Abstract
Equipment parameters may limit the range of useful application of ultrasonic apparatus and transducer probes in ophthalmic ultrasonography. The reliability of ultrasonic diagnosis depends on close-to-optimum parameters and their maintenance. Therefore, the International Electrotechnical Commission, as well as AIUM and other national groups, have developed drafts on measurement of these parameters.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Baum, G. Fundamentals of Medical Ultrasonography. New York: Putnam’s Sons (1975).
Buschmann, W. Einführung in die ophthalmologische Ultraschalldiagnostik. Leipzig: Georg Thieme (1966).
Buschmann, W., Linnert, D. & Eysholdt, E. Measurement of equipment sensitivity in diagnostic ultrasonography, In: Ultrasound in medicine, Vol. 3B (D. White & R. Brown, eds.) New York: Plenum Publishing Corp. (1977) p. 1925.
Buschmann, W. Tumours of the eye and orbit. In: Ultrasound in Tumour Diagnosis (C.R. Hill, V.R. McCready & D.O. Cosgrove, eds.) Tunbridge Wells: Pitman Medical (1978).
Coleman, J.D., Lizzi, F.L. & Jack, R.L. Ultrasonography of the eye and orbit. Philadelphia: Lea & Febiger (1977).
Haigis, W. & Buschmann, W. Verhandlungsbericht SIDUO VII (H. Gernet, ed.) Münster: R.A. Remy-Verlag (1979) p. 59.
Haigis, W. & Buschmann, W. Die Benutzung von Testreflektoren zur schnellen klinischen Überprüfung von Geräten für die ophthalmologische Ultraschalldiagnostik. Proceedings, Gesellschaft für Biomedizin. Technik Berlin: (Sept. 1980).
Herrmann, G. & Buschmann, W. Kontrolle der Gesamtempfindlichkeit von Ultraschalldiagnostikgeräten und Schallköpfen über lange Zeiträume. v. Graefes Archiv Ophthalmol. 175: 223 (1968).
International Electrotechnical Commission, Technical Comm. 29 Electroacoustics, Subcommittee 29D: Ultrasonics, WG 4: Draft — Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment (1979).
Lepper, R.D., Trier, H.G. & Reuter, R. Beispiele für die Anwendung des Testprogramms mit Echosimulator an Geräten der Serie 7200 MA Kretztechnik, In: Diagnostica Ultrasonica in Opthalmologia (H. Gernet, ed.) Münster: Remy Verlag (1979) p. 48.
Lizzi, F.L. & Feleppa, E.J. Practical physics and electronics of ultrasound, In: Ophthalmic ultrasonography: Comparative Techniques. Int. Ophthalmol. Clinics 19 (R.L. Dallow, ed.) (1979).
Reuter, R. Der Zusammenhang klinisch relevanter Gerätefunktionen im A- und B-Bild und ihre Überprüfung durch ein differenzierungsfähiges Testprogramm. In: Diagnostica Ultrasonica in Ophthalmologia (H. Gernet, ed.) Münster: Remy-Verlag (1979) p. 44.
Till, P. & Ossoinig, K.C. First experiences with a solid tissue model for the standardization of A- and B-scan instruments in tissue diagnosis. In: Ultrasound in medicine, Vol. 3B (D. White & R.E. Brown, eds.) New York: Plenum Publishing Corp. (1977). p. 2167.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1981 Dr W. Junk Publishers, The Hague
About this paper
Cite this paper
Buschmann, W., Haigis, W. (1981). Influence of Equipment Parameters on Results in Ophthalmic Ultrasonography. In: Thijssen, J.M., Verbeek, A.M. (eds) Ultrasonography in Ophthalmology. Documenta Ophthalmologica Proceedings Series, vol 29. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-8659-6_73
Download citation
DOI: https://doi.org/10.1007/978-94-009-8659-6_73
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-8661-9
Online ISBN: 978-94-009-8659-6
eBook Packages: Springer Book Archive