Abstract
The performance of melt extract and wire fibre reinforced sprayed concretes produced at three field trials in the UK is reported. An emphasis was placed on measuring properties relevant to the applications of the material and in particular the effects of in situ fibre content and fibre type. Flexural strength was found to increase significantly with fibre content in a linear relationship from the unreinforced strength. Core compressive strengths of around 70 MN/m2 were achieved and increased slightly with in situ content. Toughness index, calculated from beam load/deflection curves, increased rapidly with fibre content to over 30 times that of the unreinforced matrix at 7% by weight. Two splitting tests on cores were investigated as possible methods of on site quality control and results indicated linear relationships between flexural and splitting strengths.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Anon. Hong Kong Bank hits appraisal impasse, NCE (June 9, 1983 ), 4–5.
Anon. Stainless Steel Reinforces Derby Sewers, NCE (June 23, 1983 ), 30–31.
Barfoot, J., Sprayed fibrous concrete tunnel support, Concrete, 17, No. 11 (Nov. 1983), 9–11.
Robins, P. J. and Austin, S. A., Sprayed steel fibre concrete: production and placing, Concrete, 19, No. 3 (March 1985).
Austin, S. A., Melt extract fibre reinforced composites, Ph.D. Thesis, Loughborough University of Technology, June, 1984.
Moens, J. and Nemegeer, D., Flexural strength of fibre reinforced test beams, Rilem Symp. Testing and Test Methods of Fibre Cement Composites, Construction Press, 1978, pp. 389–398.
Johnston, C. D., Steel fibre reinforced and plain concrete: factors influencing flexural strength measurement, ACI Journal, Proc., 79, No. 2 (March 1982), 131–138.
Ramakrishnan, V., Coyle, W. V., Fowler, L. J. and Schrader, E. K., A Comparative Evaluation of Fibre Shotcretes, South Dakota School of Mines and Technology, August, 1979.
Morgan, D. R., Steel fibre shotcrete—a laboratory study, Concrete International, 3, No. 1 (Jan. 1981), 70–74.
Johnston, C. D., Steel fibre reinforced mortar and concrete: a review of mechanical properties, ACI SP-44 (1973), 127–142.
Swamy, R. N. and Mangat, P. S., Flexural strength of steel fibre reinforced concrete, Proc. ICE, Part 2, 57 (1974), 701–707.
Edgington, J., Hannant, D. J. and Williams, R. I. T., Steel Fibre Reinforced Concrete, Building Research Establishment, CP 69 /74, July 1974.
Hannant, D. J., Fibre Cements and Fibre Concretes, New York, John Wiley, 1978.
ACI Committee 544, Measurement of properties of fiber reinforced concrete, ACI Journal, 75, No. 7 (July 1978), 283–289.
Robins, P. J., The point-load test for tensile strength estimation of plain and fibrous concretes, in situ/non-destructive testing of concrete, ACI, SP-82, October 1984, 309–325.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1985 Elsevier Applied Science Publishers Ltd
About this chapter
Cite this chapter
Robins, P.J., Austin, S.A. (1985). Melt Extract Fibre Reinforced Sprayed Concrete. In: Marshall, I.H. (eds) Composite Structures 3. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-4952-2_18
Download citation
DOI: https://doi.org/10.1007/978-94-009-4952-2_18
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-8695-0
Online ISBN: 978-94-009-4952-2
eBook Packages: Springer Book Archive