Prevention of arrhythmic death with the automatic implantable cardioverter-defibrillator

  • Chapter
  • 49 Accesses

Part of the book series: Developments in Cardiovascular Medicine ((DICM,volume 71))

Abstract

Because the treatment of ventricular fibrillation and many hemodynamically unstable ventricular tachycardias with electrical countershock is critically dependent on rapid availability of medical personnel and equipment, its implementation outside the hospital is rarely successful. This situation has prompted the development of a fully implantable automatic device designed for continuous monitoring of the heart rhythm and prompt recognition and treatment of life-threatening ventricular tachyarrhythmias [1]. Since the first implantation of such a device in a human being at The Johns Hopkins Hospital [1], the automatic implantable cardioverter-defibrillator (AICD*) is being used with increased frequency to prevent sudden cardiac death in high-risk patients [2–8]. The growing clinical experience has demonstrated that this therapeutic intervention dramatically lowers the prohibitive arrhythmic mortality of this population [3, 8, 9].

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Mirowski M, Reid PR, Mower MM, Watkins L, Gott VL, Schauble JR, Langer A, Heilman MS, Kolenik SA, Fischell RE, Weisfeldt ML. 1980. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 303: 322–324.

    Article  PubMed  CAS  Google Scholar 

  2. Mirowski M, Reid PR, Watkins L, Weisfeldt ML, Mower MM. 1981. Clinical treatment of life-threatening ventricular tachyarrhythmias with the automatic implantable defibrillator. Amer Heart J 102: 265–270.

    Article  PubMed  CAS  Google Scholar 

  3. Mirowski M, Reid PR, Winkle RA, Mower MM, Watkins L, Stinson EB, Griffith LSC, Kallman CH, Weisfeldt ML. 1983. Mortality in patients with implanted automatic defibrillators. Ann Inter Med 98: 585–588.

    CAS  Google Scholar 

  4. Mirowski M, Reid PR, Mower MM, Watkins Jr L, Platia EV, Griffith LSC, Juanteguy JM. 1984. The automatic implantable cardioverter-defibrillator. PACE 7: 534–540.

    PubMed  CAS  Google Scholar 

  5. Reid PR, Mirowski M, Mower MM, Platia EV, Griffith LSC, Watkins Jr L. 1983. Clinical evaluation of the internal automatic cardioverter-defibrillator in survivors of sudden cardiac death. Amer J Cardiol 51: 1608–1613.

    Article  PubMed  CAS  Google Scholar 

  6. Reid PR, Mower MM, Mirowski M. 1984. Pathophysiology of ventricular tachyarrhythmias amenable to electric control. PACE 7: 505–513.

    PubMed  CAS  Google Scholar 

  7. Reid PR, Griffith LSC, Mower MM, Platia EV, Watkins Jr L, Juanteguy J, Mirowski M. 1984. Implantable cardioverter-defibrillator: Patient selection and implantation protocol. PACE 7: 1338–1344.

    PubMed  CAS  Google Scholar 

  8. Echt DS, Armstrong K, Schmidt P, Oyer PE, Stinson EB, Winkle RA. 1985. Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation 71 (No. II): 291–296.

    Article  Google Scholar 

  9. Reid PR, Mower MM, Griffith LSC, Platia EV, Watkins Jr L, Juanteguy J, Guarnieri T, Mirowski M. 1984. Comparative effects on mortality of the first and second generation implantable defibrillators (abstr). Circulation 70:11–401.

    Google Scholar 

  10. Watkins Jr L, Mirowski M, Mower MM, Reid PR, Griffith LSC, Vlay SC, Weisfeldt ML, Gott VL. 1981. Automatic defibrillation in man: The initial surgical experience. J Thorac Cardiovasc Surg 82: 492–500.

    PubMed  Google Scholar 

  11. Watkins Jr L, Mirowski M, Mower MM, Reid PR, Freund P, Thomas A, Weisfeldt ML, Gott VL.1982. Implantation of the automatic defibrillator: The subxiphoidal approach. Ann Thorac Surg 34: 515–520.

    Article  PubMed  Google Scholar 

  12. Lawrie GM, Griffin JC, Wyndham CRC. 1984. Epicardial implantation of the automatic implantable defibrillator by left subcostal thoracotomy. PACE 7: 1370–1374.

    PubMed  CAS  Google Scholar 

  13. Brodman R, Fisher JD, Furman S, Johnston DR, Kim SG, Matos JA, Waspe LE. 1984. Implantation of automatic cardioverter-defibrillators via median sternotomy. PACE 7: 1363–1369.

    PubMed  CAS  Google Scholar 

  14. Platia EV, Griffth LSC, Watkins Jr L, Mower MM, Guarnieri T, Mirowski M, Reid PR. 1986. Treatment of malignant ventricular arrhythmias with endocardial resection and implantation of the automatic cardioverter-defibrillator. N Engl J Med 314: 213–216.

    Article  PubMed  CAS  Google Scholar 

  15. Winkle RA, Bach SM, Echt DS, Swerdlow CD, Imran M, Mason JW, Oyer PE, Stinson EB. The automatic implantable defibrillator: Local ventricular bipolar sensing to detect ventricular tachycardia and fibrillation. Am J Cardiol 52: 265–270.

    Article  PubMed  CAS  Google Scholar 

  16. Winkle RA, Stinson EB, Bach Jr SM, Echt DS, Oyer PE, Armstrong K. 1984. Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration. Circulation 69: 766–771.

    Article  PubMed  CAS  Google Scholar 

  17. Winkle RA, Stinson EB, Echt DS, Mead RH, Schmidt P. 1984. Practical aspects of automatic cardioverter/defibrillator implantation. Am Heart J 108:1335–1346.

    Article  PubMed  CAS  Google Scholar 

  18. Mower M, Reid PR, Watkins Jr L, Mirowski M. 1983. Use of alternating current during diagnostic electrophysiologic studies. Circulation 67: 69–72.

    Article  PubMed  CAS  Google Scholar 

  19. Graboys TB, Lown B, Podrid PJ, DeSilva R. 1982. Long-term survival of patients with malignant ventricular arrhythmia treated with antiarrhythmic drugs. Am J Cardiol 50: 437–443.

    Article  PubMed  CAS  Google Scholar 

  20. Schulze RA Jr, Strauss HW, Pitt B. 1977. Sudden death in the year following myocardial infarction: Relation to ventricular premature contractions in the late hospital phase and left ventricular ejection fraction. Am J Med 62:192–199

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Martinus Nijhoff Publishers, Dordrecht

About this chapter

Cite this chapter

Mirowski, M., Mower, M.M., Veltri, E.P., Juanteguy, J.M. (1987). Prevention of arrhythmic death with the automatic implantable cardioverter-defibrillator. In: Aliot, E., Lazzara, R. (eds) Ventricular Tachycardias. Developments in Cardiovascular Medicine, vol 71. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-3323-1_28

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-3323-1_28

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-7992-1

  • Online ISBN: 978-94-009-3323-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics