Abstract

The vast majority of conventional mapping techniques currently used involve the recording of electrical events from electrodes positioned at various intracardiac locations. This process requires catheter movement through multiple sites within the heart to obtain activation mapping and entrainment data at these places. Insight into the electrophysiological behavior of the heart is obtained by combining the information from the electrogram recording with anatomical information gathered from fluoroscopic images. Therefore, optimal positioning of catheters for electrophysiological studies and interventional procedures requires integration of a knowledge of cardiac anatomy and radiographic correlates of the main anatomic landmarks with their intracardiac electrograms [1]. But cardiac chambers and the catheters positioned inside them are three-dimensional structures represented by fluoroscopy in two-dimensional planes, and thereby we frequently misjudge the spatial relationships between them. By using sequential fluoroscopic views, we can try to determine more precisely the relative position of the catheters inside the heart chambers. Nevertheless, the processing of data to form an electrospatial representation of cardiac activation is a cumbersome task, highly dependent on the mental agility and memory of the operator.

Keywords

Catheter Ablation Atrial Flutter Fluoroscopy Time Ablation Management Reentrant Tachycardia 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Singer I (1999) Catheterization and electrogram recordings. In: Singer I (ed) Interventio-nal electrophysiology. Williams & Wilkins, Baltimore, pp 27–59Google Scholar
  2. 2.
    Haïssaguerre M, Jaïs P, Shah DC et al (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 339:659–666PubMedCrossRefGoogle Scholar
  3. 3.
    Nakagawa H, Shah N, Matsudaira K et al (2001) Characterization of reentrant circuit in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease: isolated channels between scars allow “focal” ablation. Circulation 103:699–709PubMedCrossRefGoogle Scholar
  4. 4.
    Marchlinski FE, Callans DJ, Gottlieb CD, Zado E (2000) Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation 101:1288–1296PubMedCrossRefGoogle Scholar
  5. 5.
    Rosenthal LS, Mahesh M, Beck TJ et al (1998) Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures. Am J Cardiol 82:451–458PubMedCrossRefGoogle Scholar
  6. 6.
    Wittkampf FHM, Wever EFD, Derksen R et al (1999) LocaLisa. New technique for real-time 3-dimensional localization of regular intracardiac electrodes. Circulation 99:1312–1317PubMedCrossRefGoogle Scholar
  7. 7.
    Kirchhoh P, Loh P, Eckardt L et al (2002) A novel nonfluoroscopic catheter visualization system (LocaLisa) to reduce radiation exposure during catheter ablation of supraventricular tachycardias. Am J Cardiol 90:340–344CrossRefGoogle Scholar
  8. 8.
    Senatore G, Carreras G, Taglieri C et al (2002) Catheter ablation of nodal re-entrant tachycardia with LocaLisa navigation system. Europace 3[Suppl A]:A239Google Scholar
  9. 9.
    Senatore G, Carreras G, Taglieri C et al (2002) Catheter ablation of atrial flutter with LocaLisa navigation system. Europace 3[Suppl A]:A240Google Scholar
  10. 10.
    Molenschot M, Ramanna H, Hoorntje T et al (2001) Catheter ablation of incisional atrial tachycardia using a novel mapping system: LocaLisa. Pacing Clin Electrophysiol 24:1616–1622PubMedCrossRefGoogle Scholar
  11. 11.
    Wittkampf F, Loh P, Derksen R et al (2002) Real-time, three dimensional, non-fluoroscopic localization of the Lasso catheter. J Cardiovasc Electrophysiol 13:630PubMedCrossRefGoogle Scholar
  12. 12.
    Macle L, Jaïs P, Shah D et al (2000) Pulmonary vein disconnection guided by the LocaLisa system. Circulation 102[Suppl 5]:560Google Scholar
  13. 13.
    Wever EFD, Elvan A, Ramanna H et al (1999) Catheter ablation of ventricular tachycardia in patients with structural heart disease using a nonfluoroscopic localization system (Localisa). Pacing Clin Electrophysiol 22, 4-II:P734Google Scholar

Copyright information

© Springer-Verlag Italia 2003

Authors and Affiliations

  • F. Atienza
    • 1
  • J. Almendral
    • 1
  • A. Arenal
    • 1
  • E. G. Torrecilla
    • 1
  • J. Jiménez
    • 1
  • M. Ortiz
    • 1
  1. 1.Electrophysiology Laboratory, Cardiology DepartmentHospital General Universitario Gregorio MarañónMadridSpain

Personalised recommendations