Abstract
The microbiological pollution of buildings may occur as a result of contamination of incoming air, of the airconditioning system itself, of water containing structures within the building, of the building materials themselves and may arise from the occupants either by person to person contact or circulated via the ventilation system. The types of disease produced in man by microbiological pollution include infectious disease, allergic disease and toxic reactions. This article will consider each of these disease groups and their relationship to buildings.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Riley, E.C., Murphy, G., Rileyf R.L., (1978). ‘Airborne spread of measles in a suburban elementary school’, Am. J. Epidemiol, 107,421–432.
Brundage, J.P., Scott, R. McN., Lednar, W.M., et al., (1988). ‘Building-associated risk of febrile acute respiratory diseases in army trainees’, J.A.M.A., 259, 2108–2112.
Honk, V.N., Kent, D.C., Baker, J.H., Sorenson, K., (1968). ‘The epidemiology of tuberculosis infection in a closed environment’, Arch. Environ. Health, 16,26–35.
Fraser, D.W., Tsai, T.R., Orenstein, W., et al., (1977). ‘Legionnaires1 disease. Description of an epidemic pneumonia’. N.Engl. J. Med., 297,1189–1197.
Dondero, T.J., Rendtorff, R.C., Mallinson, CF., et al., (1980). ‘An outbreak of Legionnaire’s Disease associated with a contaminated airconditioning cooling tower’, N.Engl. J. Med., 302,365–370.
Band, J.D., LaVenture, M., Davis, J.P., et al., (1981). ‘Epidemic Legionnaires’ Disease. Airborne transmission down a chimney’, J.A.M.A., 245, 2404–2407.
Badenoch, J., (1985). ‘First report of the committee of inquiry into the outbreak of Legionnaires’ disease in Stafford in April 1985’. Her Majesty’s Stationery Office, London.
‘Report of an ad-hoc committee. (1986) Outbreak of legionellosis in a community’, Lancet, ii, 380–383.
Bhopal, R.S., Fallon, R.J., Buist, E.C., Black, R.J., Urquhart, J.D., (1991). ‘Proximity of the home to a cooling tower and the risk of non-outbreak legionnaires’ disease’, Brit. Med. J., 302, 378–383.
Tobin, J.O’H., Dunnill, M.S., French, M. et al.(1980). ‘Legionnaires’ disease in a transplant unit: isolation of the causative agent from shower baths’, Lancet, ii, 118–121.
Tobin, J.O’H., Bartlett, C.L.R., Waitkins, S.A., et al., (1981). ‘Legionnaires’ disease: further evidence to implicate water storage and distribution systems as sources’, Brit. Med. J., 282, 573.
Glick, T.H., Gregg, M.B., Berman, B., et al., (1978). ‘Pontiac fever. An epidemic of unknown etiology in a health department: 1. Clinical and epidemiological aspects’. Am. J. Epidemiol., 107, 149–160.
Sarubbi, F.A., Kopf, H.B., Wilson, M.B., et al.(1982). ‘Increased recovery of Aspergillus flavus from respiratory specimens during hospital construction’, Am. Rev. Respir. Dis., 125(1), 33–38.
Kyriakides, G.K., Zinneman, H.H., Hallf, W.H., (1976). ‘Immunological monitoring and aspergillosis in renal transplant patients’. Am. J. Surg., 131, 246–252.
Solomon, W.R., (1970) ‘Fungus aerosols arising from cold mist vaporizers’, J. Allergy Clin. Immunol., 54,222–228.
Finnegan, M.J., Pickering, C.A.C., (1984). ‘Work related asthma and humidifier fever in airconditioned buildings’, in B. Berglund, T. Lindvall and J. Sundell (eds.), Proceedings of the 3rd International Conference on Indoor Air Quality and Climate, vol. 1: Recent Advances in Health Sciences and Technology. Swedish Council for Building Research, Stockholm, pp. 257–262.
Bürge, P.S., Finnegan, M.J., Horsfield, N., et al., (1985). ‘Occupational asthma in a factory with a contaminated humidifier’, Thorax, 40, 248–254.
Banaszak, E.F., Thiede, W.H., Fink, J.N., (1970). ‘Hypersensitivity pneumonitis due to contamination of an airconditioner’. N.Engl. J. Med., 283(6), 271–276.
Arnow, P.M., Fink, J.N., Schieuter, D.P. (1978). ‘Early detection of hypersensitivity in office workers’, Am. J. Med., 64, 236–241.
Sweet, L.C., Anderson, J.A., Cailles, Q.C., Coates, E.O., (1971). ‘Hypersensitivity pneumonitis related to a home furnace humidifier’, J, Allergy Clin. Immunol., 48, 171–179.
Fink, J.N., Banaszak, E.F., Thiede, W.H., Barboriak, J.J., (1971). ‘Interstitial pneumonitis due to hypersensitivity to an organism contaminating a heating system’, Ann. Int. Med.,74,80–83.
Tourville, D.R., Weiss, W.I., Wertlake, P.T., Loudemann, G.M., (1972). ‘Hypersensitivity pneumonitis due to contamination of home humidifier’, J. Allergy Clin. Immunol., 49, 245–251.
Hodges, G.R., Fink, J.N., Schlueter, D.P., (1974). ‘Hypersensitivity pneumonitis caused by a contaminated cool-mist vaporizer’, Ann. Int. Med., 80, 501–504.
Marinkovich, V.A., Hill, A., (1975). ‘Hypersensitivity alveolitis’, J.A.M.A., 231, 944–947.
Banaszak, E.F., Barboriak, J., Fink, J.N., et al., (1974). ‘Epidemiologic studies relating thermophilic fungi and hypersensitivity lung syndromes’, Am. Rev. Respir. Dis., 110, 585–591.
Robertson, A.S., Bürge, P.S., Weiland, A., (1985). ‘Extrinsic allergic alveolitis due to antigen from a humidifier at 15°C’, Thorax, 40(3), 229(abstr).
Metzger, W.J., Patterson, R., Fink, J., Semerdjian, R., Roberts, M., (1976). ‘Sauna-taker s Disease. Hypersensitivity pneumonitis due to contaminated water in a home sauna’, J.A.M.A., 236, 2209–2211.
Jacobs, R.L., Thorner, R.E., Holcomb, J.R. et al., (1986). ‘Hypersensitivity pneumonitis caused by Cladosporium in an enclosed hot-tub area’, Ann. Int. Med., 105, 204–206.
Fergusson, R.J., Milne, L.J.R., Crompton, G.K. (1984). ‘Penecillium allergic alveolitis: faulty installation of central heating’, Thorax, 39, 294–298.
Rose, C.S., Newman, L.S., Martyny, J.W. et al., (1991). ‘Outbreak of hypersensitivity pneumonitis in an indoor swimming pool: clinical, physiological, radiographic, pathologic, lavage and environmental findings’, Am. Rev. Respir. Dis., 143, A315.
Muittari, A., Kuusisto, P., Virtanen, P. et al., (1980). ‘An epidemic of extrinsic allergic alveolitis caused by tap water’, Clin. Allergy, 10, 77–90.
Friend, J.A.R., Gaddie, J., Palmer, K.N.V., Pickering, C.A.C., Pepys, J., (1977). ‘Extrinsic allergic alveolitis and contaminated cooling-water in a factory machine’, Lancet, i, 297–300.
Pestalozzi, C. (1959). ‘Febrile Gruppenerkrankungen in einer Modellschreinerei durch Inhalation von mit Schimmelpilzen Kontaminiertem Befeuchterwasser (‘Befeuchterfieber’)’, Schweiz. Med. Wochenschr., 89(27), 710–713.
‘Her Majesty’s Chief Inspector of Factories Annual Report for 1969’. H.M.S.O.: 1969:72–74.
Pickering, C.A.C., Moore, W.K.S., Lacy, J., et al., (1976). ‘Investigation of a respiratory disease associated with an airconditioning system’, Clin. Allergy, 6, 109–118.
Parrott, W.F., Blyth, W., (1980). ‘Another causal factor in the production of humidifier fever’, J. Soc. Occup. Med., 30, 63–68.
Rylander, R., Haglind, P., Lundholm, M., Mattsby, I., Stenqvist, K., (1978). ‘Humidifier fever and endotoxin exposure’, Clin. Allergy,8,511–516.
NewmanTaylor, A., Pickering, C.A.C., Turner-Warwick, M. (1978). ‘Respiratory allergy to a factory humidifier contaminant presenting as pyrexia of undetermined origin’, Brit. Med. J., 11,94–95.
Campbell, I.A., Cockcroft, A.E., Edwards, J.H., Jones, M., (1979). ‘Humidifier fever in an operating theatre’, Brit. Med. J., 2, 1036–1037.
Anderson, K., Watt, A.D., Sinclair, D. et al., (1989). ‘Climate, intermittent humidification, and humidifier fever’, Brit. J. Ind. Med., 46, 671–674.
Edwards, J.H., Griffiths, A.J., Mullins, J., (1976). ‘Protozoa as sources of antigen in humidifier fever’, Nature, 264, 438–439.
Finnegan, M.J., Pickering, C.A.C., Davies, P.S., Austwick, P.K.S., Warhurst, D.C., (1987). ‘Amoebae and humidifier’. Clin. Allergy, 17, 235–242.
Finnegan, M.J., Pickering, C.A.C, Davies, P.S., Austwick, P.K.C., (1985). ‘Factors affecting the development of precipitating antibodies in workers exposed to contaminated humidifiers’, Clin. Allergy, 15, 281–292.
Croft, W.A., Jarvis, B.B., Yatawara, C.S. (1986). ‘Airborne outbreak of trichothecene toxicosis’, Atmospheric Envir., 20, 549–552.
Nexo, E., Skov, P.G., Gravesen, S., (1983). ‘Extreme fatigue and malaise — a syndrome caused by badly cleaned wall--to-wall carpets?’ Ecology of Disease, 2, 415–418.
Harrison, J., Pickering, C.A.C, Faragher, E.B. et al. (in press). ‘An investigation of the relationship between microbial and particulate indoor air pollution and the sick building syndrome’, Respiratory Medicine.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1992 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
Pickering, C.A.C. (1992). The Effects of Microbiological Pollution in Buildings — Results of Building Investigations. In: Knöppel, H., Wolkoff, P. (eds) Chemical, Microbiological, Health and Comfort Aspects of Indoor Air Quality — State of the Art in SBS. Eurocourses: Chemical and Environmental Science, vol 4. Springer, Dordrecht. https://doi.org/10.1007/978-94-015-8088-5_18
Download citation
DOI: https://doi.org/10.1007/978-94-015-8088-5_18
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-4152-4
Online ISBN: 978-94-015-8088-5
eBook Packages: Springer Book Archive