Abstract
Large scale experiments performed on seismic shaking tables in the last 40 years have significantly influenced the development of earthquake engineering in general. They provide very useful information on materials, joints, elements and the overall structural behaviour when subjected to different earthquake motions in controllable laboratory conditions. Based on this information great improvement has been made in the modelling and physical understanding of the structural behaviour of different structural systems. These improvements, in turn, have enhanced the seismic design code practice. Based on a large number of performed tests, the purpose of experimentation could be classified in the following categories: testing of physical models for better understanding of the dynamic behaviour of structures, development of technologies in earthquake engineering, and proof and seismic qualification tests of vital mechanical and electrical equipment. In this paper a critical analysis of tests performed in Dynamic Testing Laboratory at Institute of Earthquake Engineering and Engineering Seismology–IZIIS, Skopje, R. Macedonia, is done from the point of view of the constraints present in using shaking tables for different testing categories.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bojadziev M, Tashkov Lj, Paskalov T (1993) Model testing of the seismic stability of the stone fill dam ‘Kozjak’ on Treska River. IZIIS report 93-027
Boschi E, Rovelli A, Funiciello R, Giufre A, Mihailov V, Tashkov Lj, Krstevska L, Mamucevski D, Stamatovska S (1995) Analysis of the seismic risk of existing column monuments in Rome by seismic shaking table testing of a model, vol 2. IZIIS report, Oct 1995
Bulletin of Earthquake Engineering (2008–2010) vols 6–8. Springer
Earthquake Engineering & Structural Dynamics (2008–2010) vols 37–39. Wiley
Earthquake Spectra (2008–2010) Volumes 24–26. EERI
Earthquake Shaking Table – A World List of Shaking Tables. Wikipedia http://en.wikipedia.org/wiki/Earthquake_shaking_table. Accessed 10 Jan 2011
Gavrilovic P, Gramatikov K, Tashkov Lj, Krstevska L, Mamucevski D (1990) Dynamic Analysis of Timber Truss Frame Systems Project JFP-760/40 AES-192 USDA. IZIIS Report 90-47
Gavrilovic P, Sendova V, Tashkov Lj, Krstevska L, Ginell W, Tolles L (1996) Shaking table tests of adobe structures. Report IZIIS 96-36
Gavrilovic P, Sendova V, Kelley S (2001) Earthquake protection of Byzantine churches using seismic isolation. Macedonian – US joint research. Report IZIIS 2001
Jurukovski D, Mamucevski D, Petkovski M (1987) Report on testing of the seismic resistance of the current transformer ISF 420/525 manufactured by Energoinvest – Sarajevo. IZIIS Report 87-22
Jurukovski D, Mamucevski D (1988) Report on testing of the seismic resistance of metal enclosed high voltage equipment type MOP-A3 manufactured by Energoinvest – Sarajevo. IZIIS report 88-109
Jurukovski D, Rakicevic Z (2004a) Shaking table testing of a frame model with GERB Base Control System (BCS). IZIIS report 2004-50
Jurukovski D, Rakicevic Z (2004b) Shaking table testing of a frame model with GERB Tuned Mass Control System (TMCS). IZIIS Report 2004-51
Jurukovski D, Rakicevic Z (2005) Proof tests on a shaking table of a ventilated facade system manufactured by SONICO, Italy. IZIIS report 2005-33
Jurukovski D, Mamucevski D, Tashkov Lj, Hadzi-Tosev N, Trajkovski V (1984a) Shaking table test of a five storey steel frame structure base isolated according to GERB’s Spring-Dashpot System. IZIIS report 83-242
Jurukovski D, Mamucevski D, Tashkov Lj, Hadzi-Tosev N, Trajkovski V (1984b) Shaking table tests of a five storey steel frame model fixed at the base and isolated by rubber elements. IZIIS report 84-123
Jurukovski D, Mamucevski D, Tashkov Lj, Hadzi-Tosev N, Trajkovski V (1984c) Shaking table tests of a five storey steel frame model isolated by GERB vibration isolation elements. IZIIS report 84-128
Jurukovski D, Mamucevski D, Bojadziev M (1986a) Report on testing of seismic and dynamic stability of high voltage isolator type RVZ-420-1 manufactured by Rade Koncar – Zagreb. IZIIS report 86-141
Jurukovski D, Mamucevski D, Trajkovski V (1986b) Report on testing of seismic stability of high voltage circuit breaker type SFE-13 manufactured by Energoinvest – Sarajevo. IZIIS report 86-34
Jurukovski D, Mamucevski D, Bojadziev M, Krstevska L (1989a) Report on seismic withstand testing of high voltage isolator type RS-4202 manufactured by MINEL Belgrade. IZIIS report 89-29
Jurukovski D, Tashkov Lj, Petkovski M, Gavrilovic P (1989b) Basic and applied research study for seismic modelling of mixed reinforced concrete masonry buildings: shaking table test of reduced scale model. IZIIS report 89-66
Jurukovski D, Tashkov Lj, Petkovski M, Mamucevski D (1989c) Basic and applied research study for seismic modelling of mixed reinforced concrete masonry buildings: shaking table test of reduced scale repaired model. P IZIIS report 89-75/1
Jurukovski D, Tashkov Lj, Petkovski M, Krstevska L (1991a) Basic and applied research study for seismic modelling of mixed reinforced concrete masonry buildings: shaking table test of reduced scale model strengthened by Reinforced Concrete Central Core. IZIIS report 91-92
Jurukovski D, Tashkov Lj, Petkovski M, Mamucevski D (1991b) Basic and applied research study for seismic modelling of mixed reinforced concrete masonry buildings: shaking table test of reduced scale model strengthened by External Reinforced Concrete Walls. IZIIS report 91-01
Jurukovski D, Tashkov Lj, Petkovski M, Krstevska L (1992) Basic and applied research study for seismic modelling of mixed reinforced concrete masonry buildings – shaking table test of reduced scale model strengthened by Reinforced Concrete Central Core after repairing by Cement Mortar Injection. IZIIS report 92-27
Jurukovski D, Tashkov Lj, Bojadziev M, Garevski M, Mamucevski D (1993) Shaking table test of 1/30 scale model of Palasport in Bologna: model with wooden roof-model 1. IZIIS report 93-48
Jurukovski D, Tashkov Lj, Bojadziev M, Mamucevski D (1994) Shaking table test of 1/30 scale model of Palasport in Bologna: model with continuous shell roof – model 2. IZIIS report 94-17
Jurukovski D, Gavrilovic P, Tashkov Lj, Krstevska L, Rakicevic Z, Petrusevska R (1996a) Experimental investigation of seismic stability of prefabricated facade system with thin stone claddings. IZIIS report 96-76
Jurukovski D, Tashkov Lj, Bojadziev M (1996b) Dynamic testing of the Alma-Ata Bank Model in scale 1/11 on shaking table. IZIIS report 96-02
Krstevska L, Tashkov Lj, Gramatikov K (2007) FP6 project PROHITECH – shaking table testing of Mustafa-Pasa Mosque model. Final report. IZIIS March 2007
Mamucevski D, Bojadziev M (1992) Vibration tests of bimetallic relay TRM-12 manufactured by Rade Koncar – Skopje. IZIIS report 92-18
Mamucevski D, Jurukovski D (1987a) Seismic and dynamic testing of valves for nuclear power plants manufactured by Energoinvest – Sarajevo. IZIIS report 87-98
Mamucevski D, Jurukovski D (1987b) Experimental testing of elements for elastic foundation of facilities and devices produced by Jugoturbina – Karlovac. IZIIS report 87-92
Mamucevski D, Jurukovski D (1988) Experimental seismic and vibration tests of controlling drives produced by Energoinvest-Sarajevo. IZIIS report 88-104
Mamucevski D, Jurukovski D (1989) Experimental seismic investigations performed for electromechanical drives manufactured by Energoinvest – Sarajevo: experimental results for the EMPN 250-10-C-0/KK-0-G-1-9-0-0 drive. IZIIS report 89-44
Mamucevski D, Krstevska L (1988a) Seismic and dynamic testing of needle valves for nuclear power plants produced by ‘Prva Iskra’ – Baric. IZIIS report 88-44
Mamucevski D, Jurukovski D, Micajkov S (1985a) Dynamic experimental testing of vehicles produced by Rakovica in Belgrade using a biaxial shaking table. IZIIS report 85-98
Mamucevski D, Jurukovski D, Percinkov S (1985b) Seismic and dynamic testing of valves for nuclear power plants produced by Energoinvest – Sarajevo. IZIIS report 85-36
Mamucevski D, Bojadziev M, Jurukovski D (1986a) Experimental seismic and dynamic testing of the high-voltage separating contactor type RVZ-420-1 manufactured by Rade Koncar – Zagreb. IZIIS report 86-144
Mamucevski D, Jurukovski D, Percinkov S (1986b) Experimental determination of the dynamic characteristics of hydraulic dampers manufactured by GOSA. IZIIS report 86-105
Mamucevski D, Petkovski M, Jurukovski D (1986c) Experimental seismic and dynamic tests of a low voltage control panel type VM16 VMF6 produced by ‘Rade Koncar’ Zagreb. IZIIS report 86-96
Mamucevski D, Jurukovski D, Petkovski M (1988b) Experimental seismic and dynamic testing of the current transformer A64-420 produced by Rade Koncar-Zagreb. IZIIS report 86-49
Mamucevski D, Stamatovska S, Petkovski M, Jurukovski D (1988c) Experimental investigations of the pressure and differential pressure transmitter P 151 manufactured by ATM – Zagreb. IZIIS report 88-36
Mamucevski D, Bojadziev M, Percinkov S (1990) Experimental investigation of the vibration effects on the distributing panel OR-1 manufactured by Rade Koncar – Skopje. IZIIS report 90-27
Proceedings of 14th European conference on Earthquake Engineering, 2010, Ohrid, Macedonia
Proceedings of 14th world conference on Earthquake Engineering, 2008, Beijing, China
Proceedings of 5th world conference on structural control and monitoring, 2010, Tokyo, Japan
Rakicevic Z (2007) Proof tests on a shaking table of a new brick laying system patented by PREXO SEALING, Norway. IZIIS report 2007-26
Rakicevic Z (2008) Seismic qualification of current transformer IST 123 kV manufactured by ENERGOINVEST-RAOP, Sarajevo by Time History Shaking Table Testing. IZIIS report 2008-58
Rakicevic Z, Jurukovski D (2001) Optimum design of passive controlled steel frame structures. IZIIS report 2001-59
Rakicevic Z, Matevski V (2009) Seismic qualification by Time History Shaking Table Testing of oil-immersed current transformer AGU-525, capacitor voltage transformer VCU–765, combined instrument transformer VAU–420 and voltage transformer VPU–525, manufactured by KONCAR instrument transformers Inc. IZIIS report 2009-42, 43, 59 and 60
Rakicevic Z, Zlateska A, Golubovski R, Matevski V (2009a) Shaking table testing of Wienerberger two storey masonry models without and with antiseismic devices. IZIIS report 2009-41
Rakicevic Z, Zlateska A, Jurukovski D (2009b) Shaking table effectiveness testing of GERB PDD (Prestressed Damping Device) Control System. IZIIS Report 2009-40
Ristic D, Tashkov Lj, Micov V, Bojadziev M, Popovski M (1992) Investigation of the dynamic behaviour of a bridge model with built-in neoprene bearings under actual earthquake effects simulated by a seismic shaking table. IZIIS report 92-44
Structural Control and Health Monitoring (2008-2010) vols 15–17. Wiley
Tashkov Lj, Krstevska L (2007) Shaking table test of a segment of brick-masonry wall at Beauharnois Powerhouse. IZIIS report 2007-51/1
Tashkov Lj, Krstevska L (2009) Seismic qualification of Lindner raised floors type NORTEC G30 ST Germany. IZIIS report 2009-20
Tashkov Lj, Petkovski M (1986) Experimental determination of the dynamic characteristics of the high voltage circuit breaker K3AT3 manufactured by Rade Koncar – Zagreb. IZIIS report 86-112
Tashkov Lj, Bojadziev M, Krstevska L (1988) Testing of damping efficiency of the damper type 297.04.000 for conductor 490/65 by using a two-component shaking table. IZIIS report 88-64
Tashkov Lj, Krstevska L, Gavrilovic P (1992a) Study for seismic strengthening conservation and restoration of churches dating from the Byzantine Period (9th–14th century) in Macedonia vol 9 shaking table test of models. IZIIS report 92-71/9
Tashkov Lj, Petkovski M, Krstevska L, Mamucevski D (1992b) Research study for evaluation of seismic resistance of the 105-storey Ryugyong Hotel in Pyongyang DPR Korea vol 4: shaking table test of 1/40 scale model of the building. IZIIS report 92-06
Tashkov Lj, Jurukovski D, Mamucevski D, Rakicevic Z, Stamatovska S (1994) Shaking table test of key lock systems products of Heerum – Germany under seismic and resonant conditions. IZIIS report 94-51/2
Tashkov Lj, Tomovski I, Rakicevic Z (2000) Seismic qualification on high voltage circuit breaker type SFL 13 three pole drive manufactured by ELOP-IRCE, Sarajevo. IZIIS report 2000-23
Tashkov Lj, Kokalanov G, Krstevska L, Aleksovska M (2008) FP6 project PROHITECH – seismic upgrading of Byzantine church by reversible innovative base isolation ALSC floating-sliding system. WP12 final report, IZIIS Aug 2008
Tashkov Lj, Krstevska L, Gramatikov K (2008a) FP6 project PROHITECH – shaking table testing of Fossanova model. Final report, IZIIS report March 2008
Tashkov Lj, Krstevska L, Gramatikov K (2008b) FP6 project PROHITECH – shaking table testing of Saint Nicholas model. Final report, IZIIS report July 2008
Acknowledgments
The authors express their gratitude to IZIIS and the Dynamic Testing Laboratory for making the publishing of this paper possible.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer Science+Business Media B.V.
About this paper
Cite this paper
Rakicevic, Z.T., Bogdanovic, A., Jurukovski, D. (2012). Structural and Behaviour Constraints of Shaking Table Experiments. In: Fardis, M., Rakicevic, Z. (eds) Role of Seismic Testing Facilities in Performance-Based Earthquake Engineering. Geotechnical, Geological, and Earthquake Engineering, vol 22. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-1977-4_3
Download citation
DOI: https://doi.org/10.1007/978-94-007-1977-4_3
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-1976-7
Online ISBN: 978-94-007-1977-4
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)