Abstract
This chapter introduces the state-of-the-art in the main topics covered in the book: energy harvesting, with special interest in the body energy harvesting sources, biosensors, and finally the electronics for them. These are the main aspects to consider in the envisaged conception of the Self-Powered architecture for subcutaneous detector device.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
C. Sauer, N. Thakor, Power harvesting and telemetry in CMOS for implanted devices. IEEE Trans. on Circuits and Syst. 52(12), 2605–2613 (Dec 2005)
Y. Li, J. Liu, A 13.56 MHz RFID Transponder front-end with merged load modulation and voltage doubler-clamping rectifier circuits. IEEE Int. Sym. on Circuits and Syst. 5095–5098 (2005)
K. Myny, et al, An inductively coupled 64b organic RFID tag Operating at 13,56 MHz with a data rate of 787b/s. IEEE Int. Solid-State Circuits Conf. 290–614 (2008)
A. Gore, et al., A multi-channel femtoampere-sensitivity conductometric array for biosensing applications. 28th IEEE Eng. in Medicine and Biology Science Conference, pp. 6489–6492, 2006
M. R. Haider, et al., A low-power processing unit for in vivo monitoring and transmission of sensor signals. Sensors & Transducers J. 84(10) 1625–1632 (Oct 2007)
J. Colomer-Farrarons; P. Miribel-Català; J. Samitier; M. Arundell; I. Rodríguez, Design of a miniaturized electrochemical instrument for in-situ O2 monitoring. (Proceedings Paper Spie’09), VLSI Circuits and Systems IV, Microtechnologies for the New Millennium, Volumen 7363 (2009)
Transdermal Drug Delivery Promises To Eliminate Needles. http://www.popularmechanics.com/science/health_medicine/1281106.html
C.M. Zierhofer, E.S. Hachmair, Geometric approach for coupling enhancement of magnetically coupled coils. IEEE Trans. Biomed. Eng. 43, 708–714 (1996)
M. Sawan, H. Yamu, J. Coulombe, Wireless smart implants dedicated to multichannel monitoring and microstimulation. IEEE Circuits Syst. Mag. 5, 21–39 (2005)
C. Sauer, M. Stanacevic, G. Cauwenberhs, N. Thakor, Power harvesting and telemetry in CMOS for implanted devices. IEEE Trans. Circuits Syst. 52(12), 2605–2613 (Dec 2005)
Y. Li, J. Liu, A 13.56 MHz RFID transponder front-end with merged load modulation and voltage doubler-clamping rectifier circuits. IEEE International Symposium on Circuits and Systems, 5095–5098 2005
K. Myny, S. Van Winckel, S. Steudel, P. Vicca, S. De Jonge, M.J. Beenhakkers, C.W Sele, N.A.J.M. van Aerle, G.H.Gelink, J. Genoe, P. Heremans, An inductibely-coupled 64b organic RFID tag Operating at 13,56 MHz with a data rate of 787b/s. IEEE International Solid-State Circuits Conference, pp. 290–614 (2008).
O. Meirik, Implantable contraceptives for women. Contraception. 65(1), 1–2 (2002)
O. Meirik et al, Implantable contraceptives for women. Hum Reprod Update. 9(1), 49–59 (2003)
S. Alepuz, S. Busquets-Monge, J. Bordonau, J. Gago, D. Gonzalez, J. Balcells, Interfacing renewable energy sources to the utility grid using a three-level inverter. IEEE Trans. Ind. Electron. 53(5), 1504–1511 (Oct 2006)
J.M. Carrasco, L.G. Franquelo, J.T. Bialasiewicz, E. Galvan, R.C. PortilloGuisado, M.A.M. Prats, J.I. Leon, N. Moreno-Alfonso, Power-Electronic systems for the grid integration of renewable energy sources: A survey. IEEE Trans. Ind. Electron. 53(4), 1002–1016 (June 2006)
J. Schonberger, R. Duke, S.D. Round, DC-bus signaling: A distributed control strategy for a hybrid renewable nanogrid. IEEE Trans. Ind. Electron. 53(5), 1453–1460 (Oct. 2006)
L. Collins, Harvest for the world. IEEE Power Eng. 20(1), 34–37 (Feb–March 2006)
J.A. Paradiso, T. Starner, Energy scavenging for mobile and wireless electronics, IEEE Pervasive Comput. 4(1), 18–27 (Jan–March 2005)
E.M. Yeatman, Energy scavenging for wireless sensor nodes, in Proceedings. of the 2nd International Workshop on Advances in Sensors and Interface, 1–4 (2007)
S. Roundy, D. Steingart, L. Frechette, P. Wright, J. Rabaey, Power sources for wireless sensors networks, in Proceedings. of the 1st European Workshop on Wireless Sensors Networks, 1–17 (Jan.2004)
D. Niyato, E. Hossain, M.M. Rashid, V.K. Bhargava, Wireless sensor networks with energy harvesting technologies: A game-theoretic approach to optimal energy management. IEEE Wirel. Commun. 14(4), 90–96 (Aug 2007)
N.S. Shenck, J.A. Paradiso, Energy scavenging with shoe-mounted piezoelectrics. IEEE Micro. 21(3), 30–42 (May–June 2001)
T. Starner, J.A. Paradiso, Human-generated power for mobile electronics, ed. by C. Piguet. Low-Power Electronics Design, (CRC Press, 2004), Chapter 45, pp. 1–35
M.S.M. Soliman, E.F. El-Saadany, R.R. Manssur, Electromagnetic MEMS Based Micro-Power Generator, in Proceedings of the IEEE International Symposium on Industrial Electronics, Vol.4 (Jul 2006), pp. 2747–2753
X. Cao, W. Chiang, Y. King, Y. Lee, Energy harvesting circuit with feedforward and feedback DC–DC PWM boost converter for vibration power generator system. IEEE Trans. Power Electron. 22(2) 679–685, (March, 2007)
S. Meninger, J.O. Mur-Miranda, R. Amirtharajah, A. Chandrakasan, J.H. Lang, Vibration-to-electric energy conversion. IEEE Trans. Very Large Scale Integration (VLSI) Systems. 9(1), 64–76 (Feb.2001)
N. Ben Amor, O. Kanoun, Investigation to the Use of Vibration Energy for Supply of Hearing Aids, in Proceedings of the IEEE Instrumentation and Measurement Technology Conference, (May 2007), pp. 1–6
Y. Ammar, A. Buhrig, M. Marzencky, B. Charlot, S. Basour, K. Matou, M. Renaudin,Wireless sensor network node with asynchronous architecture and vibration harvesting micro power generator, in Proceedings of the SOC-EUSAI Conference, (Oct 2005), pp. 287–292
E.K. Reilly, E. Carleton, P.K. Wright, Thin film piezoelectric energy scavenging systems for long term medical monitoring, in Proceedings of the IEEE International Workshop on Wearable and Implantable Body Sensor Networks, (2006), p. 4
D. Puccinelli, M. Haenggi, Wireless sensor networks: Applications and challenges of ubiquitous sensing. IEEE Circuits Syst. Mag. 3(3), 19–29 (2005)
F. Kocer, P.M. Walsh, and M.P. Flynn, Wireless, Remotely Powered Telemetry in 0.25 μm CMOS, Radio Frequency Integrated Circuits Symposium, (IEEE Press, FortWorth, Texas, 2004), 339–342
N. Cho et al., A 8-μW, 0.3 mm2 RF-Powered Transponder with Temperature Sensor for Wireless Environmental Monitoring, in Proceedings IEEE International Symposium on Circuits and Systems, (May 2005), pp. 4763–4766
S.J. Miller-Smith, New Chip Can Read Your Pet’s Temperature, Darwin Veterinary Center. http://www.darwinvets.plus.com/topical/biothermo.htm
M. Ferrari, V. Ferrari, D. Marioli, A. Taroni, Modeling, fabrication and performance measurements of a piezoelectric energy converter for power harvesting in autonomous microsystems. IEEE Trans. Instrum. Meas. 55(6) 2096–2101 (Dec 2006)
C.B. Williams, R.B. Yates, Analysis of a micro-electric generator for microsystems. Sens. Actuators A. 52, 8–11 (1996)
M. El-hami, P. Glynne-Jones, N.M. White, M. Hill, S. Beeby, E. James, A.D. Brown, and J.N. Ross, Design and fabrication of a new vibration-based electromechanical power generator, Sens. Actuators A. 92 335–342 (2001)
T. Starner, Human-powered wearable computing. IBM Syst. J. 35 618–629 (1996)
http://www.microsoft.com/presspass/ofnote/11-02worldin2003.mspx
J. Brufau, M. Puig, Piezoelectric energy harvesting improvement with complex conjugate impedance matching. J. Intell. Mater. Syst.Struct. 2009 pp. 597–608, (Sept 2008), DOI: 10.1177/1045389X08096051
M. Griot, Fundamentals of Vibration Isolation, http://www.mellesgriot.com
J.A. Paradiso, Systems for human-powered mobile computing, Proceedings of the 43rd annual Design Automation Conference Annual ACM IEEE Design Automation Conference, San Francisco, CA, SESSION: Session 37: Special session: beyond low-power design: environmental energy harvesting, 645–650 (2006)
S. Roundy, P.K. Wright, and K.S.J. Pister, Micro-electrostatic vibration-to-electricity converters proceedings of IMECE’02 2002 ASME international mechanical engineering congress & exposition New Orleans, Louisiana 17–22 (2002)
J.A. Paradiso, T. Starner, Energy scavenging for mobile and wireless electronics. IEEE Pervasive Comput. 4, 18–27 (2005)
J. Krikke, Sunrise for energy harvesting products, published by the IEEE CS and IEEE ComSoc 1536-1268/05/$20.00 © 2005 IEEE
M. Stordeur, I. Stark, Low Power Thermoelectric Generator – Self-Sufficient Energy Supply for Micro Systems, in Proceedings ICT’97 16th International Conferrence Thermoelectrics, (1997), pp.575–577
S. Roundy, P.K. Wright, J.M. Rabaey, Energy Scavenging for Wireless Sensor Networks (Kluwer Academic Publishers, Boston MA)
“Wireless Power Demonstrated”, Retrieved 12-09-2008 http://thefutureofthings.com/pod/250/wireless-power-demonstrated.html
Wireless electricity could power consumer, industrial electronics. MIT News. 2006-11-14. http://web.mit.edu/newsoffice/2006/wireless.html
Thermo Life Energy Co. http://www.poweredbythermolife.com/
T. Kazazian, A.J. Jansen, Eco-desing and human-powered products, proceedings of the Electronics Goes Green, (2004), pp. 6–10
FreePlay, To make energy available to everybody all of the time, http://www.freeplayenergy.com/about
N.S. Shenck, J. Paradiso, Energy scavenging with shoe-mounted piezoelectrics. IEEE Micro. 21(3), (May–June 2001) 30–42
WHMS – Wearable Health Monitoring Systems, Electrical and Computer Engineering, The University of Alabama in Huntsville, http://www.ece.uah.edu/~jovanov/whrms/
Toumaz http://www.toumaz.com/
C. Van Hoof, V Leonov, R.J.M Vullers, Thermoelectric and Hybrid Generators in Wearable Devices and Clothes, 6th International Workshop on Wearable and Implantable Body Sensor Networks, 2009. BSN 2009. 3–5 June 2009 195–200
Wearable Electronic Science. http://www.fibre2fashion.com/news/nanotechnology-news/newsdetails.aspx?news_id=70079
IMEC http://www2.imec.be
Health Care News. “Microsoft Partners With Implantable RFID Chip Maker VeriChip” http://www.rfidjournal.com/article/articleview/4477/1/1/
IUPAC Compendium of Chemical Terminology, International Union of Pure and Applied Chemistry: Research Triangle Park, NC, USA 2nd edn. (1997, 1992)
L.C. Clark Jr, C. Lyons, Electrode systems for continuous monitoring in cardiorascular surgery NY, Acad. Sci. 102, 29–45 (1962)
K. Dill, Biosens. Bioelectron. 20, 736–742 (2004)
M. Hiller, C. Kranz, J. Huber, P. Bauerle, W. Schuhmann, Amperometric biosensors produced by immobilization of redox enzymes at polythiophene-modified electrode surfaces. Adv. Mater. 8, 219–222 (1996)
A. Kros, W.F.M. Van Hovell, N.A.J.M. Sommerdijk, R.J.M. Nolte, Poly(3, 4-thylenedioxythiophene)-based glucose biosensors. Adv. Mater. 13,1555–1557 (2001)
P.A. Fiorito, S.I.C. De Torresi, Glucose amperometric biosensor based on the co-immobilization of glucose oxidase (Gox) and ferrocene in poly(pyrrole) generated from ethanol/water mixtures. J. Braz. Chem. Soc. 12, 729–733 (2001)
J. Patel, B. Kaminska, B. Gray, B. Gates,Electro-Enzymatic Glucose Sensor Using Hybrid Polymer Fabrication Process Electronics, Circuits and Systems, 2007. ICECS 2007. in Proceedings of the 14th IEEE International Conference on 11–14 Dec. (2007) pp. 403–406
X. Huang, S. Li, J. Schultz, Q. Wang, Q. Lin, A capacitively based MEMS affinity glucose sensor”, Proceedings of the International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS 2009, (21–25 June 2009), pp. 1457–1460
N.P, Rodrigues, H. Kimura, Y Sakai, T. Fujii, Cell-based Microfluidic biochip for electrochemical real-time monitoring of glucose and oxygen Solid-State Sensors, Actuators and Microsystems Conference. (10–14 June 2007) pp. 843–846
A. Rahman, G. Justin, A. Guiseppi-Wilson, A. Guiseppi-Elie, Fabrication and packaging of a dual sensing electrochemical biotransducer for glucose and lactate useful in intramuscular physiologic status monitoring Sens. J. IEEE 9 (12),(Dec 2009) 1856–1863
J. Xie; S. Wang; L. Aryasomayajula, V.K. Varadan, Material and electrochemical studies of platinum nanoparticle-coated carbon nanotubes for biosensing. Nanotechnology, 2007. IEEE-NANO 2007. 7th IEEE Conference, 2–5 Aug 2007, pp. 1077–1080
E.M.I. Ekanayake, D. Preethichandra, K. Kaneto, Fabrication and characterization of nano-structured conducting polymer electrodes for glucose biosensor applications. Industrial and information systems, 2007. ICIIS 2007. International conference, 9–11 Aug 2007, pp. 63–66
U. Ali, S.M. Nur, M. Willander, B. Danielsson, Glucose detection with a commercial MOSFET using a ZnO nanowires extended gate. IEEE Trans. Nanotechnol. 8(6), 678–683 (Nov 2009)
Bender, Sadik, Direct electrochemical immunosensor for polychlorinated biphenyls. Environ. Sci. Technol. 32, 788–797 (1998)
G. Farace, G. Lillie, T. Hianik, P. Payne and P. Vadgama, Reagentless biosensing using electrochemical impedance spectroscopy. Bioelectrochemistry 55,1–3 (2002)
E. Katz, I. Willner, Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors. Electroanalysis 15, 913–947 (2003)
D. Laureyn, P. Nelis, K. Van Gerwen, L. Baert, R. Hermans, J.J. Magnee, G. Maes, Nanoscaled interdigitated titanium electrodes for impedimetric biosensing. Sens. Actuators B-Chem. 68, 360–370 (2000)
Lillie, P. Payne, P. Vadgama, Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing. Sens. Actuators B-Chem. 78, 249–256 (2001)
Y. Liu, S. Chakrabartty, E.C Alocilja, Fundamental building blocks for molecular biowire based forward error-correcting biosensors. Nanotechnology 18 424-017 (6pp). (2007)
J. Colomer-Farrarons, P. Miribel-Català, A. Saiz-Vela, J. Samitier, in Proceedings. of the 16th IEEE International Conference on Very Large Scale Integration VLSI – SOC, A 50 μW low-voltage CMOS Biopotentiostat for low frequency Capacitive Biosensor. (Rodhas, Greece, 2008)
A. Gore, S. Chakrabartty, S. Pal, E. Alocilja, A multi-channel femtoampere-sensitivity conductometric array for biosensing applications, Proceedings of the Annaual InternationalConference on IEEE Engineeringin Medicine and Biological Society. 2006
S.V. Dzyadevych et al. Electrochemical enzyme biosensors (2006), ISBN: 966-02-4200-X
E.A. Johannessen, L. Wang, L. Cui, T. Tang, A. Astaras, M. Ahmadian, J.M. Cooper, Implementation of multichannel sensors for remote biomedical measurements in a microsystems format. IEEE Trans. Biomed. Eng. (2004)
P. Mohseni, K. Najafi, S.J. Eliades, W. Xiaoqin, Wireless multichannel biopotential recording using an integrated FM telemetry circuit. Neural Syst. Rehabil. Eng., IEEE Trans. 13(3), 263–271 (Sept 2005)
K. Murari, C.M. Sauer, M. Stanacevic, G. Cauwenberghs, N. Thakor, Wireless Multichannel Integrated Potentiostat for Distributed Neurotransmitter Sensing Engineering in Medicine and Biology 27th Annual Conference Shanghai, China, Sept 1–4 2005
R. Thewes, F. Hofmann, A. Frey, B. Holzapfl, M. Schienle, C. Paulus, P. Schindler, G. Eckstein, C. Kassel, M. Stanzel, R. Hintsche, E. Nebling, J. Albers, J. Hassman, J. Schülein, W. Goemann, W. Gumbrecht, Sensor arrays for fully-electronic DNA detection on CMOS IEEE international solid-state circuits conference, Section 21.2, 2002
E. Ghafar-Zadeh, M. Sawan, D. Therriault, CMOS based capacitive sensor laboratory-on-chip: a multidisciplinary approach. Analog Integrated Circuits and Signal Processing. 59(1), 1–12 (April 2009)
C. G. Zoski, Handbook of Electrochemistery, Elseiber, 2007, ISBN: 0-444-51958-0
C. Myung-suk, L. Sang-won, K. Jong-chul, C. Jun-dong, K. Jin-kwon; S. Hang-sik; L. Myung-ho; C. Un-sun; K. Jae-seok. Implantable Bio system design for displacement measurement of living life. Proc. 9th Int. Conf. Advanced Communication Technol. 1, 12–14 299–304 (Feb 2007)
K. Kitamori, Micro and nano chemical system on chip. TRANSDUCERS 2007. International Solid-State Sensors, Actuators and Microsystems Conference, 2007. 10–14 June 2007 11–16
W. Chung, A.C. Paglinawan, Y. Wang, T. Kuo, A 600μW Readout circuit with potentiostat for amperometric chemical sensors and glucose meter applications. IEEE conference on electron devices and solid-state circuits, 2007. EDSSC 2007. 20–22 Dec 2007 pp. 1087–1090
A. Lasia. Electrochemical impedance spectroscopy and its applications, Modern Aspects of Electrochemistry. Vol. 32 (Kluwer Academic/Plenum Publishers, New York, 1999), Chapter.2, p. 143
R.J. Reay, S.P. Kounaves, G. Kovacs, An integrated CMOS potentiostat for miniaturized electroanalytical instrumentation, Digest of Technical Papers of the 1994 IEEE International 41st ISSCC Solid-State Circuits Conference, 16–18 Feb 1994 162–163
T.D. Strong, S.M. Martin, R.F. Franklin, R.B. Brown, Integrated electrochemical neurosensors, Proceedings of the IEEE International Symposium on Circuits and Systems, 2006. ISCAS 2006. (21–24 May 2006) p. 4 pp. 4110–4113
Martin, S.M., Gebara, F.H., Larivee, B.J., Brown, R.B. A CMOS-integrated microinstrument for trace detection of heavy metals. IEEE J. Solid-State Circuits. 40(12), 2777–2786 (Dec 2005)
European Commission, Groundwater at risk: Managing the water under us, DG Environment, (2008)
I.M. Petayev, Plasma oxygen during cardioplumonary bypass: a comparison of blood levels woth oxygen present in plasma lipid. Clin. Sci. 94(1), 35–41 (1998)
S.M. Park, J.S. Yoo. Electrochemical impedance spectroscopy for better electrochemical measurements. Anal. Chem. 75(21), 455A–461A (2003)
A.D’. Amico et al., Low-voltage low-power integrated analog lock-in amplifier for gas sensor applications. Sens. Actuators B: Chem. (2009), doi:10.1016/j.snb.2009.01.046
M. Min, T. Parve, Improvement of lock-in electrical bio-impedance analyzer for implantable medical devices. IEEE Trans. Instrum. Meas. 56(3), 968–974 (June 2007)
H.A. Wolpert, Use of continous glucose monitoring in the detection and prevention of hypoglycemia, J. Diabetes Sci. Technol. 1(1), 146–150 (Jan 2007)
http://www.inhabitat.com/2008/12/11/tokyo-subway-stations-get-piezoelectric-floors/
L.A. Cantarero, J.E. Butler, J.W. Osborne, The adsorptive characteristics of proteins for polystyrene and their significance in solid-phase immunoassays Anal. Biochem. 105, 375–382 (1980)
M.M. Teymoori, H. Asadollahi, MEMS Based Medical Microsensors Computer and Electrical Engineering, 2009. ICCEE ’09. 2nd International Conference on Vol. 1 (28–30 Dec 2009) pp. 158–162
Y.J. Lee, J.D. Kim, J.Y. Park, Flexible enzyme free glucose micro-sensor for continuous monitoring applications. Solid-State Sensors, Actuators and Microsystems Conference, 2009. TRANSDUCERS 2009. International 21–25 June 2009 pp. 1806–1809
J.D. Goud, P.M. Raj, Jin Liu, R. Narayan, M. Iyer, R. Tummala, Electrochemical Biosensors and Microfluidics in Organic System-on-Package Technology Electronic Components and Technology Conference, 2007. ECTC ’07. Proceedings 57th. May 29–June 1 2007 pp. 1550–1555
E. Carnes, E. Wilkins, The development of a new, rapid, amperometric immunosensor for the detection of low concentrations of bacteria part I: Design and detection system and applications. Am. J. Appl. Sci. 2 and 3, 597–606 (2005)
H. Lhermet. et al., Efficient Power Management Circuit: Thermal Energy Harvesting to Above-IC Microbattery Energy Storage, ISSCC Digest of Technical Papers, pp. 62–63, Feb 2007
H. Shao et al., An inductor-less micro solar power management system design for energy harvesting applications. IEEE international symposium on circuits and systems, May 2007, pp. 1353–1356
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media B.V.
About this chapter
Cite this chapter
Colomer-Farrarons, J., Miribel-Català, P.L. (2011). Introduction. In: A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-0686-6_1
Download citation
DOI: https://doi.org/10.1007/978-94-007-0686-6_1
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-0685-9
Online ISBN: 978-94-007-0686-6
eBook Packages: EngineeringEngineering (R0)