Summary

A description is given of the calibration procedure as derived and followed by TNO-IWECO when calibrating force transducers. From the measuring results some parameters are being derived by which the transducer is classified. The classification scheme is also presented. A short description is given of TNO-IWECO’s facilities for carrying out the calibrations. Attention is being given to the system which has been set up for securing the traceability of the used facilities. In this respect special reference is made to results of intercomparisons which have been carried out. In particular the results of an intercomparison between PTB and TNO in the case of three transfer standards are given. Two transfer standards which are of the build-up type are used for linking force generating machines to the 550 kN deadweight standardizing machine of TNO-IWECO. They can also be used for calibrating force transducers by positioning them upon the transfer standard in a force generating machine.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Material prufung 16 (1974), p 165-169

    Google Scholar 

  2. Ir. H. Wieringa, “Parallel schakelen van opnemers” april 1983, TNO-IWECO, rapport no 5221002-831 (Dutch)

    Google Scholar 

  3. Ir. H. Wieringa, “ontwikkeling 1,65MN en 4,95MN kalibratie standaards”, 1983, TNO-IWECO, rapport no. 5221002-83-2 (Dutch)

    Google Scholar 

  4. Ir. H. Wieringa, Deadweight standardizing machine 5500 kgf, VDI-Berichte nr. 137, 1970

    Google Scholar 

  5. Ir. H. Wieringa, Design of a 1,65 and 4,95 MN transfer standard, based on the “build-up” procedure, Proceedings 10th Int. Conf. of the IMEKO Techn. Comm. TC-3 on Measurement of Force and Mass, Kobe, Japan, Sept. 11-14, 1984, pp 205 - 208.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1986 Martinus Nijhoff Publishers, Dordrecht

About this chapter

Cite this chapter

Brandenburg, P.J., Appij, J.M., Loomans, J., Wieringa, H. (1986). Calibration and Classification of Force Transducers by Using a Traceable Set of High-Performance Facilities. In: Wieringa, H. (eds) Mechanical Problems in Measuring Force and Mass. ITC Series No. 8, vol 3. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-4414-5_25

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-4414-5_25

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-8464-2

  • Online ISBN: 978-94-009-4414-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics