Arterial waveform analysis to determine cardiovascular parameters

  • S. Scolletta
  • B. Biagioli
  • P. Giomarelli
Conference paper


Pulsatile pressure has been recorded routinely in human cardiovascular diagnostic laboratories, operating rooms and critical care units since the present generation started work, and pulsatile flow patterns are now used increasingly both invasively and noninvasively for the quantification of a number of cardiovascular parameters. However, it is a supreme paradox that modern physicians, almost without exception, while surrounded by twenty-first century aids to diagnosis and therapy, uses the arterial pulse only to assess systolic, diastolic and mean blood pressure and heart rate and rhythm, and takes no notice of the other information that the pulse is capable of imparting [1].


Fluid Responsiveness Pulse Pressure Variation Stroke Volume Variation Applanation Tonometry Pulse Contour 


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.


  1. 1.
    Nichols WW, O’Rourke MF (2005) McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. Hodder-Arnold, LondonGoogle Scholar
  2. 2.
    Bennet D (2005) Arterial pressure: a personal view. In: Pinsky MR, Payen D (eds) Functional hemodynamic monitoring. Springer, Berlin Heidelberg New York, pp 89–97CrossRefGoogle Scholar
  3. 3.
    Snellen HA (1980) EJ Marey and cardiology. Kookyer, RotterdamGoogle Scholar
  4. 4.
    Mahomed FA (1872) The physiological and clinical use of the sphygmograph. Med Times Gaz 1:62–64Google Scholar
  5. 5.
    Broadbent WH (1890) The pulse. Cassell, LondonGoogle Scholar
  6. 6.
    Kelly R, Hayward C, Avolio A et al (1989) Non-invasive determination of age-related changes in human arterial pulse. Circulation 80:1652–1659PubMedGoogle Scholar
  7. 7.
    Kemmotsu O, Ueda M, Otsuka H et al (1991) Arterial tonometry for non-invasive, continuous blood pressure monitoring during anesthesia. Anesthesiology 75:333–340PubMedCrossRefGoogle Scholar
  8. 8.
    Glasser SP, Arnett DK, McVeigh GE et al (1997) Vascular complianceand cardiovascular disease: a risk factor or a marker? Am J Hypertens 10:1175–1189PubMedCrossRefGoogle Scholar
  9. 9.
    Karamanoglu M, O’Rourke MF, Avolio AP et al (1993) An analysis of the relationship between central aortic and peripheral upper limb pressure wave in man. Eur Heart J 14:160–167PubMedGoogle Scholar
  10. 10.
    Wesseling KH, De Wit B, Weber JAP et al (1983) A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification. Adv Cardiol Phys 5(Suppl II):16–52Google Scholar
  11. 11.
    Wesseling KH, Jansen JRC, Settels JJ et al (1993) Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 74:2566–2573PubMedGoogle Scholar
  12. 12.
    Langewouters GJ, Wesseling KH, Goedhard WJA (1984) The static elastic properties of 45human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17:425–435PubMedCrossRefGoogle Scholar
  13. 13.
    Jansen JRC, Wesseling KH, Settels JJ et al (1990) Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur Heart J 11(Suppl I):26–32PubMedGoogle Scholar
  14. 14.
    Cecconi M, Wilson J, Rhodes A (2006) Pulse pressure analysis. In: Vincent JL (ed) Yearbook of intensive care and emergency medicine. Springer, Berlin Heidelberg New York, pp 176–184CrossRefGoogle Scholar
  15. 15.
    Della Rocca G, Costa MG, Pompei L et al (2002) Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 88:350–356PubMedCrossRefGoogle Scholar
  16. 16.
    Rodig G, Prasser C, Keyl C et al (1999) Continuous cardiac output measurement: pulse contour analysis versus thermodilution technique in cardiac surgical patients. Br J Anaesth 82:525–530PubMedGoogle Scholar
  17. 17.
    Rhodes A, Sunderland R (2005) Arterial pulse power analysis: the LiDCOTM-plus system. In: Pinsky MR, Payen D (eds) Functional hemodynamic monitoring. Springer, Berlin Heidelberg New York, pp 183–192CrossRefGoogle Scholar
  18. 18.
    Linton RAF, Band DM, Haire KM (1993) A new method of measuring cardiac output in man using lithium dilution. Br J Anesth 71:262–266CrossRefGoogle Scholar
  19. 19.
    Romano SM, Pistolesi M (2002) Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 30:1834–1841PubMedCrossRefGoogle Scholar
  20. 20.
    Giomarelli P, Biagioli B, Scolletta S (2004) Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 26:515–520PubMedCrossRefGoogle Scholar
  21. 21.
    Scolletta S, Romano SM, Biagioli B et al (2005) Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth 95:159–165PubMedCrossRefGoogle Scholar
  22. 22.
    Romano SM, Scolletta S, Olivotto I et al (2006) Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation. Perfusion 21:109–116PubMedCrossRefGoogle Scholar
  23. 23.
    Manecke GR (2005) Edwards Flo Trac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Rev Med Device 2:523–527CrossRefGoogle Scholar
  24. 24.
    Reuter DA, Goetz AE (2005) Arterial pulse contour analysis: applicability to clinical routine. In: Pinsky MR, Payen D (eds) Functional hemodynamic monitoring. Springer, Berlin Heidelberg New York, pp 175–182CrossRefGoogle Scholar
  25. 25.
    Sakka SG, Ruhl CC, Pfeiffer UJ et al (2000) Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med 26:180–187PubMedCrossRefGoogle Scholar
  26. 26.
    Michard F, Teboul JL (2000) Using heart-lung interaction to assess fluid responsiveness during mechanical ventilation. Crit Care 4:282–289PubMedCrossRefGoogle Scholar
  27. 27.
    Wiesenack C, Prasser C, Rodig G et al (2003) Stroke volume variation as an indicator of fluid responsiveness using arterial pulse contour analysis in mechanically ventilated patients. Anesth Analg 96:1254–1257PubMedCrossRefGoogle Scholar
  28. 28.
    Jardin F, Farcot JC, Gueret P (1983) Cyclic changes in arterial pulse during respiratory support. Circulation 83:266–227Google Scholar
  29. 29.
    Perel A, Pizov R, Cotev S (1987) Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 67:498–502PubMedCrossRefGoogle Scholar
  30. 30.
    Reuter DA, Kirchner A, Felbinger TW (2003) Usefulness of left ventricular stroke volume variations to assess fluid responsiveness in patients with reduced left ventricular function. Crit Care Med 31:1399–1404PubMedCrossRefGoogle Scholar
  31. 31.
    Tavernier B, Makhotine O, Lebuffe G (1998) Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:1313–1321PubMedCrossRefGoogle Scholar
  32. 32.
    Sonnenblick EH, Strohbeck JE (1977) Current concepts in cardiology. Derived indices of ventricular and myocardial function. N Engl J Med 296:978–982PubMedCrossRefGoogle Scholar
  33. 33.
    Perel A, Preisman S, Berkenstadt H (2005) Arterial pressure variation during positive-pressure ventilation. In: Pinsky MR, Payen D (eds) Functional hemodynamic monitoring. Springer, Berlin Heidelberg New York, pp 313–329CrossRefGoogle Scholar
  34. 34.
    Massumi RA, Mason DT, Zakauddin V et al (1973) Reversed pulsus paradoxus. N Engl J Med 289:1272–1275PubMedCrossRefGoogle Scholar
  35. 35.
    Pinsky MR (2003) Probing the limits of arterial pulse contour analysis to predict preload responsiveness. Anesth Analg 96:1245–1247PubMedCrossRefGoogle Scholar
  36. 36.
    Scolletta S, Romano SM, Maglioni E et al (2005) Left ventricular performance by PRAM during cardiac surgery. Intensive Care Med 31(Suppl 1):S157Google Scholar

Copyright information

© Springer-Verlag Italia 2007

Authors and Affiliations

  • S. Scolletta
    • 1
  • B. Biagioli
    • 1
  • P. Giomarelli
    • 2
  1. 1.Department of Cardiothoracic Anaesthesia and Intensive Care UnitUniversity of SienaItaly
  2. 2.Department of Anaesthesia and Intensive Care UnitUniversity of SienaItaly

Personalised recommendations