Skip to main content

Flow Analysis Method for Trace Elements by Ion-Exchanger Phase Absorptiometry

  • Conference paper
Ion Exchange Advances

Abstract

The increase in attenuance of a colored species, which has been concentrated on-line onto ion exchanger packed in a flow-through cell, could be measured continuously with a spectrophotometer. The sensitivity of the present method depends both on the sample volume introduced into the flow system and the cross sectional area of the flow-through cell. It was possible to determine sample element concentration in mg/m3 or lower levels with a few cm3 of sample solution. The fundamental background and applicability to flow analysis of some trace elements are reviewed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 54.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Yoshimura, K., Waki, H. and Ohashi, S., Talanta, 1976, 23, 449–54.

    Article  CAS  Google Scholar 

  2. Waki, H. and Korkisch, J., Talanta, 1983, 30, 95–100.

    Article  CAS  Google Scholar 

  3. Capitan, F., Valencia, M.C. and Capitan-Vallvey, L.F., Mikrochim. Acta, 1984, 3, 303–11.

    Article  CAS  Google Scholar 

  4. Shriadah M.M.A. and Ohzeki, K., Analyst, 1985, 110, 677–79.

    Article  CAS  Google Scholar 

  5. Yoshimura, K. and Waki, H., Talanta, 1985, 32, 345–52.

    Article  CAS  Google Scholar 

  6. Nakashima, T., Yoshimura, K. and Waki, H., Talanta, 1990, 37, 735–39.

    Article  CAS  Google Scholar 

  7. Yoshimura, K. and Waki, H., Talanta, 1987, 34, 239–42.

    Article  CAS  Google Scholar 

  8. Yoshimura, K., Anal. Chem., 1987, 59, 2922–4.

    Article  CAS  Google Scholar 

  9. Yoshimura, K., Bunseki Kagaku, 1987, 36, 656–61.

    CAS  Google Scholar 

  10. Yoshimura, K., Analyst, 1988, 113, 471–74.

    Article  CAS  Google Scholar 

  11. Yoshimura, K., Matsuoka, S. and Waki, H., Anal. Chim. Acta, 1989, 225, 313–21.

    Article  CAS  Google Scholar 

  12. Yoshimura, K., Nawata, S. and Kura, G., Analyst, 1990, 115, 843–8.

    Article  CAS  Google Scholar 

  13. Matsuoka, S., Yoshimura, K. and Waki, H., Mem. Fac. Sci., Kyushu Univ., 1991, Ser. C, 18, 55–62.

    CAS  Google Scholar 

  14. Yoshimura, K. and Hase, U., Analyst, 1991, 116, 835–840.

    Article  CAS  Google Scholar 

  15. Yoshimura, K. and Matsuoka, S., New Developments in Ion Exchange, Kodansha, Tokyo, 1991, pp. 377–82.

    Google Scholar 

  16. Hase, U. and Yoshimura, K., Analyst, submitted.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1992 United Kingdom Atomic Energy Authority

About this paper

Cite this paper

Yoshimura, K., Matsuoka, S. (1992). Flow Analysis Method for Trace Elements by Ion-Exchanger Phase Absorptiometry. In: Slater, M.J. (eds) Ion Exchange Advances. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-2864-3_24

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-2864-3_24

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-1-85166-882-3

  • Online ISBN: 978-94-011-2864-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics