Skip to main content

Seismic Response Control of Multi-story Asymmetric Building Installed with Dampers

  • Conference paper
  • First Online:

Abstract

The seismic response of linearly elastic, four-story asymmetric building installed with various dampers is investigated by numerical simulation study. The governing equations of motion are derived based on the mathematical model of asymmetric building. The seismic response of the system is obtained by numerically solving the equations of motion using state space method. The peak and root mean square response quantities obtained for the study are: lateral and torsional displacements, lateral and torsional accelerations, base shear, base torque as well as the control forces. The responses are obtained corresponding to the four real earthquake ground motions. The comparative performance is investigated for optimally designed dampers namely, semi-active magneto-rheological dampers, semi-active variable dampers, semi-active variable friction dampers, semi-active variable stiffness dampers and non-linear viscous dampers. The parametric studies are carried out to derive the optimum parameters for various control devices. It is observed that there exits an optimum parameters for various control devices such as to have optimum compromise between lateral-torsional displacement and acceleration response reduction as well as the damper capacity. Further, the implemented control devices are quite effective in reducing the lateral-torsional responses and the effectiveness is more in reducing the torsional responses as compared to the lateral responses.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Arturo TC, Jose LEC (2007) Torsional amplifications in asymmetric base-isolated structures. Eng Struct 29(2):237–247

    Article  Google Scholar 

  2. Jangid RS, Datta TK (1997) Performance of multiple tuned mass dampers for torsionally coupled system. Earthq Eng Struct Dyn 26(3):307–317

    Article  Google Scholar 

  3. Singh MP, Singh S, Moreschi LM (2002) Tuned mass dampers for response control of torsional buildings. Earthq Eng Struct Dyn 31(4):749–769

    Article  Google Scholar 

  4. De La Llera JC, Almazan JL (2003) An experimental study of nominally symmetric and asymmetric structures isolated with the FPS. Earthq Eng Struct Dyn 32(6):891–918

    Article  Google Scholar 

  5. Chi Y, Sain MK, Pham KD, Spencer BF Jr (2000) Structural control paradigms for an asymmetric building. In: Proceedings of the 8th ASCE specialty conference on probabilistic mechanics and structural reliability, PMC2000-152, University of Notre Dame, Notre Dame, Indiana, July 2000

    Google Scholar 

  6. Yoshida O, Dyke SJ (2005) Response control of full-scale irregular buildings using magnetorheological dampers. J Struct Eng (ASCE) 131(5):734–742

    Google Scholar 

  7. Li HN, Li XL (2009) Experiment and analysis of torsional seismic responses for asymmetric structures with semi-active control by MR dampers. Smart Mater Struct 18(7):075007

    Article  Google Scholar 

  8. Shook DA, Roschke PN, Lin PY, Loh CH (2009) Semi-active control of torsionally-responsive structure. Eng Struct 31(1):57–68

    Article  Google Scholar 

  9. De La Llera JC, Chopra AK (1995) A simplifled model for analysis and design of asymmetric-plan buildings. Earthq Eng Struct Dyn 24(4):573–594

    Article  Google Scholar 

  10. He WL, Agrawal AK, Mahmoud K (2001) Control of seismically excited cable-stayed bridge using resetting semiactive stiffness dampers. J Bridge Eng (ASCE) 6(6):376–384

    Article  Google Scholar 

  11. Yang JN, Kim JH, Agrawal AK (2000) Resetting semiactive stiffness damper for seismic response control. J Struct Eng (ASCE) 126(12):1427–1433

    Article  Google Scholar 

  12. Lu LY (2004) Predictive control of seismic structures with semi-active friction dampers. Earthq Eng Struct Dyn 33(5):647–668

    Article  Google Scholar 

  13. Ruangrassamee A, Kawashima K (2001) Experimental study on semi-active control of bridges with use of magnetorheological damper. J Struct Eng 47A:639–650

    Google Scholar 

  14. Spencer BF Jr, Dyke SJ, Sain MK, Carlson JD (1997) Phenomenological model for magnetorheological dampers. J Eng Mech (ASCE) 123(3):230–238

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Snehal V. Mevada .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer India

About this paper

Cite this paper

Mevada, S.V. (2015). Seismic Response Control of Multi-story Asymmetric Building Installed with Dampers. In: Matsagar, V. (eds) Advances in Structural Engineering. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2193-7_101

Download citation

  • DOI: https://doi.org/10.1007/978-81-322-2193-7_101

  • Published:

  • Publisher Name: Springer, New Delhi

  • Print ISBN: 978-81-322-2192-0

  • Online ISBN: 978-81-322-2193-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics