Abstract
This paper presents the improvement of reactive power and voltage in fourteen bus system using TCTC and STATCOM. Flexible AC transmission systems (FACTS) are the option to mitigate the problem of overloaded lines due to increased electric power transmission by controlling power flows. In this work, combined controller based on optimal power flow (OPF) with multiple objectives is derived in order to provide secure transmission and reduces transmission losses. Static compensator and thyristor-controlled tap changer are two such compensators belonging to FACTS devices are used in this work. The fourteen bus system with closed-loop-controlled STATCOM and TCTC is modeled and simulated.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Singh A, Surjan BS (2013) Power quality improvement using FACTS devices. Int J Eng Adv Technol 3(2):383–390
Debnath A, Nandi C (2013) Voltage profile analysis during fault with STATCOM. Intl J Comput Appl 72(11):16–22
Mehta Balwant K, Patel PJ (2013) Static voltage stability improvement in power system using STATCOM FACTS controller. J Inf Knowl Res Electr Eng 2(2):312–316
Tooraji HE, Abdolamir N (2013) Improving power quality parameters in AC transmission systems using unified power flow controller. Res J Recent Sci 2(4):84–90
Masdi H, Mariun N, Bashi SM, Mohamed A (2004) Design of a prototype D- STATCOM for voltage sag mitigation. In: IEEE conference, proceedings of power and energy, pp 45–49
Murali D, Rajaram M, Reka N (2010) Comparison of FACTS devices for power system stability enhancement. Int J Comput Appl 8(4):30–35
Quamruzzaman Md, Hossain Miraj R (2013) Voltage level and transient stability enhancement of a power system using STATCOM. Int J Adv Res Comput Sci Electron Eng 2(1):32–37
Ahmad A Prof, Shehzad A Dr, Shrivastava VB (2013) Power quality improvement using STATCOM in IEEE 30 bus system. Adv Electron Electr Eng 3(6): 727–732
Usha N, Vijaya Kumar M (2013) Enhancement of power quality in thirty bus system using ZSI based STATCOM. Int J Modern Eng Res 3(2):773–778
Murugan A, Nagarajan G, Sundarsingh Jebaseelan SD, Ravi CN (2014) Performance analysis of voltage profile, power, angle of injection using combined FACTS device. Int J Appl Eng 9(21):10303–10316. ISSN 0973-4562
Marlin S, Sundarsingh Jebaseelan SD, Padmanabhan B, Nagarajan G (2014) Power Quality improvement for thirty bus system using UPFC and TCSC. Indian J Sci Technol 7(9):1320–1324, Sept 2014
Sundarsingh Jebaseelan SD, Godwin Immanuel D (2014) Reactive power compensation using STATCOM with PID controller. Int J Appl Eng 9(21):11281–11290. ISSN 0973-4562
Kalai Murugan A, Rajaprabu R Dr (2013) Improvement of transient stability of power system using solid state circuit breaker. Am J Appl Sci 10(6):563–569
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer India
About this paper
Cite this paper
Sundarsingh Jebaseelan, S.D., Ravi, C.N., Nagarajan, G., Marlin, S. (2016). Closed-Loop Control of Facts Devices in Power System. In: Suresh, L., Panigrahi, B. (eds) Proceedings of the International Conference on Soft Computing Systems. Advances in Intelligent Systems and Computing, vol 397. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2671-0_34
Download citation
DOI: https://doi.org/10.1007/978-81-322-2671-0_34
Published:
Publisher Name: Springer, New Delhi
Print ISBN: 978-81-322-2669-7
Online ISBN: 978-81-322-2671-0
eBook Packages: EngineeringEngineering (R0)