Skip to main content

Results of a Fluctuation Analysis and Defect Volume Program for Automated Static Threshold Perimetry with the Scoperimeter

  • Chapter
Sixth International Visual Field Symposium

Part of the book series: Documenta Ophthalmologica Proceedings Series ((DOPS,volume 42))

Abstract

We developed a Defect Volume (DV) program with the Scoperimeter to accurately compute both fluctuation and defect volume, with the ultimate purpose to statistically evaluate progression of visual field defects. After testing glaucoma patients we were able to show that unbiased threshold selection for determining individual sensitivity is very important in computing a defect volume, that individual gradient adaptation does not seem necessary, and that use of individual versus mean fluctuation remains controversial. Normal areas in glaucomatous visual fields may not be the same as fully healthy visual fields.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bebié, H. and Fankhauser, F. Delta manual. Published by Interzeag. Schlieren, Switzerland (1981).

    Google Scholar 

  2. Bebié, H., Fankhauser, F. and Spahr, J. Static perimetry: accuracy and fluctuations. Acta Ophthalmologica; 54: 339– 348 (1976).

    Article  PubMed  Google Scholar 

  3. van den Berg, TJTP., van Veenendaal, W. and van Spronsen, R. Psychophysics of intensity discrimination in relation to defect volume examination on the Scoperi- meter. Docum Ophthal Proc Series This volume (1984).

    Google Scholar 

  4. Langerhorst, C.T., van den Berg, T.J.T.P., van Yeenendaal, W. and Greve, E.L. Schatting van de verschillende fluctuatiefactoren bij glaucoompatiënten. Ned. Tijdschr. v. Geneesk. 127 (53): 2443 (1983).

    Google Scholar 

  5. Langerhorst, C.T., van den Berg, T.J.T.P. and Greve, E.L. Schätzung der verschiedene Fluktuationsfaktoren bei der Computerperimetrie von Glaukompatienten. To be published in Bucherei der Augenarztes der Enkes-Verlag (1984).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

A. Heijl E. L. Greve

Rights and permissions

Reprints and permissions

Copyright information

© 1985 Dr. W. Junk Publishers, Dordrecht, The Netherlands

About this chapter

Cite this chapter

Langerhorst, C.T., Van Den Berg, T.J.T.P., Van Spronsen, R., Greve, E.L. (1985). Results of a Fluctuation Analysis and Defect Volume Program for Automated Static Threshold Perimetry with the Scoperimeter. In: Heijl, A., Greve, E.L. (eds) Sixth International Visual Field Symposium. Documenta Ophthalmologica Proceedings Series, vol 42. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-5512-7_1

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-5512-7_1

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-8932-6

  • Online ISBN: 978-94-009-5512-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics