The use of totally implantable venous access devices in radiology may be associated with a number of complications, including occlusion of the system, infection, extravasation of contrast media into the soft tissues, sub-intimal venous or myocardial injection, or serious damage to the device itself due to the high-pressure administration of contrast medium by automatic injectors (so-called “power injectors”). In this chapter state-of-the-art knowledge on this topic is presented; results of experimental and clinical studies are fully discussed, focusing on preventive measures and educational needs.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
FDA-Center for Devices and Radiological Health (2009) Reminders from FDA regarding ruptured vascular access devices from power injection. http://www.fda.gov/MedicalDevices/-Safety/AlertsandNotices/TipsandArticlesonDeviceSafety/ucm070193.htm. Accessed 20 May 2011
Eakle M, Lange S (2010) Device safety. Power injectors put I.V. lines under pressure. http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/TipsandArticlesonDeviceSafety/ucm225493.htm Accessed 20 May 2011
Health Devices (2004) A high-pressure situation: conventional I.V. sets can burst when used with CT contrast injectors. Health Devices 33:100–102
ACR (2004) Manual on contrast, 5th edn. American College of Radiology, Reston VA
GAVeCeLT (2011) Consensus on the correct use of totally implantable venous access devices for diagnostic radiology procedures. J Vasc Access [Epub ahead of print] doi:10.5301/JVA.2011.7736
Bow EJ, Kilpatrick MG, Clinch JJ (1999) Totally implantable venous access ports systems for patients receiving chemotherapy for solid tissue malignancies: A randomized controlled clinical trial examining the safety, efficacy, costs, and impact on quality of life. J Clin Oncol 17:1267
Biffi R, Pozzi S, Pace U et al (2001) Is there a real advantage in utilizing central venous ports in oncology surgery? An analysis of the cost-effectiveness ratio. Tumori 87:S74–S75
Biffi R, de Braud F, Orsi F et al (1998) Totally implantable central venous access ports for long-term chemotherapy. A prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days. Ann Oncol 9:767–773
Chenecky C (2001) Satisfaction versus dissatisfaction with venous access devices in out-patient oncology: a pilot study. Oncol Nurs Forum 28:1613–1616
Gallieni M, Pittiruti M, Biffi R (2008) Vascular access in oncology patients. CA Cancer J Clin 58:323–346
Kaste SC, Young CW (1996) Safe use of power injection with central and peripheral venous access devices for pediatric CT. Pediatr Radiol 26:499–501
Herts BR, O’Malley CM, Wirth SL et al (2001) Power injection of contrast using central venous catheters: feasibility, safety, and efficacy. AJR 176:447–453
Sanelli PC, Deshmuki M, Ougorets I et al (2004) Safety and feasibility of using a central venous catheter for rapid contrast injection rates. AJR 183:1829–1834
Amaral JG, Traubici J, BenDavid G et al (2006) Safety of power injector use in children as measured by incidence of extravasation. AJR 187:580–583
Rigsby CK, Gasber E, Seshadri R et al (2007) Safety and efficacy of pressure-limited power injection of iodinated contrast media through central lines in children. AJR 188:726–732
Ruess L, Bulas DL, Rivera O, Markle BM (1997) In-line pressure generated in small-bore central venous catheters during power injection of CT contrast. Radiology 203:625–629
Eisenhauer EA, Therasse P, Bogaerts J et al (2009) New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). Eur J Cancer 45:228–247
Pittiruti M, Hamilton H, Biffi R et al (2009) ESPEN Guidelines on Parenteral Nutrition: Central Venous Catheters (access, care, diagnosis and therapy of complications). Clin Nutr 28:365–377
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Italia
About this chapter
Cite this chapter
Biffi, R. (2012). Power Technology: How to Safely Use Ports and Central Catheters to Deliver Contrast Medium in Radiology Procedures. In: Di Carlo, I., Biffi, R. (eds) Totally Implantable Venous Access Devices. Springer, Milano. https://doi.org/10.1007/978-88-470-2373-4_34
Download citation
DOI: https://doi.org/10.1007/978-88-470-2373-4_34
Publisher Name: Springer, Milano
Print ISBN: 978-88-470-2372-7
Online ISBN: 978-88-470-2373-4
eBook Packages: MedicineMedicine (R0)