Hemodynamics in Standard Cardiac Pacing

  • Milos Taborsky
Conference paper


The first rate-responsive pacing systems were introduced by Center [1] and Lagergren [2] in 1964–1966. Both systems used P waves, which were detected with an atrial electrode positioned by thoracotomy or mediastinoscopy to trigger the ventricular pacing after a short delay. A comparison of the acute data with VVI pacing showed that the cardiac index increased by 10–30%. Despite these promising data, atrioventricular (AV) synchronous pacemakers were not widely used until the late 1970s.


Left Bundle Branch Block Ventricular Pace Complete Heart Block Atrial Contraction Sick Sinus Syndrome 


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.


  1. 1.
    Center S, Nathan D, Wu CY et al (1964) Two years of clinical experience with the synchronous pacemaker. J Thorac Cardiovasc Surg 48:513–526PubMedGoogle Scholar
  2. 2.
    Lagergren H, Johansson L, Karlof J et al (1966) Atrial-triggered pacemaking without thoracotomy. Acta Chir Scand 132: 678–695Google Scholar
  3. 3.
    Karlöf I (1975) Hemodynamics effect of atrial triggered versus fixed rate pacing at rest and during exrecise in complete heart block. Acta Med Scand 197:195–210PubMedGoogle Scholar
  4. 4.
    Kruse I, Bevegård S, Ovenfors CO et al (1982) A comparison of acute and long-term hemodynamics effects of ventricular inhibited and atrial synchronous pacing. Circulation 65:846–855PubMedGoogle Scholar
  5. 5.
    Kristensson B, Arnman K, Ryden L et al (1985) The hemodynamic importance of atrioventricular synchrony and rate increase at rest and during exercise. Eur Heart J 6:773–778PubMedGoogle Scholar
  6. 6.
    Perhsson SK (1983) Influence of heart rate and atrioventricular synchrony on maximal work tolerance in patients treated with artificial pacemakers. Acta Med Scand 214:311–315CrossRefGoogle Scholar
  7. 7.
    Benchimol A, Li YB, Simone EG (1964) Cardiovascular dynamics in complete heart block at various heart rates. Circulation 30:542–543PubMedGoogle Scholar
  8. 8.
    Sowton E (1964) Hemodynamic studies in patients with artificial pacemakers. Br Heart 26:737–746CrossRefGoogle Scholar
  9. 9.
    Videem JS, Juany SK, Bazgan ID et al (1986) Hemodynamic comparison of ventricular pacing, atrioventricular sequential pacing and atrial synchronous ventricular pacing using radionuclide ventriculography. Am J Car diol 57:1305–1308CrossRefGoogle Scholar
  10. 10.
    Norlander R, Pehrsson SK, Astrom H et al (1987) Myocardial demands of atrialtriggered versus fixed-rate ventricular pacing in patients with complete heart block. Pacing Clin Electrophysiol 10:1154–1159CrossRefGoogle Scholar
  11. 11.
    Leclercq C, Gras D, Le Helloco A et al (1995) Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing. Am Heart J 129:1133–1141PubMedCrossRefGoogle Scholar
  12. 12.
    Rowe GG, Stenlund RR, Thomsen JH et al (1969) Coronary and systemic hemodynamic effects of cardiac pacing in man with complete heart block. Circulation 40:839–845Google Scholar
  13. 13.
    Brockman SK (1965) Cardiodynamics of complete heart block. Am J Cardiol 16:72–83PubMedCrossRefGoogle Scholar
  14. 14.
    Vos MA, de Groot SH, Verduyn SC et al (1998) Enhanced susceptibility for acquired torsade de pointes arrhythmias in the dog with chronic, complete atrio-ventricular block is related to cardiac hypertrophy and electrical remodeling. Circulation 98:1125–1235PubMedGoogle Scholar
  15. 15.
    Brockman SK, Stoney WS (1969) Congestive and heart failure and cardiac output in heart block and during pacing. Ann NY Acad Sci 167:534–545PubMedCrossRefGoogle Scholar
  16. 16.
    Janousek J, Tomek V, Chaloupecky V et al (2004) Dilated cardiomyopathy associated with dual-chamber pacing in infants: improvement through either left ventricular cardiac resynchronization or programming the pacemaker off allowing intrinsic normal conduction. J Cardiovasc Electrophysiol 15:470–474PubMedCrossRefGoogle Scholar
  17. 17.
    Tantengco MV, Thomas RL, Karpawich PP (2001) Left ventricular dysfunction after long-term right ventricular apical pacing in the young. J Am Coll Cardiol 37:2093–2100PubMedCrossRefGoogle Scholar
  18. 18.
    Thambo JB, Bordachar P, Garrigue S et al (2004) Detrimental ventricular remodeling in patients with congenital complete heart block and chronic right ventricular apical pacing. Circulation 110:3766–3772PubMedCrossRefGoogle Scholar
  19. 19.
    Peschar M, March AM, Verbenek X et al (2004) Site of right ventricular pacing determines left ventricular remodeling in patients with atrio-ventricular block. Heart Rhythm 1:245Google Scholar
  20. 20.
    Faerestrand S, Ohm O-J (1985) A time-related study of the hemodynamic benefit of atrioventricular synchronous pacing evaluated by Doppler echocardiography. Pacing Clin Electrophysiol 8:838–848PubMedCrossRefGoogle Scholar
  21. 21.
    Bowman AW, Kovacs SJ (2004) Left atrial conduction volume is generated by deviation from the constant volume state of the left heart: a combined MRI-echocardiographic study. Am J Physiol Heart Circ 286:H2416–H2424CrossRefGoogle Scholar
  22. 22.
    Mehta D, Gilmour S, Ward DE et al (1989) Optimal atrioventricular delay at rest and during exercise in patients with dual chamber pacemakers: a non-invasive assessment by continuous wave Doppler. Br Heart J 61:161–166PubMedCrossRefGoogle Scholar
  23. 23.
    Ritter P, Dib JC, Mahaut V et al (1995) New method for determining the optimal atrio-ventricular delay in patients paced in DDD mode for complete atrioventricular block. Pacing Clin Electrophysiol 18 (Part II):237CrossRefGoogle Scholar
  24. 24.
    Sutton R (1992) The atrioventricular interval: what considerations influence its programming? Eur Cardiac Pacing Electrophysiol 3:169Google Scholar
  25. 25.
    Dupot WD, Plummer WD Jr (1998) Power and sample size calculations for studies involving linear regression. Control Clin Trials 19:589–601CrossRefGoogle Scholar
  26. 26.
    Bedotto JB, Grayburn PA, Black WH et al (1990) Alterations in left ventricular relaxation during atrioventricular pacing in humans. J Am Coll Cardiol 15:658–664PubMedCrossRefGoogle Scholar
  27. 27.
    Tanabe A, Mohri T, Ohga M et al (1990) The effects of pacing-induced left bundle branch block on left ventricular systolic and diastolic performances. Jpn Heart J 31:309–317PubMedGoogle Scholar
  28. 28.
    Wiggers CJ (1925) The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol 73:346–378Google Scholar
  29. 29.
    Kosovsky BD, Scherlag BJ, Samaro AN (1968) Re-evaluation of the atrial contribution to ventricular function. Am J Cardiol 21:518–524CrossRefGoogle Scholar
  30. 30.
    Nielsen JC, Andersen HR, Thomsen PEB et al (1998) Heart failure and echocardiographic changes during long-term follow-up of patients with sick-sinus syndrome randomized to single-chamber atrial or ventricular pacing. Circulation 97:987–995PubMedGoogle Scholar
  31. 31.
    Santini M, Alexidou G, Ansalone G et al (1990) Relation of prognosis in sick sinus syndrome to age, conduction defects and modes of permanent cardiac pacing. Am J Cardiol 65:729–735PubMedCrossRefGoogle Scholar
  32. 32.
    Andersen HR, Nielsen JC, Thomsen PEB et al (1997) Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick sinus syndrome. Lancet 350:1210–1216PubMedCrossRefGoogle Scholar
  33. 33.
    Sweeny MO, Hellkamp AS, Ellenbogen KA et al (2003) Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 107:2932–2937CrossRefGoogle Scholar
  34. 34.
    Wilkoff BL, Cook JR, Epstein AE et al (2002) Dual-chamber pacing or ventricular back-up pacing in patients with an implantable defibrillator. JAMA 288:3115–3123PubMedCrossRefGoogle Scholar
  35. 35.
    Verbenek X, Vernooy K, Pesar M et al (2002) Quantification of interventricular synchrony during LBBB and ventricular pacing. Am J Physiol 283:H1370–H1378Google Scholar
  36. 36.
    Liu L, Tockman B, Girouard S et al (2002) Left ventricular resynchronization therapy in a canine model of left bundle branch block. Am J Physiol 282:H2238–H2244Google Scholar
  37. 37.
    Hirzel HO, Senn M, Nuesch K et al (1984) Thalium-201 scintigraphy in complete left bundle branch block. Am J Cardiol 53:764–769PubMedCrossRefGoogle Scholar
  38. 38.
    Kaas DA, Chen CH, Curry C et al (1999) Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay. Circulation 99:1567–1573Google Scholar
  39. 39.
    Dekker AL, Phelps B, Dijkam A et al (2004) Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops. J Thorac Cardiovasc Surg 27:1642–1647Google Scholar
  40. 40.
    Rabkin SW, Mathewson FAL, Tate RB (1980) Natural history of left bundle-branch block. Br Heart 43:164–169CrossRefGoogle Scholar
  41. 41.
    Schneider JF, Thomas HE Jr, Sorlie P et al (1981) Comparative features of newly acquired left and right bundle branch block in general population. The Framingham Study. Am J Car diol 47:931–940CrossRefGoogle Scholar
  42. 42.
    Khoury D, McAlister H, Wilkoff B et al (1989) Continuous right ventricular volume assessment by catheter measurement of impedance for antitachycardia system control. Pacing Clin Electrophysiol 12:1918–1926PubMedCrossRefGoogle Scholar
  43. 43.
    Chirife R, Ortega DF, Salazar A (1993) Feasibility of measuring relative right ventricular volumes and ejection fraction with implantable rhythm control device. Pacing Clin Electrophysiol 16:1673–1683PubMedCrossRefGoogle Scholar
  44. 44.
    Gasparini M, Denis A, Mantica M et al (2001) Hemodynamic sensors: what clinical value do they have in heart failure. In: Raviele A (ed) Cardiac arrhythmias. Springer Verlag Italia, Milan, pp 576–585Google Scholar
  45. 45.
    Artur W, Kaye GC (2001) Clinical use of intracardiac impedance: current applications and future perspectives. Pacing Clin Electrophysiol 24 (Pt I):500–506CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Italia 2007

Authors and Affiliations

  • Milos Taborsky
    • 1
  1. 1.Cardiology DepartmentNa Homolce HospitalPragueCzech Republic

Personalised recommendations