Abstract

The paper provides an overview of recent developments and emerging solutions for high-performance damage-control seismic resisting systems, based on unbonded post-tensioned techniques. Several alternative arrangements for dry jointed ductile connections have been developed and extensively tested in the laboratory, for either precast concrete and, more recently, laminated timber structures, prior to being successfully adopted into real on-site applications. The concept of external replaceable “plug&play” dissipaters, providing supplemental strength and dissipation capacity to the system, whilst acting as the only sacrificial fuses for the entire structure, is herein presented along with examples of practical implementation. Similarly, the potential of newly proposed technical solutions to reduce the floor damage by creating a “jointed” or articulated floor system, is discussed. Finally, a brief presentation of recent on-site applications of such systems, featuring some of the latest technical solutions developed in the laboratory, is given as a valuable example of a successful implementation of performance-based seismic design theory and technology in the real construction industry.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Amaris AD, Pampanin S, Bull DK, Carr AJ, (2008) Solutions to control and minimize floor damage in precast concrete buildings under severe earthquake loading, NZ Concrete Industry Conference, Rotorua, 2–4 October

    Google Scholar 

  2. Buchanan A, Pampanin S, Palermo A, Newcombe M (2009) Non-conventional multi-storey timber building using posttensioning. 11th international conference on non-conventional materials and technologies, Bath, UK

    Google Scholar 

  3. Cattanach A, and Pampanin S (2008) 21st century precast: the detailing and manufacture of NZ's first multi-storey PRESSS-Building, NZ Concrete Industry Conference, Rotorua

    Google Scholar 

  4. Englerkirk (2002) Design-construction of the paramount – a 39 story precast prestressed concrete apartment Building. PCI J 47(4):56–72

    Google Scholar 

  5. Fenwick RC, Megget LM (1993) Elongation and load deflection characteristics of reinforced concrete members containing plastic hinges. Bull NZ Nat Soc Earthq Eng 26(1):28–41

    Google Scholar 

  6. fib (2003) International federation for structural concrete. Seismic design of precast concrete building structures. Bulletin No. 27, Lausanne, 254 pp

    Google Scholar 

  7. Kam WY, Pampanin S, Palermo A, Carr A (2006) Advanced flag-shaped systems for high seismic performance. 1st European Conference on Earthquake Engineering Geneva, Switzerland

    Google Scholar 

  8. Kurama Y, Shen Q (2004) Posttensioned hybrid coupled walls under lateral loads. J Struct Eng ASCE 130(2): 297–309

    Article  Google Scholar 

  9. Kurama YC (2001) Seismic design of unbonded post-tensioned precast concrete walls with supplementary viscous damping. ACI Struct J 97(4):648–658

    Google Scholar 

  10. Marriott D, Pampanin S, Bull D, Palermo A (2008) Dynamic testing of Precast, post-tensioned rocking wall systems with alternative dissipating solutions. Bull NZ Soc Earthq Eng 41(2): 90–103

    Google Scholar 

  11. Marriott D, Pampanin S, Palermo A (2009) Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters. Earthq Eng Struct Dyn 38(3):331–354

    Article  Google Scholar 

  12. Matthews J, Bull D, Mander J (2003) Hollowcore floor slab performance following a severe earthquake. Procedings of fib symposium concrete structures in seismic regions, Athens, Greece

    Google Scholar 

  13. Newcombe M, Pampanin S, Buchanan A, Palermo A, (2008) Section analysis and cyclic behavior of post-tensioned jointed ductile connections for multi-storey timber buildings. J Earthq Eng Special Issue 12(S1):83–110

    Article  Google Scholar 

  14. NZS3101:2006 (2006) Appendix B: special provisions for the seismic design of ductile jointed precast concrete structural systems. Standards New Zealand, Wellington, NZ

    Google Scholar 

  15. Palermo A, Pampanin S, Buchanan AH, Newcombe M (2005) Seismic design of multi-storey buildings using laminated veneer lumber. Proceedings of the New Zealand Society of Earthquake Engineering Conference, Wairakei, New Zealand

    Google Scholar 

  16. Pampanin S (2005) Emerging solutions for high seismic performance of precast –prestressed concrete Buildings. J Adv Concr Technol 3(2):202–222

    Article  Google Scholar 

  17. Pampanin S (ed) (2010) “PRESSS Design Hanbook”, New Zealand Concrete Society, Wellington, NZ

    Google Scholar 

  18. Pampanin S, Amaris A, Akguzel U, Palermo A (2006) Experimental investigations on high-performance jointed ductile connections for precast frames. 1st European conference on earthquake engineering and seismology, Geneva, Switzerland

    Google Scholar 

  19. Pampanin S, Pagani C, Zambelli S (2004) Cable-stayed and suspended post-tensioned solutions for precast concrete frames: the Brooklyn System. NZ Concrete Industry Conference, Queenstown

    Google Scholar 

  20. Pampanin S, Palermo A, Buchanan AH, Fragiacomo M, Deam BL (2006) Code provisions for seismic design of multi-storey post-tensioned timber buildings, CIB W18, Florence, August

    Google Scholar 

  21. Priestley MJN (1996) The PRESSS program-current status and proposed plans for phase III. PCI J 41(2):22–40

    Google Scholar 

  22. Priestley MJN, Sritharan S, Conley JR, Pampanin S (1999) Preliminary results and conclusions from the PRESSS five-storey precast concrete test building. PCI J 44(6):42–67

    Google Scholar 

  23. Ranta Maunus A (1995) Laminated veneer lumber and other structural sections. In: Hans Blass et al. (eds) Timber Engineering STEP 1, 1st edn. Centrum Hout, The Netherlands

    Google Scholar 

  24. SEAOC Vision 2000 Committee (1995) Performance-based seismic engineering. Structural Engineers Association of California, Sacramento, CA

    Google Scholar 

  25. Smith T, Pampanin S, Buchanan M (2009) Post-tensioned timber building, construction, costs and business case study, ANIDIS Bologna 28 June – 2 July

    Google Scholar 

  26. Stanton JF, Stone WC, Cheok GS (1997) A hybrid reinforced precast frame for seismic regions. PCI J 42(2):20–32

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stefano Pampanin .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Netherlands

About this chapter

Cite this chapter

Pampanin, S. (2010). Damage-Control Self-Centering Structures: From Laboratory Testing to On-site Applications. In: Fardis, M. (eds) Advances in Performance-Based Earthquake Engineering. Geotechnical, Geological and Earthquake Engineering, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-90-481-8746-1_28

Download citation

Publish with us

Policies and ethics