Advertisement

Transoesophageal echodoppler: clinical experience and case report

  • G. Galimberti
  • A. Agosti
  • R. Muchada
Conference paper

Abstract

The accurate evaluation and maintenance of haemodynamic status of critically ill patients and/or high surgical patients is one of the most-important responsibilities of the anaesthesiologist and intensivist [1–4]. Haemodynamic monitoring consists of observing how the cardiovascular system responds to trauma, illness, injury, and therapeutic intervention. Despite continuous improvements in surgical and anaesthetic techniques, major surgery is often associated with complications occurring during the perioperative period. The ability to anticipate haemodynamic impairment in response to critical illness or surgical trauma and to detect adverse changes early is a major factor in preventing the development of a haemodynamic crisis. Despite this important issue, in the majority of patients undergoing non-cardiac surgery, we monitor the cardiovascular function only by the electrocardiographic signal, the invasive or non-invasive measurement of the arterial blood pressure and the continuous recording of the Sp02 and end-tidal CO2 (PetCO2). This monitoring is well recognized to be unable to detect the clinical or subchnical haemodynamic alterations during anaesthesia. In fact, in the face of a sudden intraoperative hypotension, in particular after the induction of anaesthesia, we cannot understand what is really happening because we do not know whether the hypotensive state is caused by a decrease of the total systemic vascular resistance (TSVR) due to vascular dilatation or there is a fall in the cardiac performance. Lastly, there may either be a myocardial depression with a low cardiac output or an increase/decrease of the TSVR. Thus, a lot of anaesthesiologists, almost automatically implement a dangerous lightening of anaesthesia, with the risk of awareness and removal of the autonomic nervous system protection and/or a quick refilling with normal saline or colloids. Despite the lack of a correct physiopathological diagnosis, both manoeuvres are often effective, probably because there is a real or relative hypovolemia in our patients and, thus, the blood volume restoration corrects the hypovolemia due to the vasodilatation during general anaesthesia. Furthermore, if the patients have a normal cardio-814 G. Galimberti, A. Agosti, R. Muchada vascular function, i.e., they are on the sloping part of the LVSW/LVEDP wave (LVSWi left ventricular systolic work, LVEDP left ventricular end-diastolic pressure), the refilling test increases the preload and consequently, by the Frank-Starling mechanism, the inotropic state. Cardiac output (CO) is a critical parameter ensuring the adequacy of tissue oxygenation. CO is the volume of blood ejected per minute. It is the product of the stroke volume (SV) times the heart rate (HR) and is expressed in liters per minute. SV is the amount of blood ejected per beat and it is determined by a combination of three factors: preload (the ventricular end-diastolic volume), afterload (the resistance against which the left ventricular ejects), and contractility (the strength of cardiac contraction). CO measurement by thermodilution was originally introduced by Fegler in anaesthetized dogs in 1954 [5] and subsequently in clinical practice in 1970 by several investigators [6, 7]. Right heart catheterization (RHC) (also known as pulmonary artery catheterization) is necessary to guide therapy in critically ill patients and to improve patient outcome [8]. Despite the adoption of practice guidelines [9] and the widespread use in hospitals around the world, pulmonary artery catheterization (PAC) has remained controversial and the debate continues about rational clinical use, estimation of cost-effectiveness and risk-benefit ratio [10]. PAC provides valuable diagnostic information regarding myocardial function, including CO as well as the determinants of SV, and in some instances, the adequacy of oxygenation. These parameters are provided either intermittently or are delayed in time. The clinical limitations of PAC are thus determined by balancing the benefits to the patients against the not negligible risks and costs associated with using the technique.

Keywords

Pulmonary Artery Catheterization Noncardiac Surgery Right Heart Catheterization Aortic Blood Flow Left Ventricular Ejection Time 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Zeldin RA (1984) Assessing cardiac risk in patients who undergo noncardiac surgical procedures. Can J Surg 27:402–404PubMedGoogle Scholar
  2. 2.
    Goldman L (1994) Quantitative aspects of clinical reasoning. In: Isselbacher KJ, Braunwald E, Wilson JD, et al (eds) Harrison’s principles of internal medicine, 13th edn McGraw-Hill, New York, pp 43–48Google Scholar
  3. 3.
    Goldman L (1995) Cardiac risk in noncardiac surgery: an update. Anesth Analg 80: 810–820PubMedGoogle Scholar
  4. 4.
    Mangano DT (1990) Perioperative cardiac morbidity. Anesthesiology 72:153–184PubMedCrossRefGoogle Scholar
  5. 5.
    Fegler G (1957) The reliability of the thermodilution method for determination of the cardiac output and the blood flow in central veins. Q J Exp Physiol 42:254–266PubMedGoogle Scholar
  6. 6.
    Ganz W, Swan HJC (1972) Measurement of blood flow by thermodilution. Am J Cardiol 29:241–246PubMedCrossRefGoogle Scholar
  7. 7.
    Forrester JS, Ganz W, Diamond G et al (1972) Thermodilution cardiac output determination with a single flow-directed catheter. Am Heart J 83: 306–311PubMedCrossRefGoogle Scholar
  8. 8.
    ElHs Rj, Gold J, Rees JR et al (1972) Computerized monitoring of cardiac output by thermal dilution. JAMA 220:507–511CrossRefGoogle Scholar
  9. 9.
    The American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization (1993) Practice guidelines for pulmonary arthery catheterization. Anesthesiology 78:380–384CrossRefGoogle Scholar
  10. 10.
    Connors A Jr, Speroff T, Dawson NV et al (1996) The effectiveness of right heart catheterization in the initial cae of critically ill patients. JAMA 18:889–897CrossRefGoogle Scholar
  11. 11.
    Allaria B, Dei PoU M, Rigoli A et al (1992) Non-invasive, invasive and low-invasivity cardiovascular monitoring systems. In: Gullo A (ed) Atti APICE. Fogliazza, Milano, pp 233–260Google Scholar
  12. 12.
    Siegel LC, Shaker SI, Martinez GM et al (1988) Simultaneous measurements of cardiac output by thermodilution, esophageal doppler, and electrical impedance in anesthetized patients. J Cardiothorac Anesth 2:590–595PubMedCrossRefGoogle Scholar
  13. 13.
    Muchada R, Cathignol D, Lavandier B et al (1988) Aortic blood flow measurement. Am J Noninvas Cardiol 2:24–31Google Scholar
  14. 14.
    Buhre W, Buhre K, Kazmaier S et al (2001) Assessment of cardiac preload by indicator dilution and transoesophageal echocardiography. Eur J Anaesthesiol 18:662–667PubMedGoogle Scholar
  15. 15.
    Berlot G, Galimberti G, Muchada R et al (2000) Determination of aortic blood flow using transoesophageal echodoppler (TED). A comparison to thermodilution. Minerva Anestesiol 66 [Suppl l]:443–447Google Scholar
  16. 16.
    Muder RR, Yu VL, Fang GD (1989) Community-acquired Legionnaires’disease. Semin Respir Infect 4:32–39PubMedGoogle Scholar
  17. 17.
    Carratala J, Gudiol F, Pallares R et al (1994) Risk factor for nosocomial Legionella Pneumophila pneumonia. Am J Respir Crit Care Med 149:625–629PubMedCrossRefGoogle Scholar
  18. 18.
    Roig J, Aguilar X, Ruiz J et al (1991) Comparative study of Legionella pneumophila and other nosocomial-acquired pneumonias. Chest 99:344–350PubMedCrossRefGoogle Scholar
  19. 19.
    Stout JE, Lu VL (1997) Legionellosis. N Engl J Med 337:682–687PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag Italia 2003

Authors and Affiliations

  • G. Galimberti
  • A. Agosti
  • R. Muchada

There are no affiliations available

Personalised recommendations