Skip to main content

Three Dimensional Reconstruction of Video-Recorded Ultrasound Images: Up-dates

  • Chapter
  • 77 Accesses

Part of the book series: Documenta Ophthalmologica Proceedings Series ((DOPS,volume 58))

Abstract

We present a new technique for the three-dimensional reconstructionof ultrasound images, describing the image acquisition process and the software used. We discuss the useful applications of such technique for discriminating between normal and pathological anatomical structures, as well as for an accurate volumetric measurement of intra-ocular lesions.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. E. Motolese, G. Addabbo, B. Daniello, N. Panterra, and M. Di Luzio. Ricostrizione tridimensionale in ecoftalmologia. Boll. Ocul. 1991, 70, N. 5, 1023–1032.

    Google Scholar 

  2. L. Falco, C. Mazzini, and F. Passani. The Ophthascan B (Biophysic Medical) a new A-and B-scan unit. Docum. Ophthal. Proc. Series 51. Ultrasonography in Ophthalmology, 11 (J.M. Thijssen, J.S. Hillman and P.E. Gallenga, Eds.) Kluwer Academic Publishers, Dordrecht 1988, 25–30.

    Google Scholar 

  3. L. Falco, S. Esente, N. Passarelli, and A. La Torre. RGB output: our experience. Docum. Ophthal. Proc. Series 53. Ultrasonography in Ophthalmology, 12 (R. Sampaolesi, Ed.) 1990, 487–489.

    Google Scholar 

  4. L. Falco, S. Esente, N. Passarelli, S. Utari, and V. Mazzeo. Differential diagnosis of vitreo-retinal membrane and in vivo thickness of detached retina using ultrasonic processing. 3rd International Congress on vitreo-retinal surgery. Rome, 1991, Proceedings in press.

    Google Scholar 

  5. D.J. Coleman, F.L. Lizzi, and R.L. Jack. Ultrasonography of the eye and orbit. Lea and Febiger, 1977, Philadelphia, 78–79.

    Google Scholar 

  6. R. Guthoff, D. Von Domarus, J. Draeger, and A. Bien. Tumor volume calculation by ultrasonographical data in the evaluation of regression patterns in ruthenium-treated melanomas. Doc. Ophthalmol. Proceeding series 53. (R. Sampaolesi, Ed.), Ultrasonography in Ophthalmology. Kluwer Academic Publishers, Dordrecht, 1990, 3–14.

    Google Scholar 

  7. Y. Yamamoto, Y. Sugata, M. Tomita, and M. Ito. Three dimensional display of the ocular region. Improvement of the scanning method. Doc. Ophthalmol. Proceedings Series 48. (K. C. Ossoinig Ed.), Ophthalmic Echography. Martinus Nijhoff/Dr W. Junk Publishers, Dordrecht, 1987, 207–214.

    Chapter  Google Scholar 

  8. Y. Yamamoto, M. Kubota, Y. Sugata, S. Matsui, and M. Ito. Three dimensional ultrasonography of ocular region. . Ophthalmol. Proceedings Series 51. (J. M. Thijssen, S. Hillman, P.E. Gallenga, Ed.) Kluwer Academic Publishers, Dordrecht 1988, 11–18.

    Google Scholar 

  9. Y. Sugata, Y. Yamamoto, and M. Ito. Three dimensional display of ocular region using an array transducer. Doc. Ophthalmol. Proceedings Series 53. (R. Sampaolesi, Ed.) Ultrasonography in Ophthalmology. Kluwer Ac. Publishers, Dordrect, pp. 461–466, 1990.

    Chapter  Google Scholar 

  10. D.J. Coleman, R.H. Silverman, M.J. Rondeau, and F.L. Lizzi. 3D Volume Rendering of Ocular Tumors. 6th World Congress in Ultrasound. Copenhagen, Sept. 1991. Proceedings in press.

    Google Scholar 

  11. D. Freedman and P. Diaconics. On the histogram as a density estimator: L2 Theory. Z. Wahrscheinlichkeitstheorie verw. Gebiete, Vol. 57, pp. 453–476, 1981.

    Article  Google Scholar 

  12. L. Falco, G. Paladini, S. Utari, S. Esente, and N. Passarelli. Ricostruzione tridimensionale computerizzata (VXL3D) di immagini ecografiche registrate su cassetta (VHS). Proceedings VI S.I.E.O. Congress, Clin. Ocul. n.4, 216–219, 1992.

    Google Scholar 

  13. S. Esente, L. Falco, and G. Paladini. Le reconstruction en trois dimensions par ordinateur des images echographiques enregistrees sur cassette VHS. LXXXXVIII Congress Societé Francais D’Ophtalmologie. Paris 1992. (Proceeding in press).

    Google Scholar 

  14. L. Falco, G. Paladini, S. Esente, and S. Utari. 3D reconstruction of intraocular tumors ultrasound images recorded on cassette: our experience. International Symposium on Ocular Tumors. New York 1992. (Oral presentation).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Falco, L., Paladini, G., Esente, S., Passarelli, N., Utari, S. (1995). Three Dimensional Reconstruction of Video-Recorded Ultrasound Images: Up-dates. In: Tane, S., Thijssen, J.M., Fledelius, H.C. (eds) Ultrasonography in Ophthalmology 14. Documenta Ophthalmologica Proceedings Series, vol 58. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-0025-0_4

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-0025-0_4

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-4015-0

  • Online ISBN: 978-94-011-0025-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics