Skip to main content

Hydroxyapatite Coated Plate in the Surgical Treatment of the Forearm Non Union with Bone Loss

  • Chapter
Bioceramics and the Human Body

Abstract

From 1974 to 1990 23 forearm nonunions with bone loss were operated on at the third Department of Rizzoli Orthopaedic Institute. Length of bone loss ranged from 0.5 to 8 centimeters. The forearm nonunions were operated on of internal fixation with metallic plate; in 8 patients hydroxyapatite (HA) coated plates were implanted. A cortical-cancellous bone graft was interposed between the nonunion segments. A cortical bone graft was implanted opposite to the plate. Union was achieved in 21 cases. Functional results were evaluated according to the prono-supination range of motion. We had 10 excellent results, 5 good, 6 fair and 2 poor. The restoration of the shape and length of the forearm long bones is considered indispensable to obtain good functional results. The HA coated plate advantages could be osteoconductive property, bone direct apposition and bonding, no fibrous tissue formation near the plate, not necessary removal.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 74.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Zinghi, G. F., Montanari, G., and Specchia, L., La pseudartrosi diafisaria d’avambraccio. It. J. Orthop. Traum., 1981, 7, 205–219.

    Google Scholar 

  2. Ruggieri, F., Zinghi, G. F., and Lanfranchi, R., Le pseudoartrosi diafisarie. Aulo Gaggi, Bologna, 1977.

    Google Scholar 

  3. Nicoll, E.A., The treatment of gaps in long bones by cancellous insert graft. J. Bone Joint Surg., 1956, 38 B, 70–79.

    Google Scholar 

  4. Green, S.A., and Dlabal, T.A., The open graft for septic nonunion. Clin. Orthop., 1983, 117, 124–133.

    Google Scholar 

  5. De Buren, N., Causes and treatment of nonunion in fractures of the radius and ulna. J. Bone Joint Surg. 1962, 44 B, 614–622.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1992 Elsevier Science Publishers Ltd

About this chapter

Cite this chapter

Zinghi, G.F. et al. (1992). Hydroxyapatite Coated Plate in the Surgical Treatment of the Forearm Non Union with Bone Loss. In: Ravaglioli, A., Krajewski, A. (eds) Bioceramics and the Human Body. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-2896-4_9

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-2896-4_9

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-1-85166-748-2

  • Online ISBN: 978-94-011-2896-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics