Abstract
When Ludwig Rehn successfully repaired a right ventricular stab wound in 1896, he opened up a new page in the treatment of cardiac disease.[1] The decades that followed witnessed exponential progress in the surgical management of valvular, congenital and ischemic cardiac problems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Rehn L: Ãœber penetrierende herzwanden und herzhant. Arch Klin Chir 55: 315, 1897.
Hufnagel CA, Harvey WP. The surgical correction of aortic insufficiency. Bull Georgetown U Med Cent, 6: 60, 1953.
Lefrak EA, Starr A: Cardiac valve prostheses, New York, Appleton-Century-Crofts, 1979.
Starr A: Total mitral valve replacement: fixation and thrombosis. Surg Forum, 11: 258, 1960.
Starr A, Edwards ML: Mitral replacement: The shielded ball-valve prosthesis. J Thorac Cardiovasc Surg, 42: 673, 1961.
Starr A, Edwards ML: Mitral replacement: Clinical experience with a ball valve prosthesis. Ann Surg, 156: 726, 1961.
Starr A, Herr RH, Wood JA: Mitral replacement: Review of six years’ experience. J Thorac Cardiovasc Surg 54: 333, 1967.
Pierie WR, Hancock WD, Koorajian S, Starr A: Materials and heart valve prostheses. Ann NY Acad Sci, 146: 345, 1968.
Herr RH, Starr A, Pierie WR, Wood JA, Bigelow JC: Aortic valve replacement: A review of six years’ experience with ball-valve prosthesis. Ann Thorac Surg, 6: 199, 1968.
Starr A, Herr R, Wood JA: Accumulated experience with the Starr-Edwards prosthesis 1960–1968. In Brewer LA III (ed): Prosthetic Heart Valves. Springfield, Thomas, 1969, pp. 468–482.
Bonchek LI, Anderson RP, Starr A: Mitral valve replacement with cloth-covered composite-seat prostheses. J Thorac Cardiovasc Surg, 67: 93, 1974.
Starr A, Grunkemeier G, Lambert L, et al: Mitral valve replacement: A 10-year follow-up of non-cloth-covered vs. cloth-covered caged-ball prostheses. Circulation, 54 (Suppl. III): 47, 1976.
Bonchek LI, Starr A: Ball valve prostheses: current appraisal of late results. Am J Cardiol, 35: 843, 1975.
Dellsperger KC, Weiting DW, Baehr DA, et al: Regurgitation of prosthetic heart valves: Dependence on heart rate and cardiac output. Am J Cardiol, 51: 321, 1983.
Glancy DL, O’Brien KP, Reis RL, et al: Hemodynamic studies in patients with 2M and 3M Starr-Ed¬wards prostheses: Evidence of obstruction to left atrial emptying. Circulation, 39–40 (Suppl I): 113, 1969.
Macmanus Q, Grunkemeier GL, Lambert LE, Teply JF, Harlan BJ, Starr A: Year of operation as a risk factor in the late results of valve replacement. J Thorac Cardiovasc Surg, 80: 836, 1980.
Wain WH, Drury PJ, Ross DN: Aortic valve replacement with Starr-Edwards valves over 14 years. Ann Thor Surg, 33: 562, 1981.
Sala A, Schoevaerdts JC, Jaumin P, Ponlot R, Chalant CH: Review of 387 isolated mitral valve replacements by the Model 6120 Starr-Edwards prosthesis. J Thorac Cardiovasc Surg, 84: 744, 1982.
Björk VO, Henze A: Ten years’ experience with the Björk-Shiley tilting disc valve. J Thorac Cardiovasc Surg, 78: 331, 1979.
Moreno-Cabrel RJ, McNamara JJ, Mamiya RT, Brainard SC, Chung GKT: Acute thrombotic obstruction with Björk-Shiley valves. Diagnostic and surgical considerations. J Thorac Cardiovasc Surg, 75: 321, 1980.
Copans MB, Lakier JB, Kinsley RH, Colsen PR, Fritz VU, Barlow JB: Thrombosed Björk-Shiley mitral prosthesis. Circulation, 61: 169, 1980.
Ayuso LA, Juffe A, Rufilanchas JJ, Babin F, Burgos R, Figuera D: Thrombectomy: Surgical treatment of the thrombosed Björk-Shiley prosthesis. Report of seven cases and review of the literature. J Thorac Cardiovasc Surg, 84: 906, 1982.
Wright JO, Hiratzka LF, Brandt B, Doty DB: Thrombosis of the Bjork-Shiley prosthesis. Illustrative cases and review of the literature. J Thorac Cardiovasc Surg, 84: 138, 1982.
Yoganathan AP, Corcoran WH, Harrison EC, Carl JR: The Björk-Shiley aortic prosthesis: Flow characteristics, thrombus formation and tissue overgrowth. Circulation, 58: 70, 1978.
Karp RB, Cyrus RJ, Blackstone EH, Kirklin JW, Kouchoukos NT, Pacifico AD: The Björk-Shiley valve: intermediate-term follow-up. J Thorac Cardiovasc Surg, 81: 602, 1981.
Murphy DA, Levine FH, Buckley MJ, Swinski L, Daggett WM, Akins CW, Austen WG: Mechanical valves: a comparative analysis of the Starr-Edwards and Björk-Shiley prostheses. J Thorac Cardiovasc Surg, 86: 746, 1983.
Metzdorff MT, Grunkemeier GL, Pinson CW, Starr A: Thrombosis of mechanical cardiac valves: A qualitative comparison of the silastic ball valve and the tilting disc valve. J Amer Coll Cardiol, 1984, in. press.
Hetzer RO, Hill JD, Kerth WJ, Ansbro J, Adappa MG, Rodvien R, Kamm B, Gerbade F: Thromboembolic complications after mitral valve replacement with Hancock xenograft. J Thorac Cardiovasc Surg,. 75: 651, 1978.
Oyer PE, Stinson EB, Rossiter SJ, Miller DC, Reitz BA, Shumway NE: Extended experience with the Hancock xenograft bioprosthesis. Presented at the Symposium on Bioprosthetic Heart Valves, Munich Germany, April 5–7, 1979.
Oyer PE, Miller DC, Stinson EB, Reitz BA, Mareno-Cabral RJ, Shumway NE: Clinical durability of the Hancock porcine bioprosthetic valve. J Thorac Cardiovasc Surg, 80: 824, 1980.
Pelletier C, Chaitman BR, Baillot R, Vail PG, Bonan R, Dyrda I: Clinical and hemodynamic results with the Carpentier-Edwards porcine bioprosthesis. Ann Thorac Surg, 34: 612, 1982.
Janusz MT, Jamieson WRE, Allen P, Munro AI, Miyagishima RT, Tutassura H, Burr LH, Gerein AN,. Tyers GFO: Experience with the Carpentier-Edwards porcine valve prosthesis in 700 patients. Ann Thorac Surg, 34: 625, 1982.
Personal experience, 1983.
Miller DC, Oyer PE, Stinson EB, Reitz BA, Jamieson SW, Baumgartner WA, Mitchell RS, Shumway NE: Ten to fifteen year reassessment of the performance characteristics of the Starr-Edwards Model 6120 mitral valve prosthesis. J Thorca Cardiovasc Surg, 85: 1, 1983.
Becker RM, Sandor L, Tindel M, Frater RWM: Medium-term follow-up of the Ionescu-Shiley heterograft valve. Ann Thor Surg, 32: 120, 1981.
Cohn LH, Mudge GH, Pratter F, Collins JJ: Five to eight year follow-up of patients undergoing porcine heart valve replacement. New England J Med, 304: 258, 1981.
Gallo JI, Ruiz B, Carrion MF, Gutierrez JA, Vega JL, Duran CMG: Heart valve replacement with the Hancock bioprosthesis: A six-year review. Ann Thorac Surg, 31: 444, 1981.
Borkon AM, Mcintosh CL, Von Rueden JJ, Morrow AG: Mitral valve replacement with the Hancock, bioprothesis: Five to ten year follow-up. Ann Thorac Surg, 32: 127, 1981.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1986 Science Press, Beijing and Martinus Nijhoff Publishers, Dordrecht
About this chapter
Cite this chapter
Starr, A., Cobanoglu, A. (1986). Starr-Edwards Prostheses: Past to Present. In: Wu, Y., Peters, R.M. (eds) International Practice in Cardiothoracic Surgery. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-4259-2_80
Download citation
DOI: https://doi.org/10.1007/978-94-009-4259-2_80
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-8391-1
Online ISBN: 978-94-009-4259-2
eBook Packages: Springer Book Archive