Abstract
The desirability of initiating contraception soon after delivery is self-evident (Echeverry 1973; Zatuchni 1970: virtually no puerpera desires a new pregnancy right away and, except in women who are breast-feeding or taking a long-acting steroid preparation to inhibit lactation (van Bogaert et al. 1977), resumption of ovulation may take place early (Zarate et al. 1974).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Apelo R, Ramos R, Thomas M: The LEM device in an immediate postpartum contraceptive program. Fertil Steril 27: 517, 1976.
Banharnsupawat L, Rosenfield AG: Immediate postpartum IUD insertion. Obstet Gynecol 38: 276, 1971.
Bogaert LJ van, de Ridder Y, van der Pas H: First postpartum ovulation in women treated with a combination of ablactating steroids. Contraception 15: 319, 1977.
Castadot RG, Sivin I, Reyes P, Alers JO, Chappie M, Russell J: The International Postpartum Family Planning Program: eight years of experience, Reports on population and family planning 18, New York, Population Council, 1975.
Echeverry G: Family planning in the immediate postpartum period. Stud Fam Plan 4: (2): 33, 1973.
Goh TH: The use of a Karman cannula and suction to manage a retained IUD with retracted thread. Int J Gynaecol Obstet 16: 80, 1978.
Husemeyer RP, Gordon H: Retrieval of contraceptive device threads from within the uterine cavity. Lancet 1: 807, 1979.
Karim M, Ammar R, El Mahgaub S, El Granzoury B, Fikri F, Abdon I: Injected progestogen and lactation. Br Med J 1: 200, 1971.
Lancet: Review: missing threads. Lancet 1: 811, 1979.
Laufe LE, Wheelers RG, Friel PG: Modification of IUDs for postpartum use. Am J Obstet Gynecol, 1979.
Millen A, Austin F, Bernstein GS: Analysis of 100 cases of missing IUD strings. Contraception 18: 485, 1978.
Ministry of Health: Confidential enquiries into maternal deaths in England and Wales, 1964-1966, Ministry of Health reports on public health and medical subjects 119, London, HMSO, 1969.
Newton J, Harper M, Chan KK: Immediate post-placental ration IUDs yields significantly higher expulsion rates, the method effective provided the expulsions, most of insertion of intrauterine contraceptive devices. Lancet 2: 272, 1977.
Nilsson S, Nygren KG: Transfer of contraceptive steroids to human milk. Res Reprod 11 (1): 1, 1979.
Os W van, Thiery M, van der Pas H, Rhemrev P, Kosasih F, van Kets H, Amy J-J: Experience with a combined Multiload Cu250 intrauterine contraceptive device. Proc Int Cong Asian Fed Obstet Gynaec 1: 217, 1976.
Pollock M: The time of insertion of IUDs: a discussion. Br J Fam Plan 5 (1): 11, 1979.
Potts M: Postpartum IUD: the suture loop. IPPF Med Bull 12 (6): 4, 1978.
Prystowsky K, Eastman NJ: Puerperal tubal sterilization: report of 1830 cases. JAMA 158: 463, 1955.
Rashbaum WK, Wallach RC: Immediate postpartum insertion of a new intrauterine contraceptive device. Am J Obstet Gynecol 109: 1003, 1971.
Ruiz-Velasco V, Vargas MM, Goldsmith A: Aplicación del MLCu250 postalumbriamiento: reporte preliminar. Presented at the Mexican conference of obstetrics and gynecology, 1978.
Snowdon R, Williams M, Hawkins D: The IUD: a practical guide. London, Croom Helm, 1977.
Staelens R, Thiery m, Cliquet R: Psychologic-sexual assessment of sterilization [in Dutch]. T Geneesk, 1979.
Tatum HJ: Metallic copper as an intrauterine contraceptive agent. Am J Obstet Gynecol 117: 602, 1973.
Thiery M, van der Pas H, van Os WAA, Tauber PF, Dombrowic N, MacDonald JS, Haspels AA, Drogendijk AC, van Kets H, Boogers W: Three years experience with the MLCu250, a new copper-wired intrauterine contraceptive device. Adv Planned Parenthood 13: 35, 1978a.
Thiery M, van der Pas H, van Os WAA, van Kets H: Clinical experience with two never copper-loaded IUDs (TCu220C) and MLCu250): simultaneous use of an IUD and a spermi-cide; postplacental insertion of the MLCu250. In: Human Fertilization, Ludwig H, Taube PF (eds), Stuttgart, Thieme, 1978b, p 253ff.
Thiery M, van der Pas H, Delbeke L, van Kets H: Immediate post-placental insertion of the MLCu250. Br J Obstet Gynaecol, 1979a.
Thiery M, van der Pas H, Delbeke L, van Kets H: Randomized comparative trial of immediate postplacental insertion of MLCu250 and TCu200. Int J Obstet Gynaecol, 1979b (submitted).
Tow SH, Goon SM, Lean TH: Translocation of an intrauterine device: an analysis of 125 cases. Presented at the Second International Postpartum Family Planning Program Meeting, New York, 1967.
Valle RF, Sciarra JJ, Freeman DW: Hysteroscopic removal of intrauterine devices with missing filaments. Obstet Gynecol 49: 55, 1977.
Zanartu J, Aguilera E, Munoz G, Peliowsky H: Effect of a long- acting contraceptive progestogen on lactation. Obstet Gynecol 47: 174, 1976.
Zarate A, Canales ES, Soria J, Leon CN, Garrido J, Fonseca E: Refractory post-partum ovarian response to gonadal stimulation in non-lactating women. Obstet Gynecol 44: 819, 1974.
Zatuchni Gl: Postpartum Family Planning: a report of the international program, New York, McGraw-Hill, 1970.
Zerzavy FM: Use of intrauterine contraceptive devices in the postpartum period. Am J Public Health 57: 28, 1967.
Zipper J, Medel M, Goldsmith A, Edelman DA: Six-year continuation rates for Cu-T200 users. J Reprod Med 18: 95, 1977.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1980 Martinus Nijhoff Publishers bv, The Hague
About this chapter
Cite this chapter
Thiery, M. (1980). Immediate Postplacental Insertion of an IUD. In: Hafez, E.S.E., Van Os, W.A.A. (eds) Medicated Intrauterine Devices. Developments in Obstetrics and Gynecology, vol 5. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-8872-9_12
Download citation
DOI: https://doi.org/10.1007/978-94-009-8872-9_12
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-8874-3
Online ISBN: 978-94-009-8872-9
eBook Packages: Springer Book Archive