Skip to main content

Electron beam computed tomography (EBCT)

  • Chapter
Book cover Advances in X-Ray Contrast

Abstract

The EBCT scanner is a special type of computed tomography (CT) unit (Figure 1). It was first introduced into clinical practice in 1983 [1], and, like a ‘conventional’ CT machine, creates transaxial slices of the human body or skull.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Boyd DP, Lipton MJ. Cardiac computed tomography. Proc IEEE. 1983; 71: 298–307.

    Article  Google Scholar 

  2. Stanford W, Galvin JR, Weis RM, et al. Ultrafast computed tomography in cardiac imaging. Semin Ultrasound CT MR. 1991; 12:45–60.

    PubMed  CAS  Google Scholar 

  3. McCollough CH, Morin RL. The technical design and performance of ultrafast computed tomography. Radiol Clin North Am. 1994; 32: 521–536.

    PubMed  CAS  Google Scholar 

References

  1. Stanford W, Rooholamini SA, Galvin JR. Ultrafast computed tomography in the diagnosis of aortic aneurysms and dissections. J Thorac Imaging. 1990; 5: 32–39.

    Article  PubMed  CAS  Google Scholar 

  2. Thompson BH, Stanford W. Utility of ultrafast computed tomography in the detection of thoracic aortic aneurysms and dissections. Semin Ultrasound CT MRI. 1993; 2: 117–128.

    Article  Google Scholar 

References

  1. Stanford W, Rooholamini SA, Galvin JR. Ultrafast computed tomography in the diagnosis of aortic aneurysms and dissections. J Thorac Imaging. 1990; 5: 32–39.

    Article  PubMed  CAS  Google Scholar 

  2. Hamada S. Type A aortic dissection: evaluation with ultrafast CT. Radiology. 1992; 183: 155–158.

    PubMed  CAS  Google Scholar 

  3. Thompson BH, Stanford W. Utility of ultrafast computed tomography in the detection of thoracic aortic aneurysms and dissections. Semin Ultrasound CT MRI. 1993; 2: 117–128.

    Article  Google Scholar 

References

  1. Rumberger JA, Sheedy PF, Stanson WA. Ultrafast (Cine) CT: Advantages and limitations in cardiovascular assessment. Internal Medicine. 1988; 6: 2–7.

    Google Scholar 

  2. Rumberger JA, Lipton MJ. Ultrafast cardiac CT scanning. Cardiol Clin. 1989; 8: 713–734.

    Google Scholar 

  3. Hamada S, Takamiya M, Ohe T. Arrythmogenic right ventricular dysplasia: Evaluation with electron-beam CT. Radiology. 1993; 6: 723–727.

    Google Scholar 

  4. Marcus LM, Rumberger JA, Stark CA, et al. Cardiac applications of ultrafast computed tomography. Am J Cardiac Imaging. 1988; 6: 116–121.

    Google Scholar 

  5. Naito H, Saito H, Takamiya M, et al. Quantitative assessment of myocardial enhancement with iodinated contrast medium in patients with ischemic heart disease by ultrafast X-ray computed tomography. Invest Radiol. 1992; 6: 436–441.

    Article  Google Scholar 

  6. Ludman PF, Coats AJ, Burger P, et al. Validation of measurement of regional myocardial perfusion in humans by ultrafast X-ray computed tomography. Am J Cardiac Imaging. 1993; 12: 267–279.

    Google Scholar 

  7. Marcus ML, Stanford W, Hajduczok ZD, et al. Ultrafast computed tomography in the diagnosis of cardiac disease. Am J Cardiol. 1989; 9: 54E–59E.

    Article  Google Scholar 

References

  1. Teigen CL, Maus TP, Sheedy PF, et al. Pulmonary embolism: diagnosis with contrast-enhanced electron-beam CT and comparison with pulmonary angiography. Radiology. 1995; 194: 313–319.

    PubMed  CAS  Google Scholar 

  2. Stein PD, Athanasoulis C, Alavi A, et al. Complications and validity of pulmonary angiography in acute pulmonary embolism. Circulation. 1992; 85: 462–468.

    Article  PubMed  CAS  Google Scholar 

  3. Remy-Jardin M, Remy J, Wattine L, et al. Central pulmonary thromboembolism: diagnosis with spiral volumetric CT with the single-breath-hold technique — comparison with pulmonary angiography. Radiology. 1992; 185: 381–387.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Knapp, R., Bangerl, I., zur Nedden, D. (1998). Electron beam computed tomography (EBCT). In: Dawson, P., Clauss, W. (eds) Advances in X-Ray Contrast. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-3959-5_10

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-3959-5_10

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-0-7923-8741-1

  • Online ISBN: 978-94-011-3959-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics