The Nexfin Monitor — A Totally Non-Invasive Cardiac Output Monitor

  • A. Perel
  • W. Wesselink
  • J. Settels

Abstract

The Nexfin HD monitor (BMEYE, Amsterdam, The Netherlands; http://www.bmeye.com), is a device that measures cardiac output (CO) continuously by an inflatable finger cuff, which is the only interface with the patient. The Nexfin HD measures continuous CO by combining continuous blood pressure (BP) monitoring and a novel pulse contour method (Nexfin CO-Trek) based on the systolic pressure area and a physiological three-element Windkessel model individualised for each patient. The parameters that are measured by the Nexfin HD include continuous BP (systolic, diastolic, mean), heart rate, continuous cardiac output (CCO), stroke volume (SV), systemic vascular resistance (SVR) and an index of left ventricular contractility (dp/dt).

Keywords

Cardiac Output Pulmonary Artery Catheter Pulse Contour Continuous Cardiac Output Continuous Blood Pressure 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Wo CCJ et al (1993) Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness Crit Care Med 21:218Google Scholar
  2. 2.
    Meregalli A, Oliveira RP, Friedman G (2004) Occult hypoperfusion is associated with increased mortality in hemodynamically stable, high-risk, surgical patients. Critical Care 8:R60–R65PubMedCrossRefGoogle Scholar
  3. 3.
    Veale WN Jr, Morgan JH, Beatty JS et al (2005) Hemodynamic and pulmonary fluid status in the trauma patient: are we slipping? Am Surg 71:621–625PubMedGoogle Scholar
  4. 4.
    Camporota L, Beale R (2010) Pitfalls in haemodynamic monitoring based on the arterial pressure waveform. Critical Care 14:124PubMedCrossRefGoogle Scholar
  5. 5.
    Wesseling KH, de Wit B, Weber JA, Smith NT (1983) A simple device for continuous measurement of cardiac output. Adv Cardiovasc Phys 5:16–52Google Scholar
  6. 6.
    Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Applied Physiol 74(5):2566–2573Google Scholar
  7. 7.
    Jansen JRC, Schreuder JJ, Mulier JP et al (2001) A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 87:212–222PubMedCrossRefGoogle Scholar
  8. 8.
    De Wilde RBP, Schreuder JJ, van den Berg PCM, Jansen JR (2007) An evaluation of cardiac output by five pulse contour techniques during cardiac surgery. Anaesthesia 62:760–768PubMedCrossRefGoogle Scholar
  9. 9.
    De Wilde RBP, Geerts BF, Cui J et al (2009) Performance of three minimally invasive cardiac output monitoring systems. Anaesthesia 64:762–769PubMedCrossRefGoogle Scholar
  10. 10.
    Stover JF, Stocker R, Lenherr R et al (2009) Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 9:6PubMedCrossRefGoogle Scholar
  11. 11.
    Bundgaard-Nielsen M, Ruhnau B, Secher NH, Kehlet H (2007) Flow-related techniques for preoperative goal-directed fluid optimization. Br J Anaesth 98:38–44PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag Italia 2011

Authors and Affiliations

  • A. Perel
  • W. Wesselink
  • J. Settels

There are no affiliations available

Personalised recommendations