Effects of Electromagnetic Interference on Implanted Cardiac Devices

  • M. L. Blitzer
  • M. H. Schoenfeld

Abstract

Cardiac pacemakers and defibrillators are remarkable devices with the ability to provide marked symptom relief and life-saving therapy. An ever-expanding list of indications continues to enlarge the pool of patients who live with implantable devices. Intrinsic to the function of these devices is the ability to sense intra-cardiac signals. An unfortunate by-product is the potential for electromagnetic energy in the environment to interact with and disturb the normal functioning of these devices. This chapter will review the way electromagnetic interference (EMI) can affect cardiac devices and then discuss specific situations and optimal techniques to minimize the chance of untoward interaction.

Keywords

Electromagnetic Interference Transcutaneous Electric Nerve Stimulation Cardiac Pacemaker Implantable Cardiac Defibrillator Cardiac Device 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Pinski SL, Trohman RG (2002) Interference in implanted cardiac devices, Part I. PACE 25:1367–1381PubMedCrossRefGoogle Scholar
  2. 2.
    Ferrick KJ, Johnston D, Kim SG et al (1991) Inadvertant AICD inactivation while playing bingo. Am Heart J 121:206–207PubMedCrossRefGoogle Scholar
  3. 3.
    Mclvor ME, Reddinger J, Floden E et al (1998) Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices (SPICED TEAS). PACE 21:1847–1861CrossRefGoogle Scholar
  4. 4.
    Madigan JD, Choudhri AF, Chen J et al (1999) Surgical management of the patient with an implanted cardiac device: Implications of electromagnetic interference. Annals of Surgery 5:639–647CrossRefGoogle Scholar
  5. 5.
    Gimbel JR, Johnson D, Levine PA et al (1996) Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. PACE 19:913–919PubMedCrossRefGoogle Scholar
  6. 6.
    Sommer T, Vahlhaus C, Lauck G et al (2000) MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 215:869–879PubMedGoogle Scholar
  7. 7.
    Goldschlager N, Epstein A, Friedman P et al (2001) Environmental and drug effects on patients with pacemakers and implantable cardioverter/defibrillators: A practical guide to patient treatment. Arch Intern Med 161:649–655PubMedCrossRefGoogle Scholar
  8. 8.
    Pinski SL, Trohman RG (2002) Interference in implanted cardiac devices, Part II. PACE 25:1496–1509PubMedCrossRefGoogle Scholar
  9. 9.
    Eriksson M, Schuller H, Sjolund B (1978) Hazards from transcutaneous nerve stimulation in patients with pacemakers. Lancet 1:1319PubMedCrossRefGoogle Scholar
  10. 10.
    Philbin DM, Marieb MA, Aithal KH et al (1998) Inappropriate shocks delivered by an ICD as a result of sensed potentials from a transcutaneous electronic nerve stimulation unit. PACE 21:2010–2011PubMedCrossRefGoogle Scholar
  11. 11.
    Mugica J, Henry L, Podeur H (2000) Study of interactions between permanent pacemakers and electronic antitheft surveillance systems. PACE 23:333–337PubMedCrossRefGoogle Scholar
  12. 12.
    Hayes DL, Wang PJ, Reynolds DW et al (1997) Interference with cardiac pacemakers by cellular telephones. New Engl J Med 336:1473–1479PubMedCrossRefGoogle Scholar
  13. 13.
    Cooperman Y, Zarfati D, Laniado S (1988) The effect of metal detector gates on implanted permanent pacemakers. PACE 11:1386–1387CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Italia 2004

Authors and Affiliations

  • M. L. Blitzer
    • 1
  • M. H. Schoenfeld
    • 1
  1. 1.Cardiac Electrophysiology and Pacer Laboratory, Hospital of Saint RaphaelYale University School of MedicineNew HavenUSA

Personalised recommendations