Abstract
In medical pulse-echo ultrasound imaging, a constant sound speed of 1,540 m/s in soft tissues is assumed. When the actual speed is different the mismatch can lead to image distortions. Even if the assumed speed is correct, ultrasound images can be difficult to interpret due to image blurring and the presence of speckle. However, this can be improved by non-blind deconvolution if the point-spread function (PSF) is known. In clinical applications a sufficiently accurate estimate of the PSF is difficult to obtain because of the unknown properties (including speed of sound) of soft tissues. In this paper, we address two topics: first, we explore the sensitivity of our deconvolution algorithm to variations in the speed of sound in the tissue; second, we extend our deconvolution algorithm to enable it to adapt to (and estimate) an unknown sound speed. In the first topic, the results reveal that the deconvolution output is sufficiently sensitive to the accuracy of the sound speed that the speed itself can be estimated using deconvolution. However, qualitative assessment suggests that we may not need the exact speed of sound for successful deconvolution so long as the assumed speed does not deviate significantly from the true value. In the second topic, the goal is gradually to adapt the assumed sound speed to improve the deconvolution and eventually estimate the true sound speed. We tested our algorithm with in vitro phantoms where the estimation error was found to be +0.01 ± 0.60% (mean ± standard deviation). In addition to the speed estimation itself, our method has also proved capable of producing better restoration of the ultrasound images than deconvolution by an assumed speed of 1,540 m/s when this assumption is significantly in error.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ng, J., Prager, R., Kingsbury, N., Treece, G., Gee, A.: Modeling ultrasound imaging as a linear shift-variant system. IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 53(3), 549–563 (2006)
Ng, J., Prager, R., Kingsbury, N., Treece, G., Gee, A.: Wavelet restoration of medical pulse-echo ultrasound images in an EM framework. IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 54(3), 550–568 (2007)
Robinson, D.E., Ophir, J., Wilson, L.S., Chen, C.F.: Pulse-echo ultrasound speed measurements: Progress and prospects. Ultrasound Med. Biol. 17(6), 633–646 (1991)
Jensen, J.: Field: A program for simulating ultrasound systems. Med. Biol. Eng. Comput. Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging, vol. 34, pp. 351–353 (1996)
Shin, H.-C., Prager, R., Ng, J., Gomersall, H., Kingsbury, N., Treece, G., Gee, A.: Sensitivity to point-spread function parameters in medical ultrasound image deconvolution. Ultrasonics 49(3), 344–357 (2008)
Anderson, M.E., McKeag, M.S., Trahey, G.E.: The impact of sound speed errors on medical ultrasound imaging. J. Acoust. Soc. Am. 107(6), 3540–3548 (2000)
Acknowledgements
This work is supported by the UK Engineering and Physical Sciences Research Council (EPSRC) grant EP/E007112/1.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media B.V.
About this paper
Cite this paper
Shin, HC., Prager, R., Gomersall, H., Kingsbury, N., Treece, G., Gee, A. (2011). Medical Ultrasound Image Deconvolution. In: André, M., Jones, J., Lee, H. (eds) Acoustical Imaging. Acoustical Imaging, vol 30. Springer, Dordrecht. https://doi.org/10.1007/978-90-481-3255-3_42
Download citation
DOI: https://doi.org/10.1007/978-90-481-3255-3_42
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-3254-6
Online ISBN: 978-90-481-3255-3
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)