Consulting Specifying Engineer 14(4).Google Scholar
  8. 49.
    — 1990. Recycling programs for auto air conditioners and other industries using CFC’s. Pollut. Eng. 56-57.Google Scholar
  9. 50.
    — 1991. ASHRAE Handbook: HVAC Applications. Atlanta, GA: American Society of Heating, Refrigerating and Air Conditioning Engineers, Table 3, p. 33.3.Google Scholar
  10. 51.
    Lee, D. 1992 Potential for Recycling CFC’s. Washington, DC: USEPA Reg. and Analysis Branch; Global Change Division, Office of Atmospheric and Indoor Air Programs.Google Scholar
  11. 52.
    — 1989. Refrigeration, Air Conditioning, and Heat Pumps—Technical Options Report. United Nations Environment Programme, Paris, Tables 9.1 and 9.2, p. 80.Google Scholar
  12. 53.
    Meckler, G. 1993. Integrated IAQ-CFC retrofit saves energy. Consulting Specifying Engineer..Google Scholar
  13. 54.
    Amerine, M.A. and Joslyn, M.A. 1973 Table Wines: The Technology of Their Production. Berkeley: University of California Press.Google Scholar
  14. 55.
    Rieger, T. 1994. Tank mixers and pumpover devices. Vineyard Winery Management. 34-39.Google Scholar
  15. 56.
    — 1992. Airborne Contaminants. California General Industrial Safety Orders, Sect. 5155, Title 8. Cal. Code of Regulations.Google Scholar
  16. 57.
    Baumeister, T. 1967 Marks’ Mechanical Engineers Handbook. New York: McGraw Hill Book Co., p. 550.Google Scholar
  17. 58.
    Kashab, A.M. 1978 Heating, Ventilating and Air Conditioning. New York: McGraw-Hill Books.Google Scholar
  18. 59.
    Kashab, A.M. 1993. Heavy Construction Cost Guide. Leonard McMahon, Inc, Publisher, Quincy, MA.Google Scholar
  19. 60.
    — 1982. ASHRAE Handbook of Fundamentals, 5th ed. Atlanta, GA: American Society of Refrigeration and Air Conditioning Engineers.Google Scholar
  20. 61.
    — 1975. Energy Insulation Standards. Cal. Admin. Code, Title 25, Chapter 1, Subchapter 1, Article 5 (as amended).Google Scholar
  21. 62.
    Kratowicz, R. 1993. Which insulation thickness? An optimization principle. Plant Services 14(9): 13–18.Google Scholar
  22. 63.
    — 1976. Energy Design Manual. State of California Department of Housing and Community Development, Div. of Codes and Standards, 1976 Ed.Google Scholar
  23. 64.
    Tinsley, R.W. and Kegel, R.A. 1993. Pipe insulation conserves energy and cuts costs. Consulting Specifying Engineer. 13(5):68–72.Google Scholar

Copyright information

© Springer Science+Business Media Dordrecht 1997

Authors and Affiliations

  • David R. Storm
    • 1
  1. 1.Storm Engineering, Inc.USA

Personalised recommendations