Abstract
Monitoring fouling can provide useful information to permit the effective operation of heat exchangers. Different techniques are used to detect fouling by observing the buildup of a fouling layer, the accompanying deterioration in the thermal performance, and the increase in the overall pressure drop. Some monitors determine the relative performance of particular heat exchangers to signal the time for cleaning. Other monitors are used to evaluate the effectiveness of various treatment programs to control corrosion and minimize fouling. All have the objective of understanding more about the fouling characteristics of plant streams that are known to foul heat exchangers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Knudsen, J. G., “Apparatus and Techniques for Measuring of Fouling of Heat Transfer Surfaces,” Fouling of Heat Transfer Equipment, pp. 57–81, Hemisphere, Washington, 1981.
Fischer, P., Suitor, J. W., and Ritter, R. B., “Fouling Measurement Techniques,” Chem. Engr. Prog., Vol. 71, No. 7, pp. 66–72 (1975).
Fetkovich, J. G., Grannemann, G. N., Mahalingham, L. M., and Meier, D. L., “A System for Measuring the Effect of Fouling on Heat Transfer Under Simulated OTEC Conditions,” Proc. 4th Conf. on Ocean Thermal Energy Conversion, pp. VII-15–23, New Orleans, 1977.
Fetissoff, P. E., Watkinson, A. P. and Epstein, N., “Comparison of Two Heat Transfer Fouling Probes,” Proc. 7th Intl. Heat Trans. Conf., Vol. 6, pp. 391–396. Munich, 1982.
Fryer, P. J., Pritchard, A. M., Slater, N. K. H., and Laws, J. F., “A New Device for Studying the Effects of Surface Shear Stress on Fouling in the Presence of Heat Transfer,” ASME HTD-Vol. 35, pp.33–42, Nalt. Heat Transfer Conf., Niagara Fails (1984).
Wilson, E. E., “A Basis for Rational Design of Heat Transfer Apparatus,” Trans. ASME, Vol.37, pp. 47–82 (1915).
Bell, K. J. (ed.), “Thermal and Hydraulic Design of Heat Exchangers,” Heat Exchanger Design Handbook, Vol. 3, Hemisphere, Washington, 1983.
Crittenden, B. D. and Khather, E. M. H., “Fouling from Vaporizing Kerosene,” Fouling in Heat Exchange Equipment, J. W. Suitor and A. M. Pritchard, eds., ASME HTD-Vol. 35, pp. 57–64 (1984).
Moore, W. E. and Hays, G. F., “Guidelines for Selection and Use of On-Line Fouling Monitors,” Paper TP-85–2, Cooling Tower Institute, CTI Annual Meeting, 1985.
Lira, R., Poteat, L. E., Camerota, L, and Sengupta, S., “Marine Biofouling Control with Anodically Polarized Protection in Shell and Tube Heat Exchangers,” Effects of Fouling and Corrosion on Heat Transfer, ASME HTD-Vol. 50, pp. 25–32, Miami Beach (1985).
Sato, S., Nosetani, T., Hotta, Y., Ikushima, Y., and Yamashita, S., “Improvement of Surface Condenser Performance by In-Situ Artificial Protective Film Coating,” Effects of Fouling and Corrosion on Heat Transfer, ASME HTD-Vol. 50, pp. 17–24, Miami Beach (1985).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1988 Kluwer Academic Publishers
About this chapter
Cite this chapter
Chenoweth, J.M. (1988). Liquid Fouling Monitoring Equipment. In: Melo, L.F., Bott, T.R., Bernardo, C.A. (eds) Fouling Science and Technology. NATO ASI Series, vol 145. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-2813-8_4
Download citation
DOI: https://doi.org/10.1007/978-94-009-2813-8_4
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-7766-8
Online ISBN: 978-94-009-2813-8
eBook Packages: Springer Book Archive