Abstract
The strengthening of concrete structures with fibre reinforced polymer (FRP) composites has existed since last two decade. The most common way to strengthen structures is in bending, shear and retrofitting of columns. FRP offers excellent corrosion resistance to environmental agents as well as the advantages of high stiffness-to-weight ratio and strength-to-weight ratio. This paper presents an experimental investigation on strain analysis of a reinforced concrete (RC) T-beams strengthened in shear with U-wrapped glass fibre reinforced polymer (GFRP) sheet. A total of eighteen (18) full scale simply supported RC T-beams are tested. Nine beams are used as control beam with three different stirrups spacing (transverse steel) without GFRP wrap and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in U-configuration for each type of stirrup spacing. This study focuses on strain analysis of U-wrapped GFRP sheet, transverse steel reinforcement and longitudinal steel reinforcement. It is observed that the strain in the U-wrapped GFRP sheet is higher in the specimens strengthened with one layer of GFRP, as compared to two and three layers in all the series. The stiffness of GFRP sheet is indirectly proportional to the strain.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Pellegrino C, Modena C (2002) Fiber reinforced polymer shear strengthening of reinforced concrete beams with transverse steel reinforcement. J Compos Constr 6(2):104–111
Chaallal O, Shahawy M, Hassan M (2002) Performance of reinforced concrete T-girders strengthened in shear with carbon fiber-reinforced polymer fabric. ACI Struct J 99(3):335–343
Bousselham A, Chaallal O (2006) Effect of transverse steel and shear span of the performance of RC beams strengthened in shear with CFRP. Compos B 37:37–46
Bousselham A, Chaallal O (2008) Mechanisms of shear resistance of concrete beams strengthened in shear with externally bonded FRP. J Compos Constr 12(5):499–512
Panda KC, Bhattacharyya SK, Barai SV (2010) Shear behaviour of reinforced concrete T-beams with U-bonded glass fibre reinforced plastic sheet. Indian Concr J 84(10):61–71
Panda KC, Bhattacharyya SK, Barai SV (2012) Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet. Steel Compos Struct Int J 12(2):149–166
Panda KC, Bhattacharyya SK, Barai SV (2013) Effect of transverse steel on the performance of RC T-beams strengthened in shear zone with GFRP sheet. Constr Build Mater 41:79–90
Indian Standard (2000) Plain and reinforced concrete code of practice IS 456: 2000, India, 100Â p
ACI Committee 440 (2002) Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2R-02). American Concrete Institute, Farmington Hills, Michigan, USA, 45Â p
Acknowledgments
The authors express their sincere gratitude to the structural engineering laboratory, IIT Kharagpur, India, for their technical support and material support for the experiment.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer India
About this paper
Cite this paper
Panda, K.C., Bhattacharyya, S.K., Barai, S.V. (2015). Strain Analysis of RC T-beams Strengthened in Shear with Variation of U-wrapped GFRP Sheet and Transverse Steel. In: Matsagar, V. (eds) Advances in Structural Engineering. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2187-6_154
Download citation
DOI: https://doi.org/10.1007/978-81-322-2187-6_154
Publisher Name: Springer, New Delhi
Print ISBN: 978-81-322-2186-9
Online ISBN: 978-81-322-2187-6
eBook Packages: EngineeringEngineering (R0)