Skip to main content

Biomechanical Advances in Total Hip Replacement

  • Chapter
Biomechanics in Orthopedics

Summary

Cemented hip arthroplasty is one of the most successful procedures of modern surgery. However, attempts to extend this procedure to younger and more active individuals using cemented or cementless methods of fixation have met with mixed success. Cementless procedures still have an unacceptable incidence of pain and limp at follow-up. These symptoms appear to be related to the presence of localized areas of instability of the stem/bone interface secondary to inadequate proximal or distal fixation. In addition, an alarming complication of some cementless prostheses is focal osteolysis which appears to arise from a foreign body reaction to particulate debris generated by motion between the implant and bone. Continuing advances in cementless arthroplasty will arise from a systematic approach to implant design leading to more anatomic stems, greater integration of implants and instruments, and increased attention to the impact of surgical technique on implant/bone fit and the stability of cementless fixation.

The results of cemented arthroplasty also continue to improve. Retrospective studies of retrieved implants have shown that the fundamental cause of aseptic loosening and focal osteolysis is fragmentation of the cement mantle. This complication can be minimized through use of implants specifically designed for cemented fixation, centralized within the medullary canal with proximal and distal centralizing devices which guarantee a minimum thickness of bone cement. In terms of the biomechanics of the hip joint itself, hip replacement can be enhanced yet further through greater attention to restorating the anatomic relationship between the femur and the acetabulum. This necessitates the use of femoral components which increased head offset and coordination of the position of the femoral head with the shape of the femoral stem.

In the acetabulum, cementless fixation has been particularly successful in the short term. However, dependable fixation of acetabular cups sometimes necessitates adjunctive the use of bone screws which has led to a small but serious incidence of neurovascular complications. The morbidity of screw fixation within the pelvis may be minimized if bicortical screw purchase is avoided and if screw placement is restricted to areas of thickest available bone.

Solutions are still awaited to many unsolved challenges in total hip replacement. These include increased wear-resistance of the articulating surfaces, a truly biocompatible implant/bone interface and greater retention of cortical bone in the presence of rigid component fixation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Huddleston HD (1988) Femoral lysis after cemented hip arthroplasty. J Arthroplasty 3: 285–297

    Article  PubMed  CAS  Google Scholar 

  2. Anthony PP, Gie GA, Howie CR, Ling RSM, Perkins RD (1990) Localised endosteal bone lysis in relation to soundly fixed femoral components of cemented tatal hip replacements: A possible mechanism. J Bone and Joint Surg 72B: 532

    Google Scholar 

  3. Maloney WJ, Jasty M, Burke DW, O’Connor DO, Zalenski EB, Bragdon C, Harris, WH (1989) Biomechanical and histologic investigation of cemented total hip arthroplasties: A study of autopsy-retrieved femurs after in vivo cycling. CORR 249: 129–140

    Google Scholar 

  4. Vives P, de Lestang M, Jarde O, Decoopman M (1987) Interest du contact direct entre la tige femorale et I’os diaphysaire dans les prostheses totales cimentees. Rev Chir Orthop [Suppl] 2: 218–220

    Google Scholar 

  5. Maloney WJ, Jasty M, Harris WH, Galante JO, Callaghan JJ (1990) Endosteal erosion in association with stable uncemented femoral components. JBJS 72A: 1025–1034

    CAS  Google Scholar 

  6. Noble PC, Tullos HS, Landon GC (1991) The optimum cement mantle for total hip replacement. American Academy of Orthopaedic Surgeons, Park Ridge, Illinois (Instructional Course Lectures, vol XL )

    Google Scholar 

  7. McNiece GM, Amstutz HC (1976) Finite element studies in hip reconstruction. In: Komi PV (ed) Proceedings of the 5th International Congress on Biomechanics, University Park Press, Baltimore, pp 339–405

    Google Scholar 

  8. Ahmed AM, Raab S, Miller JE (1984) Metal cement interface strength in cemented stem fixation. J Orthop Res 2: 105–118

    Article  PubMed  CAS  Google Scholar 

  9. Huiskes R (1980) Some fundamental aspects of human joint replacements: Analysis of stresses and heat conduction in bone-prosthesis structures. Acta Orthop Scand 185: 109–200

    Google Scholar 

  10. Krause WR, Krug WH, Miller JE (1982) Strength of cement-bone interface. Clin Orthop 163: 290–299

    PubMed  Google Scholar 

  11. Crowninshield RD, Tolbert JR (1983) Cement strain measurement surrounding well-fixed femoral component stems. J Biomed Mater Res 17 (5): 819–828

    Article  PubMed  CAS  Google Scholar 

  12. Noble PC, Scheller AD, Tullos HS, Levy RN, Turner RH (1987) Applied design criteria for total hip prosthesis. In: Stillwell T (ed) The art of total hip arthroplasty. Grune and Straton, Orlando, pp 51–68

    Google Scholar 

  13. Beckenbaugh RD, Ilstrup DM (1978) Total hip arthroplasty: A review of three hundred and thirty-three cases with long-term follow-up. J Bone Joint Surg [Am] 60: 306

    Google Scholar 

  14. Ling RSM (1980) Prevention of loosening of total hip components. In: Mosby CV (ed) The hip Proceedings of the Eighth Open Scientific Meeing of the Hip Society. St Louis, pp 292–307

    Google Scholar 

  15. Miller J, Johnson JA (1987) Advances in cementing techniques in total hip arthroplasty. In: Stillwell T (ed) The art of total hip arthroplasty. Grune and Straton, Orlando, pp 277–291

    Google Scholar 

  16. Noble PC, Hammerman SM, Alexander JW, Green RB, Marltry JA, Tullos HS (1987) Innovations in cementing techniques in total hip replacement. Scientific Exhibit at the American Academy of Orthopaedic Surgeons 54th Annual Meeting, San Francisco

    Google Scholar 

  17. Davies JP, Jasty M, O’Connor DO, Burke DW, Harrigan TP, Harris WH (1989) The effect of centrifuging bone cement. JBJS 71B: 39–42

    CAS  Google Scholar 

  18. Burke DW, Gates EI, Harris WH (1984) Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement. JBJS, 66A: 1265–1273

    CAS  Google Scholar 

  19. Levy RN, Noble PC, Scheller A, Tullos HS, Turner R (1988) Prolonged fixation of cemented total hip replacement. Surgical Rounds for Orthopaedics, pp 15–22

    Google Scholar 

  20. Sarmiento A, Gruen TA (1985) Radiographic analysis of a low modulus titanium-alloy femoral total hip component. JBJS 67A: 48–56

    CAS  Google Scholar 

  21. Llinas A, Ebramzadeh E, McKellop H, Gogan W, Sarmiento A (1991) Femoral component size and position in cemented total hip prostheses. In: Proceedings of the American Academy of Orthopaedic Surgeons 58th Annual Meeting, Anabheim, California, March 7–12

    Google Scholar 

  22. Scheller A, Levy RN, Noble PC, Turner R (1989) A comparative analysis of total hip component position and cement technique. In: Proceedings of the American Academy of Orthopaedic Surgeons 56th Annual Meeting, Las Vegas, Nevada; February 9–14

    Google Scholar 

  23. Noble PC, Kamaric E, Alexander JW, Tullos HS (1989) What makes cementless implants work? Scientific Exhibit at the American Academy of Orthopedic Surgery 56th Annual Meeting, Las Vegas, Nevada

    Google Scholar 

  24. Noble PC, Alexander JW, Granbery ML, Granberry WM, Maltry JA, Tullos, HS (1988) The myth of “press-fit” in the proximal femur. Scientific Exhibit at the American Academy of Orthopaedic Surgeons 55th Annual Meeting, Atlanta, Georgia

    Google Scholar 

  25. Cook SD, Barrack RL, Thomas KA, Haddad RJ (1988) Quantitative analysis of tissue growth into human porous total hip components. J. Arthroplasty 3: 249–262

    Article  PubMed  CAS  Google Scholar 

  26. Noble PC (1990) Proximal Femoral Geometry and the design of cementless hip replacements. Orthop Rel Sci 1: 86–92

    Google Scholar 

  27. Noble PC, Alexander JW, Lindahl LJ, et al. (1988) The anatomic basis of femoral component design. Clin Orthop 235: 148–165

    PubMed  Google Scholar 

  28. Averill RG, Pachtman N, Jaffe WL (1980) A basic dimensional analysis of normal human proximal femora. In: Proceedings of the Eighth Annual Northeast Bioengineering Conference, Cambridge, Massachusetts, pp 352–356

    Google Scholar 

  29. Granberry ML, Noble PC, London GC, Tullos HS (1989) Factors influencing the clinical results of cementless femoral stems in total hip arthroplasty. In: Proceedings of the American Academy of Orthopaedic Surgeons 56th Annual Meeting, Las Vegas, Nevada; February 9–14

    Google Scholar 

  30. Ericksen MF (1979) Aging changes in the medullary cavity of the proximal femur in American blacks and whites. Am J Phys Anthropol 51: 563

    Article  PubMed  CAS  Google Scholar 

  31. Ruff CB, Hayes WC (1982) Subperiosteal expansion and cortical remodeling of the human femur and tibia with aging. Science 217: 945

    Article  PubMed  CAS  Google Scholar 

  32. Smith RW, Walker RR (1964) Femora expansion in aging woman: Implications for osteoporosis and fractures. Science 145: 156

    Google Scholar 

  33. Manley MT, Capello WN, Averill RG, Cohen R (1990) Effect of stem design parameters, stem fit, and bone quality on the torsional stability of femoral stems. In: Proceedings of the American Academy of Orthopaedic Surgeons 57th Annual Meeting, New Orleans, Louisiana, February 8–13

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1992 Springer-Verlag Tokyo

About this chapter

Cite this chapter

Noble, P.C. (1992). Biomechanical Advances in Total Hip Replacement. In: Niwa, S., Perren, S.M., Hattori, T. (eds) Biomechanics in Orthopedics. Springer, Tokyo. https://doi.org/10.1007/978-4-431-68216-5_4

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-68216-5_4

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-68218-9

  • Online ISBN: 978-4-431-68216-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics