Abstract
The objective of the electric utility is to deliver sinusoidal voltage at fairly constant magnitude throughout their system. As the load is more nonlinear, complexities also increase since these nonlinear loads produce harmonic currents. These harmonic currents result in voltage and current distortions that can adversely impact the system performance in different ways. With the increase in harmonic producing loads at the installation, severity to address the issue also increases. As an impact of these phenomena, two important concepts are to be borne in mind with regard to power system harmonics. They are harmonic current generated due to nonlinear loads such as computers and printers, and the second is the effect of harmonic currents [1, 2]. In this work, the harmonics generated due to computer and printer is analyzed using power quality analyzer and harmonics are eliminated using wavelet transform.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Ellis RG Power system harmonics, a reference guide to causes, effects and corrective measures. http://literature.rockwellautomation.com/idc/groups/literature/documents/wp/mvb-wp011_-en-p.pdf
Chandra A, Al-Haddad K, Singh B (1998) Harmonic elimination, reactive power compensation and load balancing in 3 phase 4 wire electric distribution system supplying nonlinear loads. Electr Power Syst Res 44(2):93–100
Blooming TM, Carnovale DJ (2007) Application of IEEE Std 519-1992 harmonic limits. IEEE IAS Atlanta section, September 17
Kim SS, Enjeti PN (2002) A new hybrid active power filter (APF) topology. IEEE Trans Power Electron 17(1):48–54
Attia HA, El-Metwally M, Fahmy OM (2010) Harmonic distortion effects and mitigation in distribution systems. J Am Sci 6:173–183
Baggini A (ed) (2002) Wavelet network based detection and classification of transients, Handbook of power quality. University of Bergamo, Italy 14PSCC, SEVILLA, 24–28 June 2002
Angrisani L, Daponte PD, Apuzzo M, Testa A (1998) A measurement method based on the wavelet transform for power quality analysis. IEEE Trans Power Deliv 13(4):990–998
Basu M, Basu B (2007) Analysis of power quality (PQ) signals by continuous wavelet transform 2007. IEEE power electronics specialists conference, June 2007
Vidya HA, Krishnan V (2009) Some investigations on denoising of partial discharge signals using wavelet transforms. PhD Thesis, VTU, Belgaum
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer India
About this paper
Cite this paper
Vidya, H.A., Priyashree, S., Venkatesha, K. (2013). Harmonic Analysis and its Elimination in Nonlinear Loads Using Wavelet Transform. In: Chakravarthi, V., Shirur, Y., Prasad, R. (eds) Proceedings of International Conference on VLSI, Communication, Advanced Devices, Signals & Systems and Networking (VCASAN-2013). Lecture Notes in Electrical Engineering, vol 258. Springer, India. https://doi.org/10.1007/978-81-322-1524-0_47
Download citation
DOI: https://doi.org/10.1007/978-81-322-1524-0_47
Published:
Publisher Name: Springer, India
Print ISBN: 978-81-322-1523-3
Online ISBN: 978-81-322-1524-0
eBook Packages: EngineeringEngineering (R0)