Advertisement

Monitoring in Acute Brain Injury

  • E. G. McKeating
Conference paper

Abstract

Advances in technology have provided us with an array of monitors that may be used in the intensive care unit (ICU) to monitor patients with acute brain injury (Fig. 1). It is, however, particularly important when considering this topic, to remember that the brain will not function without the support of other body systems, e.g., the cardiovascular and respiratory systems. Proper discussion must therefore start with the basic principles of management and monitoring of the acutely ill patient.

Keywords

Single Photon Emission Compute Tomography Cerebral Perfusion Pressure Jugular Bulb Acute Brain Injury Severe Brain Injury 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Chesnut RM, Marshall LF, Klauber MR et al. (1993) The role of secondary brain injury in determining outcome from severe head injury. J Trauma 34:216–222PubMedCrossRefGoogle Scholar
  2. 2.
    Siesjo BK, Siesjo P (1996) Mechanisms of secondary brain injury. Eur J Anaesthes 13:247–268CrossRefGoogle Scholar
  3. 3.
    Chesnut RM (1995) Secondary brain insults after head injury: clinical perspectives. New Horiz 3:366–375PubMedGoogle Scholar
  4. 4.
    Jones PA, Andrews PJ, Midgley S, et al (1994) Measuring the burden of secondary insults in head-injured patients during intensive care. J Neurosurg Anesthesiol 6:4–14PubMedGoogle Scholar
  5. 5.
    Andrews PJD, Piper IR, Dearden NM, et al (1990) Secondary insults during intrahospital transport of head-injured patients. Lancet 335:327–330PubMedCrossRefGoogle Scholar
  6. 6.
    Recommendations for the transfer of patients with acute head injuries to neurosurgical units. (1996) The Neuroanaesthesia Society of Great Britain and Ireland and The Association of Anaesthetists of Great Britain and IrelandGoogle Scholar
  7. 7.
    Jeevaratnam DR, Menon DK (1996) Survey of intensive care of severely head injured patients in the United Kingdom. BMJ 312:944–947PubMedCrossRefGoogle Scholar
  8. 8.
    Rossi S, Buzzi F, Paparella A, et al (1998) Complications and safety associated with ICP monitoring: a study of 542 patients. Acta Neurochir [Suppl] (Wien) 71:91–93Google Scholar
  9. 9.
    Rosner MJ, Daughton S (1990) Cerebral perfusion pressure management in head injury. J Trauma 30:933–941PubMedCrossRefGoogle Scholar
  10. 10.
    Rosner MJ, Rosner SD, Johnson AH (1995) Cerebral perfusion pressure: management protocol and clinical results. J Neurosurg 83:949–962PubMedCrossRefGoogle Scholar
  11. 11.
    Chan KH, Miller JD, Dearden NM, et al (1992) The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injury. J Neurosurg 77:55–61PubMedCrossRefGoogle Scholar
  12. 12.
    Souter MJ, Andrews PJD (1996) Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury. Br J Anaesth 76:744–746PubMedCrossRefGoogle Scholar
  13. 13.
    Cormio M, Valadka AB, Robertson CS (1999) Elevated jugular venous oxygen saturation after severe head injury. J Neurosurg 90:9–15PubMedCrossRefGoogle Scholar
  14. 14.
    Sebel PS, Maynard DE, Major E, et al (1983) The cerebral function analysing monitor (CFAM). A new microprocessor-based device for the on-line analysis of the EEG and evoked potentials. Br J Anaesth 55:1265–1270PubMedCrossRefGoogle Scholar
  15. 15.
    Maynard DE (1967) EEG analysis using an analogue frequency analyser and a digital computer. Electroencephalogr Clin Neurophysiol 23:487PubMedGoogle Scholar
  16. 16.
    Murdoch-Eaton D, Darowski M, Livingston J (2001) Cerebral function monitoring in paediatric intensive care: useful features for predicting outcome. Dev Med Child Neurol 43:91–96PubMedCrossRefGoogle Scholar
  17. 17.
    Chan KH, Miller JD, Dearden NM (1992) Intracranial blood flow velocity after head injury: relationship to severity of injury, time, neurological status and outcome. J Neurol Neurosurg Psychiatry 55:787–791PubMedCrossRefGoogle Scholar
  18. 18.
    Chan KH, Dearden NM, Miller JD, et al (1993) Multimodality monitoring as a guide to treatment of intracranial hypertension after severe brain injury. Neurosurgery 32:547–553PubMedCrossRefGoogle Scholar
  19. 19.
    Fukuda O, Endo S, Kuwayama N, et al (1995) The characteristics of laser-Doppler flowmetry for the measurement of regional cerebral blood flow. Neurosurgery 36:358–364PubMedCrossRefGoogle Scholar
  20. 20.
    Edwards AD (1994) The clinical role of near infrared spectroscopy. J Perinat Med 22:535–539PubMedCrossRefGoogle Scholar
  21. 21.
    Kirkpatrick PJ, Smielewski P, Czosnyka M, et al (1995) Near-infrared spectroscopy use in patients with head injury. J Neurosurg 83:963–970PubMedCrossRefGoogle Scholar
  22. 22.
    McKeating EG, Monjardino JR, Signorini DF, et al (1997) A comparison of the Invos 3100 and the Critikon 2020 near-infrared spectrophotometers as monitors of cerebral oxygenation. Anaesthesia 52:136–140PubMedCrossRefGoogle Scholar
  23. 23.
    Kety SS (1972) Study of the cerebral circulation by means of inert diffusible tracers. Progr Brain Res 35:375–385CrossRefGoogle Scholar
  24. 24.
    Bidabe AM, Gense dB, Gin AM, et al (1990) Measurement of cerebral blood flow by the stable xenon computerized tomography method. J Neuroradiol 17:103–124PubMedGoogle Scholar
  25. 25.
    Wyper DJ (1993) Functional neuroimaging with single photon emission computed tomography (SPECT). Cerebrovasc Brain Metab Rev 5:199–217PubMedGoogle Scholar
  26. 26.
    Herscovitch P (1993) Evaluation of the brain by positron emission tomography. Rheum Dis Clin North Am 19:765–794PubMedGoogle Scholar
  27. 27.
    Filippi R, Reisch R, Mauer D, et al (2000) Brain tissue pO2 related to SjvO2, ICP, and CPP in severe brain injury. Neurosurg Rev 23:94–97PubMedGoogle Scholar
  28. 28.
    Gupta AK, Hutchinson PJ, AlRawi P, et al (1999) Measuring brain tissue oxygenation compared with jugular venous oxygen saturation for monitoring cerebral oxygenation after traumatic brain injury. Anesth Analg 88:549–553PubMedGoogle Scholar
  29. 29.
    Piper I, Spiegelberg A, Whittle I, et al (1999) A comparative study of the Spiegelberg compliance device with a manual volume-injection method: a clinical evaluation in patients with hydrocephalus. Br J Neurosurg 13:581–586PubMedCrossRefGoogle Scholar
  30. 30.
    Piper I, Dunn L, Contant C, et al (2000) Multi-centre assessment of the Spiegelberg compliance monitor: preliminary results. Acta Neurochir [Suppl] (Wien) 76:491–494Google Scholar
  31. 31.
    Mendelowitsch A (2001) Microdialysis: intraoperative and posttraumatic applications in neurosurgery. Methods 23:73–81PubMedCrossRefGoogle Scholar
  32. 32.
    Hillered L, Persson L (1999) Neurochemical monitoring of the acutely injured human brain. Scand J Clin Lab Invest 59:9–18CrossRefGoogle Scholar
  33. 33.
    Koura SS, Doppenberg EM, Marmarou A, et al (1998) Relationship between excitatory amino acid release and outcome after severe human head injury. Acta Neurochir [Suppl] (Wien) 71:244–246Google Scholar
  34. 34.
    Bullock R, Zauner A, Woodward JJ, et al (1998) Factors affecting excitatory amino acid release following severe human head injury. J Neurosurg 89:507–518PubMedCrossRefGoogle Scholar
  35. 35.
    Berger C, Annecke A, Aschoff A, et al (1999) Neurochemical monitoring of fatal middle cerebral artery infarction. Stroke 30:460–463PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag Italia 2002

Authors and Affiliations

  • E. G. McKeating
    • 1
  1. 1.Department of Neuroanaesthesia and Critical CareThe Royal Preston HospitalPrestonUK

Personalised recommendations