The microbiological pollution of buildings may occur as a result of contamination of incoming air, of the airconditioning system itself, of water containing structures within the building, of the building materials themselves and may arise from the occupants either by person to person contact or circulated via the ventilation system. The types of disease produced in man by microbiological pollution include infectious disease, allergic disease and toxic reactions. This article will consider each of these disease groups and their relationship to buildings.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Riley, E.C., Murphy, G., Rileyf R.L., (1978). ‘Airborne spread of measles in a suburban elementary school’, Am. J. Epidemiol, 107,421–432.

    PubMed  CAS  Google Scholar 

  2. Brundage, J.P., Scott, R. McN., Lednar, W.M., et al., (1988). ‘Building-associated risk of febrile acute respiratory diseases in army trainees’, J.A.M.A., 259, 2108–2112.

    Article  PubMed  CAS  Google Scholar 

  3. Honk, V.N., Kent, D.C., Baker, J.H., Sorenson, K., (1968). ‘The epidemiology of tuberculosis infection in a closed environment’, Arch. Environ. Health, 16,26–35.

    Google Scholar 

  4. Fraser, D.W., Tsai, T.R., Orenstein, W., et al., (1977). ‘Legionnaires1 disease. Description of an epidemic pneumonia’. N.Engl. J. Med., 297,1189–1197.

    Article  PubMed  CAS  Google Scholar 

  5. Dondero, T.J., Rendtorff, R.C., Mallinson, CF., et al., (1980). ‘An outbreak of Legionnaire’s Disease associated with a contaminated airconditioning cooling tower’, N.Engl. J. Med., 302,365–370.

    Article  PubMed  Google Scholar 

  6. Band, J.D., LaVenture, M., Davis, J.P., et al., (1981). ‘Epidemic Legionnaires’ Disease. Airborne transmission down a chimney’, J.A.M.A., 245, 2404–2407.

    Article  PubMed  CAS  Google Scholar 

  7. Badenoch, J., (1985). ‘First report of the committee of inquiry into the outbreak of Legionnaires’ disease in Stafford in April 1985’. Her Majesty’s Stationery Office, London.

    Google Scholar 

  8. ‘Report of an ad-hoc committee. (1986) Outbreak of legionellosis in a community’, Lancet, ii, 380–383.

    Google Scholar 

  9. Bhopal, R.S., Fallon, R.J., Buist, E.C., Black, R.J., Urquhart, J.D., (1991). ‘Proximity of the home to a cooling tower and the risk of non-outbreak legionnaires’ disease’, Brit. Med. J., 302, 378–383.

    Article  PubMed  CAS  Google Scholar 

  10. Tobin, J.O’H., Dunnill, M.S., French, M. et al.(1980). ‘Legionnaires’ disease in a transplant unit: isolation of the causative agent from shower baths’, Lancet, ii, 118–121.

    Article  Google Scholar 

  11. Tobin, J.O’H., Bartlett, C.L.R., Waitkins, S.A., et al., (1981). ‘Legionnaires’ disease: further evidence to implicate water storage and distribution systems as sources’, Brit. Med. J., 282, 573.

    Article  CAS  Google Scholar 

  12. Glick, T.H., Gregg, M.B., Berman, B., et al., (1978). ‘Pontiac fever. An epidemic of unknown etiology in a health department: 1. Clinical and epidemiological aspects’. Am. J. Epidemiol., 107, 149–160.

    PubMed  CAS  Google Scholar 

  13. Sarubbi, F.A., Kopf, H.B., Wilson, M.B., et al.(1982). ‘Increased recovery of Aspergillus flavus from respiratory specimens during hospital construction’, Am. Rev. Respir. Dis., 125(1), 33–38.

    PubMed  Google Scholar 

  14. Kyriakides, G.K., Zinneman, H.H., Hallf, W.H., (1976). ‘Immunological monitoring and aspergillosis in renal transplant patients’. Am. J. Surg., 131, 246–252.

    Article  PubMed  CAS  Google Scholar 

  15. Solomon, W.R., (1970) ‘Fungus aerosols arising from cold mist vaporizers’, J. Allergy Clin. Immunol., 54,222–228.

    Article  Google Scholar 

  16. Finnegan, M.J., Pickering, C.A.C., (1984). ‘Work related asthma and humidifier fever in airconditioned buildings’, in B. Berglund, T. Lindvall and J. Sundell (eds.), Proceedings of the 3rd International Conference on Indoor Air Quality and Climate, vol. 1: Recent Advances in Health Sciences and Technology. Swedish Council for Building Research, Stockholm, pp. 257–262.

    Google Scholar 

  17. Bürge, P.S., Finnegan, M.J., Horsfield, N., et al., (1985). ‘Occupational asthma in a factory with a contaminated humidifier’, Thorax, 40, 248–254.

    Article  PubMed  Google Scholar 

  18. Banaszak, E.F., Thiede, W.H., Fink, J.N., (1970). ‘Hypersensitivity pneumonitis due to contamination of an airconditioner’. N.Engl. J. Med., 283(6), 271–276.

    Article  PubMed  CAS  Google Scholar 

  19. Arnow, P.M., Fink, J.N., Schieuter, D.P. (1978). ‘Early detection of hypersensitivity in office workers’, Am. J. Med., 64, 236–241.

    Article  PubMed  CAS  Google Scholar 

  20. Sweet, L.C., Anderson, J.A., Cailles, Q.C., Coates, E.O., (1971). ‘Hypersensitivity pneumonitis related to a home furnace humidifier’, J, Allergy Clin. Immunol., 48, 171–179.

    Article  CAS  Google Scholar 

  21. Fink, J.N., Banaszak, E.F., Thiede, W.H., Barboriak, J.J., (1971). ‘Interstitial pneumonitis due to hypersensitivity to an organism contaminating a heating system’, Ann. Int. Med.,74,80–83.

    PubMed  CAS  Google Scholar 

  22. Tourville, D.R., Weiss, W.I., Wertlake, P.T., Loudemann, G.M., (1972). ‘Hypersensitivity pneumonitis due to contamination of home humidifier’, J. Allergy Clin. Immunol., 49, 245–251.

    Article  PubMed  CAS  Google Scholar 

  23. Hodges, G.R., Fink, J.N., Schlueter, D.P., (1974). ‘Hypersensitivity pneumonitis caused by a contaminated cool-mist vaporizer’, Ann. Int. Med., 80, 501–504.

    PubMed  CAS  Google Scholar 

  24. Marinkovich, V.A., Hill, A., (1975). ‘Hypersensitivity alveolitis’, J.A.M.A., 231, 944–947.

    Article  PubMed  CAS  Google Scholar 

  25. Banaszak, E.F., Barboriak, J., Fink, J.N., et al., (1974). ‘Epidemiologic studies relating thermophilic fungi and hypersensitivity lung syndromes’, Am. Rev. Respir. Dis., 110, 585–591.

    PubMed  CAS  Google Scholar 

  26. Robertson, A.S., Bürge, P.S., Weiland, A., (1985). ‘Extrinsic allergic alveolitis due to antigen from a humidifier at 15°C’, Thorax, 40(3), 229(abstr).

    Google Scholar 

  27. Metzger, W.J., Patterson, R., Fink, J., Semerdjian, R., Roberts, M., (1976). ‘Sauna-taker s Disease. Hypersensitivity pneumonitis due to contaminated water in a home sauna’, J.A.M.A., 236, 2209–2211.

    Article  PubMed  CAS  Google Scholar 

  28. Jacobs, R.L., Thorner, R.E., Holcomb, J.R. et al., (1986). ‘Hypersensitivity pneumonitis caused by Cladosporium in an enclosed hot-tub area’, Ann. Int. Med., 105, 204–206.

    PubMed  CAS  Google Scholar 

  29. Fergusson, R.J., Milne, L.J.R., Crompton, G.K. (1984). ‘Penecillium allergic alveolitis: faulty installation of central heating’, Thorax, 39, 294–298.

    Article  PubMed  CAS  Google Scholar 

  30. Rose, C.S., Newman, L.S., Martyny, J.W. et al., (1991). ‘Outbreak of hypersensitivity pneumonitis in an indoor swimming pool: clinical, physiological, radiographic, pathologic, lavage and environmental findings’, Am. Rev. Respir. Dis., 143, A315.

    Google Scholar 

  31. Muittari, A., Kuusisto, P., Virtanen, P. et al., (1980). ‘An epidemic of extrinsic allergic alveolitis caused by tap water’, Clin. Allergy, 10, 77–90.

    Article  PubMed  CAS  Google Scholar 

  32. Friend, J.A.R., Gaddie, J., Palmer, K.N.V., Pickering, C.A.C., Pepys, J., (1977). ‘Extrinsic allergic alveolitis and contaminated cooling-water in a factory machine’, Lancet, i, 297–300.

    Article  Google Scholar 

  33. Pestalozzi, C. (1959). ‘Febrile Gruppenerkrankungen in einer Modellschreinerei durch Inhalation von mit Schimmelpilzen Kontaminiertem Befeuchterwasser (‘Befeuchterfieber’)’, Schweiz. Med. Wochenschr., 89(27), 710–713.

    PubMed  CAS  Google Scholar 

  34. ‘Her Majesty’s Chief Inspector of Factories Annual Report for 1969’. H.M.S.O.: 1969:72–74.

    Google Scholar 

  35. Pickering, C.A.C., Moore, W.K.S., Lacy, J., et al., (1976). ‘Investigation of a respiratory disease associated with an airconditioning system’, Clin. Allergy, 6, 109–118.

    Article  PubMed  CAS  Google Scholar 

  36. Parrott, W.F., Blyth, W., (1980). ‘Another causal factor in the production of humidifier fever’, J. Soc. Occup. Med., 30, 63–68.

    Article  PubMed  CAS  Google Scholar 

  37. Rylander, R., Haglind, P., Lundholm, M., Mattsby, I., Stenqvist, K., (1978). ‘Humidifier fever and endotoxin exposure’, Clin. Allergy,8,511–516.

    Article  PubMed  CAS  Google Scholar 

  38. NewmanTaylor, A., Pickering, C.A.C., Turner-Warwick, M. (1978). ‘Respiratory allergy to a factory humidifier contaminant presenting as pyrexia of undetermined origin’, Brit. Med. J., 11,94–95.

    Google Scholar 

  39. Campbell, I.A., Cockcroft, A.E., Edwards, J.H., Jones, M., (1979). ‘Humidifier fever in an operating theatre’, Brit. Med. J., 2, 1036–1037.

    Article  PubMed  CAS  Google Scholar 

  40. Anderson, K., Watt, A.D., Sinclair, D. et al., (1989). ‘Climate, intermittent humidification, and humidifier fever’, Brit. J. Ind. Med., 46, 671–674.

    CAS  Google Scholar 

  41. Edwards, J.H., Griffiths, A.J., Mullins, J., (1976). ‘Protozoa as sources of antigen in humidifier fever’, Nature, 264, 438–439.

    Article  PubMed  CAS  Google Scholar 

  42. Finnegan, M.J., Pickering, C.A.C., Davies, P.S., Austwick, P.K.S., Warhurst, D.C., (1987). ‘Amoebae and humidifier’. Clin. Allergy, 17, 235–242.

    Article  PubMed  CAS  Google Scholar 

  43. Finnegan, M.J., Pickering, C.A.C, Davies, P.S., Austwick, P.K.C., (1985). ‘Factors affecting the development of precipitating antibodies in workers exposed to contaminated humidifiers’, Clin. Allergy, 15, 281–292.

    Article  PubMed  CAS  Google Scholar 

  44. Croft, W.A., Jarvis, B.B., Yatawara, C.S. (1986). ‘Airborne outbreak of trichothecene toxicosis’, Atmospheric Envir., 20, 549–552.

    Article  Google Scholar 

  45. Nexo, E., Skov, P.G., Gravesen, S., (1983). ‘Extreme fatigue and malaise — a syndrome caused by badly cleaned wall--to-wall carpets?’ Ecology of Disease, 2, 415–418.

    PubMed  CAS  Google Scholar 

  46. Harrison, J., Pickering, C.A.C, Faragher, E.B. et al. (in press). ‘An investigation of the relationship between microbial and particulate indoor air pollution and the sick building syndrome’, Respiratory Medicine.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1992 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Pickering, C.A.C. (1992). The Effects of Microbiological Pollution in Buildings — Results of Building Investigations. In: Knöppel, H., Wolkoff, P. (eds) Chemical, Microbiological, Health and Comfort Aspects of Indoor Air Quality — State of the Art in SBS. Eurocourses: Chemical and Environmental Science, vol 4. Springer, Dordrecht. https://doi.org/10.1007/978-94-015-8088-5_18

Download citation

  • DOI: https://doi.org/10.1007/978-94-015-8088-5_18

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-90-481-4152-4

  • Online ISBN: 978-94-015-8088-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics