Conditioned by the historical development, today’s ophthalmological diagnostic ultrasonic instruments differ considerably in their properties. Buschmann (this book) deals in more detail with this subject. Within the scope of standardization, quality control, and further development, enlarged ‘diagnostics’ of diagnostic equipment are nowadays required. Haigis & Till (this book) report about comparative measurements by means of test reflectors. I want to demonstrate in addition some measurement results gained with the ECHO-SIMULATOR, which we reported about during SIDUO VII.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Carson, P.L. Rapid evaluation of many pulse echo system characteristics by use of a triggered pulse burst generator with exponential decay. J. Clin. Ultrasound 4: 259 (1976).
Coleman, D.J. & Lizzi, F.L. In vivo choroidal thickness measurement. Am. J. Ophthalmol. 88: 369 (1979).
International Electrotechnical Commission, Technical Committee No. 29 Electroacoustics, Sub-Committee 29 D: Ultrasonics. Draft: Methods of measuring the performance of ultrasonic pulse echo diagnostic equipment. 29 D (secretariat) June 13,1978, Suppl. May 1979.
Lepper, R.-D. Ultraschallmessungen der Rückwand des lebenden menschlichen Auges Diss. Bonn (1978).
Lepper, R.-D. Trier, H.G. & Reuter R. Beispiele für die Anwendung des Testprogramms mit Echosimulator an Geräten der Serie 7200 MA Kretztechnik In: Ophthalmologia Diagnostica Ultrasonica (H. Gernet, ed.), Münster: Remy Verl. (1979).
Reuter, R. Der Zusammenhang klinisch relevanter Gerätefunktionen im A- und B-Bild un 1ihre Überprüfung durch ein differenzierungsfähiges Testprogramm In: Ophthalmologia Diagnostica Ultrasonica (H. Gernet, ed.) Münster: Remy Verl. (1979).
Reuter, R. Klinisch einsetzbares Verfahren zur ergänzenden Prüfung von Ultraschall-Diagnostikgeräten Proc. Ultraschalldiagnostik in der Medizin; Dreiländertreffen Davos, Februar 1979, Stuttgart: Thieme-Verl. (1980).
Reuter, R., Trier, H.G. & Lepper, R.-D. Ein elektrisches Prüfverfahren und Prüfgerät für Ultraschalldiagnostik-Anlagen. Acta Medicotechnica 28, 58 (1980).
Reuter, R., Trier, H.G. & Lepper, R.-D. Der Echosimulator, ein Funktions generator zur Messung relevanter Eigenschaften von Ultraschalldiagnostik-Geräten Biomed. Techn. 25, 163 (1980).
Till, P. Solid tissue model for the standardization of the echo-ophthalmograph 7200 MA (Kretztechnik). Docum. Ophthalmol. 41, 205 (1976).
Trier, H.G. Lichtdurchlässige, feststoffähnlich bearbeitbare Kunststoffe mit Schallgeschwindigkeit unter 2000 m/s. Proc. I. Weltkongr. Ultraschalldiagnostik Med. and SIDUO III, Vol. 2, 199(1969).
Williams, C. & Holmes, J.H. Pulse generator for verification of ultrasound equipment performance. In: Diagnostic Ultrasound, Vol. 3: 308 (1974).
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1981 Dr W. Junk Publishers, The Hague
About this paper
Cite this paper
Reuter, R., Lepper, RD., Haigis, W. (1981). Comparative Measurements on Ultrasonic Pulse-Echo Equipment with the Echosimulator. In: Thijssen, J.M., Verbeek, A.M. (eds) Ultrasonography in Ophthalmology. Documenta Ophthalmologica Proceedings Series, vol 29. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-8659-6_71
Download citation
DOI: https://doi.org/10.1007/978-94-009-8659-6_71
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-8661-9
Online ISBN: 978-94-009-8659-6
eBook Packages: Springer Book Archive