Skip to main content

Noninvasive Diagnosis of the Artery of Adamkiewicz

  • Conference paper
Book cover Advances in Understanding Aortic Diseases

Summary

It is important to assess the artery of Adamkiewicz before repair of the thoraco abdominal aorta. Several studies have demonstrated the feasibility and advantages of noninvasive assessment of the artery of Adamkiewicz with MR angio graphy and CT angiography. Recent advanced in MR and CT angiography have led to changes in the detectability of this artery. In our experience, CT and/ or MR angiography are comparable or superior to conventional angiography in the evaluation of the artery of Adamkiewicz. CT and MR angiography can also diagnose the various types of the collateral circulations. MR angiography is superior for depiction of the artery of Adamkiewicz, especially when it arises from the false lumen of a dissecting aneurysm. CT angiography has a wide field of view and allows depiction of significant collateral pathways associated with internal thoracic artery and intercostals arteries. For the identification of the artery of Adamkiewicz, it is very important to distinguish between the artery and a vein.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Coselli JS, LeMaire SA, Miller CC 3rd, et al (2000) Mortality and paraplegia after thoraco-abdominal aortic aneurysm repair: a risk factor analysis. Ann Thorac Surg 69:409–414.

    Article  PubMed  CAS  Google Scholar 

  2. Estrera AL, Miller CC 3rd, Huynh TT, et al (2001) Neurologic outcome after thoracic and thoracoabdominal aortic aneurysm repair. Ann Thorac Surg 72:1225–1231.

    Article  PubMed  CAS  Google Scholar 

  3. Cambria RP, Clouse WD, Davison JK, et al (2002) Thoracoabdominal aneurysm repair: results with 337 operations performed over a 15-year interval. Ann Surg 236:471–479.

    Article  PubMed  Google Scholar 

  4. Heinemann MK, Brassel F, Herzog T, et al (1998) The role of spinal angiography in operations on the thoracic aorta: myth or reality? Ann Thorac Surg 65:346–351.

    Article  PubMed  CAS  Google Scholar 

  5. Kieffer E, Fukui S, Chiras J, et al (2002) Spinal cord arteriography: a safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy. J Vasc Surg 35:262–268.

    Article  PubMed  Google Scholar 

  6. Williams GM, Roseborough GS, Thomas HW, et al (2004) Preoperative selective intercos-tals angiography in patients undergoing thoracoabdominal aneurysm repair. J Vasc Surg 39:314–320.

    Article  PubMed  Google Scholar 

  7. Yoshioka K, Niinuma H, Ohira A, et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215–1225.

    Article  PubMed  Google Scholar 

  8. Takase K, Sawamura Y, Igarashi K, et al (2002) Demonstration of the artery of Adamkiewicz at multi-detector row helical CT. Radiology 223:39–45.

    Article  PubMed  Google Scholar 

  9. Yamada N, Takamiya M, Kuribayashi S, et al (2000) MRA of the Adamkiewicz artery: a preoperative study for thoracic aortic aneurysm. J Comput Assist Tomogr 24:362–368.

    Article  PubMed  CAS  Google Scholar 

  10. Hyodoh H, Kawaharada N, Akiba H, et al (2005) Usefulness of preoperative detection of artery of Adamkiewicz with dynamic contrast-enhanced MR angiography. Radiology 236:1004–1009.

    Article  PubMed  Google Scholar 

  11. Yoshioka K, Niinuma H, Kawakami T, et al (20005) Three-dimensional demonstration of the artery of Adamkiewicz with contrast-enhanced magnetic resonance angiography. Ann Thorac Surg 79:1785.

    Article  Google Scholar 

  12. Yoshioka K, Niinuma H, Ohira A, et al (2004) Three-dimensional demonstration of the artery of Adamkiewicz by multidetector-row computed tomography. Ann Thorac Surg 78:719.

    Article  PubMed  Google Scholar 

  13. Yoshioka K, Niinuma H, Ehara S, et al (2006) MR angiography and CT angiography of the artery of Adamkiewicz: state of the art. Radiographics 26:S63–73.

    Article  PubMed  Google Scholar 

  14. Yoshioka K, Niinuma H, Ogino Y, et al (2006) Three-dimensional demonstration of the collateral circulation to the artery of Adamkiewicz with 16-row multislice computed tomography. Ann Thorac Surg 81:749.

    Article  PubMed  Google Scholar 

  15. Yoshioka K, Niinuma H, Kawazoe K, et al (2005) Three-dimensional demonstration of the collateral circulation to the artery of Adamkiewicz via internal thoracic artery with 16-row multi-slice CT. Eur J Cardiothorac Surg 28:492.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer

About this paper

Cite this paper

Yoshioka, K., Tanaka, R., Ehara, S. (2009). Noninvasive Diagnosis of the Artery of Adamkiewicz. In: Kazui, T., Takamoto, S. (eds) Advances in Understanding Aortic Diseases. Springer, Tokyo. https://doi.org/10.1007/978-4-431-99237-0_4

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-99237-0_4

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-99236-3

  • Online ISBN: 978-4-431-99237-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics