Abstract

The extraction of chronically implanted pacemaker leads is a challenging problem. Recently, the development of new extraction techniques has renewed the interest in this particular field.

Keywords

Removal Procedure Lead Removal Pace Lead Lead Extraction Prophylaxis Group 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Furman S, Behrens M, Andrews C et al (1987) Retained pacelast year (51 leads) maker leads. J Thoracic Cardiovasc Surg 94: 770Google Scholar
  2. 2.
    Zerbe P, Ponizynski A, Dyszkiewicz W et al (1985) Functionless retained pacing leads in the cardiovascular system. Br Heart J 54: 76PubMedCrossRefGoogle Scholar
  3. 3.
    Bongiorni MG, Berti S, Paperini L et al (1990) Should all paced patients be treated with anticoagulants in order to prevent thromboembolism? In: Santini M, Pistoiese M, Alliegro A (ed) Progress in clinical pacing. Excerpta Medica, Amsterdam, pp 207–214Google Scholar
  4. 4.
    Pauletti M, Di Ricco G, Solfanelli S et al (1981) Venous obstruction in permanent pacemaker patients: an isotopic study. PACE 4: 36–42PubMedCrossRefGoogle Scholar
  5. 5.
    Robboy SJ, Harthorne JW, Leinbach RC et al (1969) Autopsy findings with permanent pervenous pacemakers. Circulation 39: 495–501PubMedGoogle Scholar
  6. 6.
    Rettig G, Doenecke P, Sen S et al (1979) Complications with retained transvenous pacemaker electrodes. Am Heart J 98: 587PubMedCrossRefGoogle Scholar
  7. 7.
    Parry G, Goudevenos J, Jameson S et al (1991) Complications associated with retained pacemakers leads. PACE 14: 1251PubMedCrossRefGoogle Scholar
  8. 8.
    Bilgutay AM, Jensen NK, Schmidt WR et al (1979) Incarceration of transvenous pacemaker electrode: removal by traction. Am Heart J 77: 377CrossRefGoogle Scholar
  9. 9.
    Wallace HW, Sherafat M, Blakemore WS (1970) The stubborn pacemaker catheter. Surgery 68: 914PubMedGoogle Scholar
  10. 10.
    Imparato AM, Kim GE 1972 Electrode complications in patients with permanent cardiac pacemakers. Arch Surg 105: 705PubMedCrossRefGoogle Scholar
  11. 11.
    Lee M, Chaux A, Matloff J (1977) Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. J Thorac Cardiovasc Surg 74: 433PubMedGoogle Scholar
  12. 12.
    Tallury VK, De Pasquale NP, Bruno MS et al (1972) Migration of retained transvenous electrode catheter. Arch Intern Med 130: 390PubMedCrossRefGoogle Scholar
  13. 13.
    Garcia-Jimenez A, Botana Albà CM, Gutierrez Cortes JM, Galban Rodriguez C, Alvarez Dieguez I, Navarro Pellejero (1992) Myocardial rupture after pulling out a tined atrial electrode with continuous traction. PACE 15: 5PubMedCrossRefGoogle Scholar
  14. 14.
    Byrd C, Schwartz S, Sivina M et al (1985) Technique for the surgical extraction of permanent pacing leads and electrodes. J Thorac Cardiovasc Surg 89: 142PubMedGoogle Scholar
  15. 15.
    Yarnoz MD, Attai LH, Furman S (1985) Infection of pacemaker electrode and removal with cardiopulmonary bypass. J Thorac Cardiovasc Surg 68: 43Google Scholar
  16. 16.
    Jarvinen A, Harjula A, Verkkala K (1986) Intrathoracic surgery for retained endocardial electrodes. Thorac Cardiovasc Surgeon 34: 94CrossRefGoogle Scholar
  17. 17.
    Fearnot N, Smith H, Goode L et al (1990) Intravascular lead extraction using locking stylets, sheaths and other techniques. PACE 13 (II): 1864PubMedCrossRefGoogle Scholar
  18. 18.
    Byrd CL, Schwartz SJ, Hedin NB et al (1990) Intravascular lead extraction using locking stylets and sheaths. PACE 13: 1871–1875PubMedCrossRefGoogle Scholar
  19. 19.
    Byrd CL, Schwartz SJ, Hedin NB (1991) Intravascular techniques for extraction of permanent pacemakers leads. J Thoracic Cardiovasc Surg 101: 989Google Scholar
  20. 20.
    Bongiorni MG, Petz E, Levorato D et al (1991) Removal of chronic leads for permanent pacing. Clinical experience with transvenous extractors. In: Antonioli GE (ed) Pacemaker leads 1991. Elsevier, Amsterdam, pp 289–294Google Scholar
  21. 21.
    Byrd CL, Schwartz SJ, Hedin NB (1992) Lead extraction: indications and techniques. Cardiol Clin 10: 735–748PubMedGoogle Scholar
  22. 22.
    Lee ME, Chaux A (1980) Unusual complications of endocardial pacing. J Thorac Cardiovasc Surg 80: 934–940PubMedGoogle Scholar
  23. 23.
    Reinhardt J, Alt E, Neuzner J et al (1993) Clinic pacemaker lead removal-using a new method in 38 patients with 61 implanted leads. Multicenter experience. PACE 16: 1175 (abstr)Google Scholar
  24. 24.
    Heidi JM, Neal EF, Byrd CL, Wilkoff BL et al (1994) Five-years experience with intravascular lead extraction. PACE 17: 2016–2020CrossRefGoogle Scholar
  25. 25.
    Bongiorni MG, Arena G, Soldati E, De Simone L (1994) A “step by step” protocol for leads extraction procedures: relation with success rate and complications. PACE 17/4 (II): 786 (abstr)Google Scholar

Copyright information

© Springer-Verlag Italia, Milano 1996

Authors and Affiliations

  • M. G. Bongiorni
    • 1
  • G. Arena
    • 1
  • E. Soldati
    • 1
  • G. Quirino
    • 1
  • F. Vernazza
    • 1
  • L. De Simone
    • 1
  • D. Levorato
    • 1
  1. 1.Servizio di Elettrostimolazione ed ElettrofisiologiaIstituto di Fisiologia Clinica, CNR-CREASPisaItaly

Personalised recommendations