Abstract
The bonding strength of uncoated, glass-coated and hydroxyapatite-coated cylindrical alumina implants was tested after implantation in the femora of Göttingen minipigs. HA-coating resulted in detachment of the coating during push-out test already 4 weeks after implantation at app. 4 MPa. A comparable bonding strength was reached in uncoated implants after 8 weeks and never was reached by only glass-coated implants.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Blencke, B.A., Brömer, H. und Deutscher, K.K., Experimentelle Untersuchungen über die Verankerung von belasteten glaskeramischen Implantaten im Femurschaft, Biomed Techn, 1979, 24, 294–302.
Bolz, U., Hüttemann, R.W., Kirschner, G. and Sturm, J., Indication for the clinical use of combined auto-alloplastic tooth reimplantation with aluminiumoxide ceramic, Dental implants, ed G. Heimke, C. Hanser Verlag, München, Wien, 1980, pp 81-87.
Boutin, P., Arthroplastie de la hanche par prothèse en alumine frittée, Rev. Chir. Orthop., 1971, 58, 229–246.
Dawihl, W., Mittelmeier, M., Dörre, E., Altmeyer, G. and Hanser, U., Zur Tribologie von Hüftgelenksprothesen aus Al2 O3-Keramik, Med Orthop Techn, 1979, 99, 114–118.
Dörre, E., Aluminiumoxidkeramik als Implantatwerkstoff, Med Orthop Techn, 1976, 4, 104–105.
Ehrl, P.A. and Frenkel G., Experimental and clinical experiences with blade-vent abutment of Al2 O3-ceramic in the shortened dental row situation of the mandible, Dental implants, ed. G. Heimke, C. Hanser Verlag, München, Wien, 1980, pp 63-67.
Griss, P., Silber, R., Merkle, B., Haener, K., Heimke, G. and Krempien, B., Biomechanically induced tissue reactions after Al2O3-ceramic hip joint replacement. Experimental and early clinical results, J Biomed Mater Res 1976, 7, 519–528.
Heimke, G., Beisler, W., von Andrian-Werburg, H., Griss, P. and Krempien, B., Untersuchungen an Implantaten aus Al2O3-Keramik, Ber Dt Keram Ges Nr.1, 1973, pp 5–8.
Hench, L.L., Splinter, R.J.M., Allen, W.C. and Greenlee, T.K., Bonding mechanisms at the interface of ceramic prosthetic materials, J Biomed Mater Res., 1971, 2, 117–141.
de Lange, G.L., de Putter, C., de Vos, R. and de Laat, R. Perumucosal dental implants, The relationship between bone anchorage and the quality of surrounding gingival tissues, Biological and Biomechanical Performance of Biomaterials, ed. P.Christel, A. Meunier and A.J.C. Lee, Elsevier, Amsterdam, N.Y. Tokyo, 1986, pp 519–524.
Strunz, V., Bunte, M., Stellmach, R., Gross, U.M., Kühl, K., Brömer, H. and Deutscher, K., Bioaktive Glaskeramik als Implantatmaterial in der Kieferchirurgie, Dtsch zahnärztl Z, 1977, 32, 287–290.
Ungethüm, M. and Fink, U., Bioaktive Werkstoffe. Eine kritische Übersicht, Z Orthop, 1988, 126, 697–708.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1992 Elsevier Science Publishers Ltd
About this chapter
Cite this chapter
Orth, J., Macedo, S., Wilke, A., Griss, P. (1992). Osseointegration of Hydroxyapatite-Coated and Uncoated Bulk Alumina Implants in the Femur of Göttingen Minipigs Mechanical Testing of Bonding Strength. In: Ravaglioli, A., Krajewski, A. (eds) Bioceramics and the Human Body. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-2896-4_41
Download citation
DOI: https://doi.org/10.1007/978-94-011-2896-4_41
Publisher Name: Springer, Dordrecht
Print ISBN: 978-1-85166-748-2
Online ISBN: 978-94-011-2896-4
eBook Packages: Springer Book Archive