Advertisement

High-Resolution Measurement of Pulse Wave Velocity for Evaluating Local Elasticity of Arterial Wall in Early-Stage Arteriosclerosis

  • Hiroshi Kanai
Conference paper

Abstract

In order to diagnose cardiovascular system based on acoustic characteristics of the heart muscle or aortic wall, it is necessary to measure small vibrations on these walls [1]. However, the amplitude of the cardiac motion is very large during one beat period. Thus, it is very difficult for previously proposed methods or standard ultrasonic diagnosis systems to measure these small vibration signals. We have proposed, therefore, a new method to track accurately object motion, and by applying the method to the aortic wall or heart wall, small vibrations of these surfaces can be observed.

Keywords

Pulse Wave Velocity Propagation Velocity Aortic Wall Vibration Signal Acoustic Characteristic 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Kanai H, Chubachi N, Kido K, Koiwa Y, Takagi T, Kikuchi J, Takishima T (1992) A New Approach to Time Dependent AR Modeling of Signals and Its Application to Analysis of the Fourth Heart Sound. IEEE Transactions on Signal Processing 40:1198–1205CrossRefGoogle Scholar
  2. 2.
    Kanai H, Satoh H, Hirose K, Chubachi N (1993) A New Method for Measuring Small Local Vibrations in the Heart Using Ultrasound. IEEE Transactions on Biomedical Engineering 40:1233–1242PubMedCrossRefGoogle Scholar
  3. 3.
    Kanai H, Kawabe K, Takano M, Murata R, Chubachi N, Koiwa Y (1994) New Method for Evaluating Local Pulse Wave Velocity by Measuring Vibrations on Arterial Wall. IEE Electronics Letters 30:534–536CrossRefGoogle Scholar
  4. 4.
    Kanai H, Satoh H, Chubachi N, Koiwa Y (1994) Noninvasive Measurement of Small Local Vibrations in the Heart or Aortic Wall. Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Vol.16, 7.1–1Google Scholar
  5. 5.
    Takano M, Kanai H, Chubachi N, Koiwa Y, Tezuka F, Takahashi M (1994) A Study on Propagation Velocity of Small Vibrations on Aortic Wall. Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Vol. 16, 7.1–5Google Scholar
  6. 6.
    Murata R, Kanai H, Chubachi N, Koiwa Y (1994) Measurement of Local Pulse wave Velocity on Aorta for Noninvasive Diagnosis of Arteriosclerosis. Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Vol. 16, 7.1–6Google Scholar